Christopher Jarrett

Christopher Jarrett

Auto-generated profile, based on publicly available information

Christopher Jarrett

King's College Hospital NHS Foundation Trust, Physiotherapy, London, United Kingdom

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2017 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
CJC. Jarrett
C. Jarrett
AMA. J. McDaid
A. J. McDaid
A novel, cable-driven soft joint is presented for use in robotic rehabilitation exoskeletons to provide intrinsic, comfortable human-robot interaction. The torque-displacement characteristics of the soft elastomeric core contained within the joint are modeled. This knowledge is used in conjunction with a dynamic system model to derive a sliding mode controller (SMC) to implement low-level torque control of the joint. The SMC controller is experimentally compared with a baseline feedback-linearised proportional-derivative controller across a range of conditions and shown to be robust to un-modeled disturbances. The torque controller is then tested with six healthy subjects while they perform a selection of activities of daily living, which has validated its range of performance. Finally, a case study with a participant with spastic cerebral palsy is presented to illustrate the potential of both the joint and controller to be used in a physiotherapy setting to assist clinical populations.

25 March 2019 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
CJChristopher Jarrett
Christopher Jarrett
AMAndrew Mcdaid
Andrew Mcdaid
Safe and compliant physical human-robot interaction is a crucial consideration in exoskeleton design. This paper presents a model for an elastomer-based series elastic actuator (eSEA) and tests its feasibility to provide torque sensing as a haptic interface for soft, comfortable human-robot interaction in exoskeletons. The design of the eSEA and a model accounting for elasticity, rate-dependency and rate-independent hysteresis is presented. It is fitted with a worst-case RMS error of 1.6% of the full scale sensor range (FSR) of 4.5Nm and validated with both multi-tone sinusoid signals and new elastomers constructed from the same material. We then investigate the feasibility of using the sensor for sustained periods of time, with rehabilitation as a case study. An 8-9 hour experiment was designed to mimic how the eSEA might be used in a physiotherapy clinic. The model accuracy displayed some variation in these trials; however, this was limited to an RMS error of 3.3% of FSR. Additionally, any permanent changes appeared to be minor. The results hold promise for obtaining a reliable prediction of human-robot interaction torque in an exoskeleton, improving interaction between man and machine in various haptic applications.

1 February 2015
Verified
Conference Paper
Closed access
CJC. Jarrett
C. Jarrett
KPK. Perry
K. Perry
KSKarl Stol
Karl Stol
The development of an on board vision-based path following system for a fixed-wing UAV is presented. The application is railway following and three path-following controllers have been investigated for their suitability for this task. The system is novel in that it includes all system components on board a lightweight and low-cost UAV. A vision system has been developed to characterise railway lines as first-order polynomials and relay this information to a flight controller. Its functionality was extended to provide information about the pixel distance between railway tracks, to be used to calculate the height of the plane above the railway. In simulation, the Non-Linear Guidance Law was found to be the controller that yielded the fastest settling times and least overshoot values; followed by the Vector Field method. A baseline PID method was the worst performing controller. Flight tests were performed to verify operation of the system but no conclusions could be drawn regarding controller performance.

1 July 2017 in Computers in Biology and Medicine
Verified
Journal Article
Closed access
VJVinura Jayaneththi
Vinura Jayaneththi
JVJ. Viloria
J. Viloria
LWL.G. Wiedemann
L.G. Wiedemann
CJC. Jarrett
C. Jarrett
AMA.J. McDaid
A.J. McDaid

14 March 2017 in Frontiers in Neuroscience
Verified
Journal Article
Open access
CJChristopher Jarrett
Christopher Jarrett
AMAndrew McDaid
Andrew McDaid
Motor learning is a critical component of the rehabilitation process; however, it can be difficult to separate the fundamental causes of learning deficit when physical impairment is a confounding factor. In this paper, a new technique is proposed to augment the residual ability of physically impaired patients with a robotic rehabilitation exoskeleton, such that motor learning can be studied independently of physical impairment. The proposed technique augments the velocity of an on-screen cursor relative to the restricted physical motion. Radial Basis Functions (RBFs) are used to both model velocity and derive a function to scale velocity as a function of workspace position. Two variations of the algorithm are presented for comparison. In a cross-over pilot study, healthy participants were recruited and subjected to a simulated impairment imposed by the cable-driven wrist exoskeleton. Participants then completed a sinusoidal tracking task, in which the algorithms were statistically shown to augment the cursor velocity in the impaired state such that it matched position-dependent velocities recorded in the healthy state. A kinematic task was then designed as a motor-learning case study and the algorithms were again statistically shown to allow participants to complete the task to the same standard when impaired as when healthy. The results of the pilot study provide motivation for further research into the use of this technique to augment the capabilities of real patients, thus providing a tool with which motor-learning can be studied in neurologically impaired populations. This could be used to give physiotherapists greater insight into underlying causes of motor learning deficits, consequently facilitating and enhancing subject-specific therapy regimes.

1 June 2019
Verified
Conference Paper
Closed access
CJChristopher Jarrett
Christopher Jarrett
AMAndrew Mcdaid
Andrew Mcdaid
This paper presents a model inversion procedure for a viscoelastic compliant element contained within a rotary series elastic actuator (SEA). Model inversion plays an important role in enabling accurate model-based control of physical human-robot interaction (HRI) with SEAs. If the compliant element of the SEA is elastomeric, analytically inverting its model is non-trivial due to the presence of complex non-linear terms. This paper applies an alternative inversion procedure, by coupling a partially analytical inverse model with a disturbance observer (DOB). Results of inverting without a DOB are given as a baseline and compared to the analytical inversion + DOB with two different types of filter. To quantify the accuracy of the inversion, the output of the inversion procedure is passed back through the forward model to identify the `actual setpoint', the signal that would be generated if the output of the inversion procedure was tracked accurately. The inversions for five desired torque signals are presented; in all cases, the root-mean square (RMS) error between the desired setpoint and actual setpoint is lower when the DOB inversion procedure is used, compared to the RMS error incurred when the DOB is omitted. The results suggest that the proposed inversion procedure provides an accurate and mathematically tractable inverse of the complex viscoelastic elastomer model.