Amer Abbas Mohammed

Amer Abbas Mohammed

Auto-generated profile, based on publicly available information

Amer Abbas Mohammed

Department of Operative Dentistry Al‐Mustansiriya University, Al‐Rusafa Baghdad Iraq

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

12 August 2025 in PLOS ONE
Verified
Journal Article
Open access
AMAmer A. Mohammed
Amer A. Mohammed
AAAhmed Ali
Ahmed Ali
FFFederico Foschi
Federico Foschi
FMFrancesco Mannocci
Francesco Mannocci
Aim: This study aimed to develop a modified gutta-percha (GP) multifunctional endodontic material by incorporating mesoporous calcium silicate nanoparticles (MCSNs) or silver-incorporated mesoporous calcium silicate nanoparticles (Ag-MCSNs) as bioactive nanoparticle fillers to enhance bioactivity, biomineralization, and radiopacity while achieving low cytotoxicity and improved antibacterial activity. Methodology: MCSNs and Ag-MCSNs were synthesized and incorporated into GP at concentrations of 1%, 5%, and 10% by weight. The chemical and structural characterization of the new GP materials was performed using Fourier-transform infrared spectroscopy (FTIR), X-ray diffraction (XRD), energy-dispersive spectrometry (EDS), and field emission-scanning electron microscopy (FE-SEM) to assess filler distribution. Biomineralization was evaluated using XRD, EDS, and scanning electron microscopy (SEM). Ion release, pH changes, MTT assays, and culture-based techniques were employed to assess bioactivity, biocompatibility, and antibacterial properties. Finally, radiopacity testing was conducted. Results: All samples of the newly developed GP exhibited uniform particle distribution within the GP matrix. Bioactivity and biomineralization tests revealed hydroxyapatite (HA) layer precipitation at 3, 7, 14, and 28 days, with maximum HA formation observed with prolonged immersion. Samples containing MCSNs or Ag-MCSNs created a weakly alkaline microenvironment initially, maintaining a suitable pH over time. All groups demonstrated non-cytotoxicity, with cell viability exceeding 70%. Antibacterial tests showed larger inhibition zones in all experimental groups compared to the control, with GP containing 10% MCSNs or Ag-MCSNs exhibiting the highest antibacterial activity, particularly Ag-MCSNs. Radiopacity tests indicated no significant difference between the experimental and control groups. Conclusion: Gutta-percha materials incorporated with 10% MCSNs or Ag-MCSNs demonstrated enhanced bioactivity, biomineralization, and antibacterial properties compared to the control GP, while maintaining suitable levels of biocompatibility in accordance with ISO 10993/2009 standards. The incorporation of Ag-MCSNs significantly improved antibacterial effects, particularly against Enterococcus faecalis, and increased radiopacity, making it a promising material for root canal therapy.

11 June 2026 in Romanian Journal of Stomatology
Verified
Journal Article
Open access
AAAbeer A. Abass
Abeer A. Abass
AMAmer A. Mohammed
Amer A. Mohammed
MAMustafa N. Abdulghani
Mustafa N. Abdulghani
Objectives. Apical extrusion of debris (AED) is clinically significant because it can contribute to postoperative pain and delayed periapical healing. This study aimed to provide a quantitative comparison of AED generated by four thermo-mechanically treated endodontic files with different kinematic motions: “EdgeFile X7, One Curve (OC), Wave One Gold (WOG), and R-motion (R-M). Material and methods. Forty mandibular first molars with mesiobuccal canal curvatures ranging from 5° to 20° were selected and randomly divided into four experimental groups (n = 10 per group) according to the instrumentation system used: continuous rotary motion (EdgeFile X7 and OC) and reciprocating motion (WOG and R-M). AED was collected in pre-weighed Eppendorf tubes, and the specimens were incubated for five days at 70°C. The net weight of extruded debris was determined by calculating the difference between the initial tube weight and the post-incubation tube weight. Statistical analysis was performed using one-way ANOVA followed by Tukey’s post hoc test, with the significance level set at p < 0.05. Results. All systems produced measurable AED. OC showed the lowest mean AED value, whereas WOG showed the highest mean AED value, with statistically significant differences observed among the groups (p < 0.001). Conclusions. Within the limitations of this in vitro study, reciprocating systems, particularly WOG, were associated with significantly greater AED than rotary systems.

11 October 2026 in Clinical and Experimental Dental Research
Verified
Journal Article
Open access
PDF file
AJAhmed Ali Jasim
Ahmed Ali Jasim
HAHuda Ahmed Abdullah
Huda Ahmed Abdullah
AMAmer Abbas Mohammed
Amer Abbas Mohammed
SASamah Fadhil Al‐Qazzaz
Samah Fadhil Al‐Qazzaz
MMMafaz Mahdi Mohsin
Mafaz Mahdi Mohsin
Objective: This in vitro study evaluated the color accuracy and image sharpness of common macro and zoom lenses on a full‐frame body and tested whether differences among macro‐lens brands are clinically meaningful. Materials and Methods: 26 VITA 3D‐Master shade tabs were each photographed three times under standardized, cross‐polarized conditions on a Nikon D610. Three macro lenses (Nikon 105 mm, Sigma 105 mm, and Tamron 90 mm) and four zoom lenses (Nikon 24–70 mm, Nikon 24–120 mm, Sigma 24–70 mm, and Nikon 24–85 mm) were compared. RAW files were converted to CIELAB; reference L * a * b * values were obtained with a 45°/0° spectroradiometer under D65. Color difference (ΔEab, CIE76) was computed for every image. Sharpness was assessed by ISO 12233 slanted‐edge SFR (MTF50) at f/16 and f/22. Linear mixed‐effects models with shade tab as a random effect were fitted; equivalence was tested with two one‐sided tests (TOST) at a prespecified ΔEab margin of 0.6. Results: All macro lenses produced low, clinically acceptable color errors (mean Δ E ab = 1.2; SD = 0.2) with negligible inter‐brand differences, and all macro–macro comparisons met the 0.6 equivalence margin. Zoom lenses showed significantly higher errors (mean = 2.95–3.35; SD = 0.42–0.50) and failed equivalence. Brand differences among macro lenses were non‐significant ( F = 0.92, p = 0.40), whereas macro‐vs‐zoom differences were highly significant ( F = 792.1, p < 0.0001); 81% of pooled zoom images exceeded the ΔEab acceptability threshold of 2.7, versus none of the macro images. MTF50 confirmed superior macro sharpness, with macro–macro differences within ±5% of the Nyquist frequency. Conclusions: Dedicated macro lenses are required for accurate shade photography, with general‐purpose zoom lenses producing clinically unacceptable color errors.

29 September 2026 in European Journal of Dental Education
Verified
Journal Article
Closed access
PDF file
EJEanas I. Jellil
Eanas I. Jellil
MAMustafa N. Abdulghani
Mustafa N. Abdulghani
SNSundus H. Naser
Sundus H. Naser
AMAmer A. Mohammed
Amer A. Mohammed
FAFarah Nabeel AlKhayyat
Farah Nabeel AlKhayyat