13 January 2023 in IEEE Transactions on Robotics
Most impedance-based walking controllers for powered knee–ankle prostheses use a finite state machine with dozens of user-specific parameters that require manual tuning by technical experts. These parameters are only appropriate near the task (e.g., walking speed and incline) at which they were tuned, necessitating many different parameter sets for variable-task walking. In contrast, this article presents a data-driven, phase-based controller for variable-task walking that uses continuously variable impedance control during stance and kinematic control during swing to enable biomimetic locomotion. After generating a data-driven model of variable joint impedance with convex optimization, we implement a novel task-invariant phase variable and real-time estimates of speed and incline to enable autonomous task adaptation. Experiments with above-knee amputee participants ( $N=2$ ) show that our data-driven controller 1) features highly linear phase estimates and accurate task estimates, 2) produces biomimetic kinematic and kinetic trends as task varies, leading to low errors relative to able-bodied references, and 3) produces biomimetic joint work and cadence trends as task varies. We show that the presented controller meets and often exceeds the performance of a benchmark finite state machine controller for our two participants, without requiring manual impedance tuning.
31 October 2023 in IEEE Transactions on Medical Robotics and Bionics
Powered knee-ankle prostheses can offer benefits over conventional passive devices during stair locomotion by providing biomimetic net-positive work and active control of joint angles. However, many modern control approaches for stair ascent and descent are often limited by time-consuming hand-tuning of user/task-specific parameters, predefined trajectories that remove user volition, or heuristic approaches that cannot be applied to both stair ascent and descent. This work presents a phase-based hybrid kinematic and impedance controller (HKIC) that allows for semi-volitional, biomimetic stair ascent and descent at a variety of step heights. We define a unified phase variable for both stair ascent and descent that utilizes lower-limb geometry to adjust to different users and step heights. We extend our prior data-driven impedance model for variable-incline walking, modifying the cost function and constraints to create a continuously-varying impedance parameter model for stair ascent and descent over a continuum of step heights. Experiments with above-knee amputee participants ( $\text{N}=$ 2) validate that our HKIC controller produces biomimetic ascent and descent joint kinematics, kinetics, and work across four step height configurations. We also show improved kinematic performance with our HKIC controller in comparison to a passive microprocessor-controlled device during stair locomotion.
29 September 2023 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Individuals using passive prostheses typically rely heavily on their biological limb to complete sitting and standing tasks, leading to slower completion times and increased rates of osteoarthritis and lower back pain. Powered prostheses can address these challenges, but have control methods that divide sit-stand transitions into discrete phases, limiting user synchronization across the motion and requiring long manual tuning times. This paper extends our preliminary work using a thigh-based phase variable to parameterize optimized data-driven impedance parameter trajectories for sitting, standing, and walking, with only two classification modes. We decouple the stand-to-sit and sit-to-stand equilibrium angles through a knee velocity-dependent scaling term, reducing the model fitting error by approximately half compared to our previous results. We then experimentally validate the controller with three individuals with above-knee amputation performing sitting and standing transitions to/from three different chair heights. We show that our controller implemented on a powered knee-ankle prosthesis produced biomimetic joint mechanics, resulting in significantly reduced sit/stand loading asymmetry and time to complete a 5x sit-to-stand task compared to participants’ passive prostheses. Integration with a previously developed walking controller also allowed sit/walk transitions between different chair heights. The controller’s biomimetic assistance may reduce the overreliance on the biological limb caused by inadequate passive prostheses, helping improve mobility for people with above-knee amputations.
5 February 2025 in IEEE Transactions on Robotics
For powered prosthetic legs to be viable in everyday situations, they require an activity classification system that is not only accurate but also straightforward to understand and use. However, incorporating the numerous activity modes in real-world ambulation often requires high-dimensional feature spaces and restrictions on the leg leading each transition. This article addresses these challenges by delegating sit/stand transitions and variable-incline walking to the mid-level controller, effectively reducing the classification space to four states with easily distinguishable features. We implement simple heuristic rules for both prosthetic-led and intact-led (i.e., ambilateral) transitions, using lower limb kinematic features, ground contact and inclination, and environmental distance from an ultrasonic sensor. Two transfemoral amputee subjects using a powered knee-ankle prosthesis demonstrated an ambilateral transition accuracy of 99.2% under both self-paced and rapid-paced/fatiguing conditions, with a 100% recovery rate due to backup logic or user-cued resets. The incline estimator enabled the prosthesis to continuously adapt between level and inclined surfaces without explicit classification. These results and an outdoor multiterrain demonstration indicate that simple and straightforward transition logic can enable powered prosthetic legs to be used reliably across a broad array of daily activities.
19 December 2024 in IEEE/ASME Transactions on Mechatronics
Accurate impedance control is key for biomimetic mechanical behavior in lower-limb robotic prostheses. However, due to compliance, friction, and inertia in the drivetrain, the commonly used open-loop impedance control strategy can often produce inaccurate results without appropriate compensation. This article presents a controller that accounts for these dynamics to improve the impedance rendering accuracy of a robotic prosthesis research platform, the Open-Source Leg (OSL v2). We first develop a dynamic model of the OSL v2’s drivetrain and show that it accurately predicts the system's joint torque with 97% mean explained variance across a diverse array of experiments. We then present a controller that compensates for the OSL v2’s inherent dynamics using a combination of feedback linearization and actuator-state feedback control. We experimentally validate this controller on the OSL v2 with a rotary dynamometer and in treadmill walking experiments. We show that it can render various constant impedance behaviors with higher stiffness and damping accuracy than a baseline controller. We also show our controller's ability to replicate the variable impedance trajectories of the human ankle joint, suggesting that this control approach could enable robotic prostheses that are biomimetic in their mechanical impedance in addition to their kinematics and kinetics.
1 October 2023 in 2013 IEEE/RSJ International Conference on Intelligent Robots and Systems
Robotic knee-ankle prostheses have often fallen short relative to passive microprocessor prostheses in time-based clinical outcome tests. User ambulation endurance is an alternative clinical outcome metric that may better highlight the benefits of robotic prostheses. However, previous studies were unable to show endurance benefits due to inaccurate high-level classification, discretized mid-level control, and in-sufficiently difficult ambulation tasks. In this case study, we present a phase-based mid-level prosthesis controller which yields biomimetic joint kinematics and kinetics that adjust to suit a continuum of tasks. We enrolled an individual with an above-knee amputation and challenged him to perform repeated, rapid laps of a circuit comprising activities of daily living with both his passive prosthesis and a robotic prosthesis. The participant demonstrated improved endurance with the robotic prosthesis and our mid-level controller compared to his passive prosthesis, completing over twice as many total laps before fatigue and muscle discomfort required him to stop. We also show that time-based outcome metrics fail to capture this endurance improvement, suggesting that alternative metrics related to endurance and fatigue may better highlight the clinical benefits of robotic prostheses.