Kosuke Iwano

Kosuke Iwano

Auto-generated profile, based on publicly available information

Kosuke Iwano

Center for Gastroenterology Teine Keijinkai Hospital Sapporo Japan

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 September 2023 in Journal of Hepato-Biliary-Pancreatic Sciences
Verified
Journal Article
Closed access
TITatsuya Ishii
Tatsuya Ishii
THTsuyoshi Hayashi
Tsuyoshi Hayashi
HYHajime Yamazaki
Hajime Yamazaki
RNRisa Nakamura
Risa Nakamura
KIKosuke Iwano
Kosuke Iwano
AKAkio Katanuma
Akio Katanuma

22 October 2022 in Digestive Endoscopy
Verified
Journal Article
Closed access
HTHaruka Toyonaga
Haruka Toyonaga
THTsuyoshi Hayashi
Tsuyoshi Hayashi
HYHajime Yamazaki
Hajime Yamazaki
KHKazuki Hama
Kazuki Hama
KIKosuke Iwano
Kosuke Iwano
AKAkio Katanuma
Akio Katanuma

15 November 2022 in Journal of Hepato-Biliary-Pancreatic Sciences
Verified
Journal Article
Closed access
HTHaruka Toyonaga
Haruka Toyonaga
TKToshifumi Kin
Toshifumi Kin
KIKosuke Iwano
Kosuke Iwano
RNRisa Nakamura
Risa Nakamura
TITatsuya Ishii
Tatsuya Ishii
AKAkio Katanuma
Akio Katanuma

4 August 2022 in DEN Open
Verified
Journal Article
Open access
HTHaruka Toyonaga
Haruka Toyonaga
TKToshifumi Kin
Toshifumi Kin
KIKosuke Iwano
Kosuke Iwano
RNRisa Nakamura
Risa Nakamura
TSTakao Shimizu
Takao Shimizu
AKAkio Katanuma
Akio Katanuma
Objectives: Endoscopic ultrasonography is an important examination for periampullary diseases. The duodenum is filled with water to ensure a clear image and distend the duodenal wall without burying the papilla within duodenal folds; however, peristalsis frequently makes it difficult to maintain water within the duodenum. The gel immersion method (intestine is filled with viscosity gel) has recently been attracting attention. We evaluated the usefulness of using this method for endoscopic ultrasonography to detect and delineate the major duodenal papilla.Methods: Fifty‐nine consecutive patients who underwent gel immersion‐endoscopic ultrasonography between February and March 2021 were included retrospectively. The papilla was observed by filling the duodenum with clear viscosity gel. Outcomes were the rate of duodenal distention, delineation rates of the papilla, the time required for delineation, volume of the gel used, and adverse events.Results: Duodenal distention was excellent, good, and poor in 58%, 34%, and 7% of cases, respectively. The delineation rates of the papilla in the axial and longitudinal views were 98% and 66%, respectively. The median time required to delineate the papilla in each view was 3.1 (range, 1.0–1.4) and 7.9 (1.9–28.6) min; the median volume of the gel used was 80 (30–150) ml and 100 (50–200) ml, respectively. No adverse events were noted.Conclusions: Gel immersion‐endoscopic ultrasonography provided sufficient duodenal distention, leading to high rates of detection and delineation of the papilla using a small volume of gel within a short time. This method may be useful for the evaluation of the ampullary region.

19 January 2022 in Digestive Endoscopy
Verified
Journal Article
Open access
PDF file
KIKosuke Iwano
Kosuke Iwano
KKKatsutoshi Kuriyama
Katsutoshi Kuriyama
SYShujiro Yazumi
Shujiro Yazumi
Watch a video of this article.

8 April 2022 in Endoscopy
Verified
Journal Article
Open access
PDF file
KIKosuke Iwano
Kosuke Iwano
HTHaruka Toyonaga
Haruka Toyonaga
TKToshifumi Kin
Toshifumi Kin
TITatsuya Ishii
Tatsuya Ishii
AKAkio Katanuma
Akio Katanuma
Periampullary diverticulum (PAD) is considered a risk factor for difficult biliary cannulation during endoscopic retrograde cholangiopancreatography (ERCP) because it makes the papilla unidentifiable [1]. Applying a traction force near the papilla has been reported to be effective in PAD biliary interventions [2]. We report a successful case of endoscopic hemostasis in post-sphincterotomy bleeding, using the multiloop traction method (M-loop method), in a patient with PAD [3] ([Video 1]). Video 1 Endoscopic hemostasis, achieved using the multiloop traction method for post-sphincterotomy bleeding of the peridiverticular papilla. A 79-year-old man, taking direct oral anticoagulants (DOACs) for atrial fibrillation, presented with symptomatic common bile duct stones. His DOAC medication was temporarily discontinued on the day of the procedure. A successful endoscopic sphincterotomy (ES), with complete stone removal, was achieved. Post-ES bleeding was noted 4 days after the procedure ([Fig. 1]). Achieving endoscopic hemostasis was challenging because the bleeding source was covered with duodenal mucosal folds. The M-loop method was used to locate and expose the bleeding source ([Fig. 2]). A SureClip (Micro-Tech, Nanjing, China), attached to a multiple-loop-thread, was deployed to cover the mucosal fold. Additional clips were hooked onto the free loop and attached to the oral side of the duodenal wall. A traction force was generated to pull the duodenal mucosa covering the papilla upward. The bleeding point was sufficiently exposed ([Fig. 3], [Fig. 4]). A pancreatic stent was placed to avoid post-ERCP pancreatitis. Successful hemostasis was achieved with endoscopic coagulation, using a Coagrasper (Olympus, Tokyo, Japan) ([Fig. 5]). The threads used in the M-loop method were cut after hemostasis. Rebleeding was not observed after restarting DOAC therapy. PAD has been reported to be a risk factor for post-ES bleeding [4]. Hemostasis for post-ES bleeding may be challenging in patients with PAD due to the deviation of the papilla’s position. Traction, using the M-loop method, provides adequate exposure of the papilla, facilitating hemostasis in patients with post-ES bleeding. Endoscopy_UCTN_Code_CPL_1AK_2AI Publication Date: 08 April 2022 (online) © 2022. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/) Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany