3 January 2020 in Science Advances
Lithium-sulfur batteries can displace lithium-ion by delivering higher specific energy. Presently, however, the superior energy performance fades rapidly when the sulfur electrode is loaded to the required levels—5 to 10 mg cm−2— due to substantial volume change of lithiation/delithiation and the resultant stresses. Inspired by the classical approaches in particle agglomeration theories, we found an approach that places minimum amounts of a high-modulus binder between neighboring particles, leaving increased space for material expansion and ion diffusion. These expansion-tolerant electrodes with loadings up to 15 mg cm−2 yield high gravimetric (>1200 mA·hour g−1) and areal (19 mA·hour cm−2) capacities. The cells are stable for more than 200 cycles, unprecedented in such thick cathodes, with Coulombic efficiency above 99%.
28 April 2021 in Journal of Materials Chemistry C
Naturally occurring enzymes are highly selective and efficient catalysts but given their intricate and fragile structure, wide application of their extraordinary catalytic potential in industrial and biomedical settings is highly desirable yet challenging. In this work we demonstrate this possibility using a facile, single-step technique for metal–organic framework (MOF) biomimetic mineralisation of three different enzymes of industrial interest; glucose oxidase (GOx), organophosphate degrading enzyme A (OpdA) and α-chymotrypsin. We investigate the thermal stability of the resulting ZIF-8@enzyme composites at temperatures in the industrially relevant range of 50–80 °C with time ranging from minutes to hours. In situ thermal stabilisation analysis was performed at the small angle X-ray scattering (SAXS) beamline to understand the effect of temperature on the ZIF-8@GOx composite. Furthermore, we illustrate the electrochemical operational stability of a ZIF-8@GOx modified electrode at challenging elevated temperatures validating its potent application in electrochemical devices. The resulting optimized and ultra-stable amperometric glucose biosensor demonstrates a clinically relevant wide linear range of 1–10 mM glucose with a detection limit of 0.05 mM. The biosensor demonstrates robust performance and selectivity with insignificant interference effects in the presence of 100 μM uric acid, acetaminophen and ascorbic acid, respectively, and satisfactory operation in up to 20% serum environment.
4 August 2022 in ChemSusChem
Per‐ and polyfluoroalkyl substances (PFAS) are a group of recalcitrant molecules that have been used since the 1940s in a variety of applications. They are now linked to a host of negative health outcomes and are extremely resistant to degradation under environmental conditions. Currently, membrane technologies or adsorbents are used to remediate contaminated water. These techniques are either inefficient at capturing smaller PFAS molecules, have high energy demands, or result in concentrated waste that must be incinerated at high temperatures. This Review focuses on what role metal‐organic frameworks (MOFs) may play in addressing the PFAS problem. Specifically, how the unique properties of MOFs such as their well‐defined pore sizes, ultra‐high internal surface area, and tunable surface chemistry may be a sustainable solution for PFAS contamination.
5 February 2022 in Acta Biomaterialia
11 June 2020 in Advanced Sustainable Systems
27 October 2020 in New Journal of Chemistry
Docetaxel (DTX) is a widely used chemotherapy drug that is associated with numerous side effects and limited bioavailability. Macromolecular conjugates of DTX may improve drug targeting, solubility, reduce off-target toxicity, and overcome mechanisms of multidrug resistance. However, most polymer conjugates of DTX investigated to date make use of biopolymers, which are of fixed structure and are not well suited to optimisation and subsequent reaction to introduce further functionality. Here, we show the preparation of synthetic copolymer conjugates of DTX with drug loading of up to 20% w/w that also has potential for tuning backbone hydrophilicity and the number of reactive sites for conjugation. The intermediates produced are comprehensively characterised, as are the macromolecular conjugates, which are tested in the MCF-7 human breast adenocarcinoma cell line to assess toxicity and anticancer efficacy. The conjugates produced have IC50 values within one order of magnitude of DTX, as expected for slow release of DTX by ester hydrolysis. The results suggest that the system is promising for delivery of DTX and future work may examine conjugates of a wider molecular weight range, optimisation of DTX and PEG conjugation efficiency, and in vivo biodistribution.