Although solar drainback systems have been used for a long time, they are still generating questions regarding smooth functioning. This paper summarises publications on drainback systems and compiles the current knowledge, experiences, and ideas on the technology. The collective research exhibits a lack of scientific publications dedicated to the drainback technology, however a significant number of patents have been published, detailing innovative technical solutions towards improvements and reliability. Based on the evaluation of drainback hydraulics, a detailed classification of this technology has been developed, with a brief description of each hydraulic typology. The operating modes have been split into three stages: filling, operation, and draining, which have been studied separately. A difference in the minimal filling velocities for a siphon development in the solar loop has been discovered in various reports. Specific features of the operation mode have been described. For the draining, existing mechanisms to initiate the emptying process have been identified and categorised. Finally, state-of-the-art hydraulic components for drainback systems have been established, with emphasis on their requirements. Based on those findings, the authors suggest potential future research paths in order to fill the knowledge gap and disseminate the drainback technology.
The transition to a sustainable energy system requires the consideration of all available renewable heat sources. This study assesses the potential of wastewater and river heat for district heating networks in the federal state of Hesse, Germany, considering the seasonality of available heat and heat demand. Using standardised temperature and flow profiles for 443 wastewater treatment plants as well as interpolated river temperature and flow data for approx. 1,500 km of rivers, the study quantifies the heat extraction potential. By matching with heat demand profiles at daily resolution, based on forecast heat demand data for the year 2045, the long-term usable potential is determined. Possible heat network areas are identified based on the heat density indicator. For all building blocks with heat densities above 175 MWh/(ha·a), the usable heat potential amounts to 4.5 TWh/a for river heat pumps and 4.9 TWh/a for wastewater heat pumps. Applying a higher threshold of 415 MWh/(ha·a) reduces the potential to 1.3 TWh/a and 2.4 TWh/a, respectively. The usable potential of both sources together corresponds to 11 % to 28 % of Hesse's heating demand for space heating and domestic hot water. Using a new 1D energy balance model for an exemplary river it is shown that the heat extraction from the river is acceptable concerning cumulative cooling. The study provides municipalities with a comprehensive database that facilitates the incorporation of these underutilised heat sources into their mandatory heat planning. The methodology presented can be adapted to other regions.