Putu Agus Aditya Pramana

Putu Agus Aditya Pramana

Auto-generated profile, based on publicly available information

Putu Agus Aditya Pramana

Department of Electrical Engineering, Universitas Indonesia, Depok, Indonesia

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2022 in IEEE Access
Verified
Journal Article
Open access
PPPutu Agus Aditya Pramana
Putu Agus Aditya Pramana
RDRinaldy Dalimi
Rinaldy Dalimi
Large photovoltaic (PV) generations are vulnerable to thermal faults where the location is difficult to determine. The pre-existing thermal fault detection method (mostly manual visual inspection) is time-consuming and non-continuously monitoring. It may lead to more defects, such as degrading the faulted PV cell or putting the PV farm on fire. We propose a novel PV thermal fault monitoring and detection method using a catadioptric device (CD), which promises quick and continuous detection. In this paper, as an early stage in CD development, we focus on constructing a model involving some parameters to identify the object image formation. Then, through the model, a simulation case study of the PV farm monitoring proses was performed where the CD is ostensibly placed in front of the PV arrays. We variated the model parameters and selected the combination that resulted in a symmetrical and non-overlapped PV array image, which was then analyzed to see the sensor requirements of the CD. The results showed that the developed model could simulate PV image formation on CD with good validity. Also, the case result found that nine parameter combinations produce symmetrical and non-overlapped PV images where the image ratio is more affected by the camera position than the focal length. Finally, the minimum sensor requirement is determined by the center length of the farthest PV image to monitor all of the PV arrays.

3 February 2023 in IEEE Access
Verified
Journal Article
Open access
PPPutu Agus Aditya Pramana
Putu Agus Aditya Pramana
RDRinaldy Dalimi
Rinaldy Dalimi
Photovoltaic (PV) farms are subject to thermal faults that can degrade and reduce module efficiency. The currently used method of detecting thermal fault is time-consuming and hard to locate the fault position, especially in large PV areas. It can result in additional flaws, such as igniting the PV farm. We provide a new approach for monitoring and detecting PV thermal faults through a catadioptric device (CD) that offers fast and continual detection. As an early development stage, in this study, we concentrate on building a mathematical model that can determine the thermal fault coordinate based on two object images from different CD positions. The experiment then verifies the model, and the parameter variation is performed to find the coordinate prediction characteristic. Also, a case study simulation on large PV system monitoring was performed to figure out the thermal fault localization process. The result shows that the mathematical model can be used to determine the coordinate position of the thermal fault with acceptable measurement error. The parameter xk tends to affect the average measurement error of the coordinate prediction and the error gradient of each axes couple. Greater the xk , smaller measurement and gradient error can be achieved. In addition, the case study simulation result shows that the thermal fault position can be predicted with the worst PE of less than 10%, with a MAPE, MAE, and RMSE in a reasonable value. Also, the sensitivity pattern can be used for CD condition monitoring.

20 October 2020
Verified
Conference Paper
Closed access
KMK.G.H Mangunkusumo
K.G.H Mangunkusumo
MRMuhammad Ridwan
Muhammad Ridwan
PPP.A.A Pramana
P.A.A Pramana
AHA.S Habibie
A.S Habibie
Battery management system is very important for maintaining optimum battery performance and lifetime. One of the most important part of battery management system is the battery charging strategy. The conventional fast charging method combines the advantages and eliminates the disadvantage of constant current charging and constant voltage charging. In this experimental study, multistage fast charging strategy based on development of two-step charging strategy are proposed. Experimental result shows that multistage and two-step charging current followed the acceptable current curve and multistage charging strategy is 138s or 11.73% faster than faster than two- step charging strategy.

1 March 2021 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
KMK G H Mangunkusumo
K G H Mangunkusumo
JHJ Hartono
J Hartono
PPP A A Pramana
P A A Pramana
The significant development of plug-in electric vehicle (PEV) is a challenge for distribution networks. The PEV charger is a power electronic device that generates large amounts of power over a period of time to charge EV battery. In addition, the EV on board charger (OBC) also produces harmonics due to the process of converting AC grid voltage to DC voltage. Converter as OBCs main device is a source of harmonics which directly connected to the distribution network. In this study, harmonics from single OBC, multiple OBC and PEV penetration scenario were evaluated and compared with the SPLN standard D5.004-1: 2012. From the study results, THD injected to the distribution network is influenced by the percentage of the base load and PEV penetration. The worst possible condition is occurred under low load conditions while high PEV penetration happens. From the simulation results using the distribution network model especially in residential area, the low base load scenario (10.47%) and the high PEV penetration (90.01%) is generating TDD 6.59% and THDv 2.61%, respectively. Therefore, it is known that the harmonic effects generated by PEV charging to the distribution network still meet SPLN D5.004-1: 2012

25 April 2016 in MATEC Web of Conferences
Verified
Journal Article
Open access
PDF file
PPPutu Agus Aditya Pramana
Putu Agus Aditya Pramana
BMBuyung Sofiarto Munir
Buyung Sofiarto Munir

1 August 2013
Verified
Conference Paper
Closed access
PPPutu Agus Aditya Pramana
Putu Agus Aditya Pramana
DKDeddy Kurniadi
Deddy Kurniadi
PSParsaulian I. Siregar
Parsaulian I. Siregar
Modeling and simulation of coriolis mass flowmeter (CMF) is necessary to explore the dynamic characteristics. The knowledge of dynamic characteristics of CMF is useful for insvestigating the CMF performance on pulsation of fluctuation flow phenomena. Some researchers have studied the dynamic characteristic of CMF in very diverse level of complexity. In this work, a model of CMF for arcuate type was developed by some simple mechanical laws and some assumptions. We simulated and analyzed the CMF response for some typical fluctuation flow, based on the CMF parameters. We found that the steady state gain and dynamic response of CMF were depends on the CMF parameter such as radius of arcuate and diameter of tube.