1 December 2016 in IEEE Transactions on Industry Applications
The prospective spread of Electric vehicles (EV) and plug-in hybrid electric vehicles arises the need for fast charging rates. High required charging rates lead to high power demands, which may not be supported by the grid. In this paper, an optimal power flow technique of a PV-battery powered fast EV charging station is presented to continuously minimize the operation cost. The objective is to help the penetration of PV-battery systems into the grid and to support the growing need of fast EV charging. An optimization problem is formulated along with the required constraints and the operating cost function is chosen as a combination of electricity grid prices and the battery degradation cost. In the first stage of the proposed optimization procedure, an offline particle swarm optimization (PSO) is performed as a prediction layer. In the second stage, dynamic programming (DP) is performed as an online reactive management layer. Forecasted system data is utilized in both stages to find the optimal power management solution. In the reactive management layer, the outputs of the PSO are used to limit the available state trajectories used in the DP and, accordingly, improve the system computation time and efficiency. Online error compensation is implemented into the DP and fed back to the prediction layer for necessary prediction adjustments. Simulation and a 1 kW prototype experimental results are successfully implemented to validate the system effectiveness and to demonstrate the benefits of using a hybrid grid tied system of PV-battery for fast EVs charging stations.
12 September 2017 in IEEE Transactions on Industry Applications
This paper proposes a fault diagnosis and identification method for non-isolated dc-dc converters. The method can detect the fault, identify the faulty switch, and the switch fault type in less than one switching cycle. The main idea is to apply the derivative of the inductor current, based on the modulation of the particular dc-dc converter, to provide a predictive current emulator model. The measured inductor current and its corresponding predicted current are used to diagnose the switch fault. The method, implemented on a DSP, is robust to common converter asymmetry such as load variations, input disturbances, etc. The proposed fault diagnosis method has been analyzed, tested, and validated for a boost converter.
9 July 2018 in IEEE Transactions on Industrial Electronics
In this paper, a unified controller for switched-reluctance motors is proposed for wide speed operations. In the proposed controller, overlapping regions between the phases are controlled such that direct instantaneous torque control (DITC) and current control (CC) can be implemented simultaneously on different phases. This simplifies the torque sharing during commutation and minimizes torque ripple due to imperfect current tracking and mutual torque. A demagnetization curve concept to demagnetize the phase currents at an optimum angle is introduced to ensure high torque per ampere and single pulse mode operation. This results in extending low ripple operation to medium speed ranges. The seamless combination of DITC, CC and the demagnetization curves lead to torque ripple minimization, automatic excitation angle control and smooth operation over wide speed range. The effectiveness of the proposed unified controller is verified through simulation and experimental studies.
1 August 2012 in IEEE Transactions on Industry Applications
This paper proposes a smooth transition control strategy for voltage-source inverters between standalone (SA) and grid-connected (GC) modes of operation. In the GC mode, the amount of power exchanged with the utility grid is controlled by regulating the phase currents. In the SA mode, the load voltage is regulated by the inverter with its phase dictated by the inverter control. The transition between SA and GC operations that will ensure continuous power delivery to the load requires continuation in the phase of the system voltage. The proportional-integral, trapezoidal, sinusoidal, and staircase frequency variation techniques have been analyzed to find the best approach for minimizing the total harmonic distortion (THD). A smooth frequency variation technique has been developed, which provides lower THD on the voltage waveforms compared with the other techniques. The new algorithm has been implemented on a 5-kW single-phase utility interactive inverter having the SA operation capability. The simulation and experimental results show that the proposed technique provides seamless transition between the inverter modes of operation with minimal distortion at the inverter output voltage.
1 December 2016 in IEEE Transactions on Industry Applications
Droop control is a widely used technique for load sharing in DC microgrids. However, it has an inherent limitation that leads to voltage deviations at the DC bus. More importantly, its current sharing performance is degraded due to voltage drops across transmission line impedances. Depending on the amount of these voltage drops over the DC bus, droop control leads to different current sharing errors and DC bus voltage degradations. Therefore, MG topology and loading conditions (LCs) have a considerable effect on current sharing accuracy and voltage regulation. In this paper, an optimization procedure accounting all necessary information is introduced to find optimal droop parameters for the droop mechanism. First, a proper optimization problem is defined with required constrains and a cost function formulated as a summation of the current sharing errors and the voltage degradations occurring at various LCs. Then, an optimization tool named as particle swarm is implemented to converge a satisfactory solution. During the computations, the cost impact of the current sharing error at each LC is weighted based on the probability of occurrence of that LCs, which is obtained from the stochastic load model for the considered MG. The effectiveness of the optimal droop parameters is verified through a simulation performed on MATLAB/Simulink and a DC MG test bench is prototyped for experimental validation.
14 July 2021 in IEEE Transactions on Industrial Electronics
Multiphysics analysis and experimental validation of acoustic noise reduction in a high pole count, high power, switched reluctance machine (SRM), through skewing are explored in detail in this work. An iterative optimization strategy covering electromagnetic, structural, and thermal domains is proposed to investigate the effect of different skewing methods and angles on a 24-stator slot/16-rotor pole (24/16) SRM rated at 100 kW. The contributions of this work are twofold. First, electromagnetic impact, considering average torque, torque ripple, radial and tangential air gap forces, of symmetric and asymmetric skewing on stator and rotor is studied in this work. Second, the impact of skewing methods on acoustic noise and vibration performance is studied and presented in detail. The study reveals that skewing both the stator and rotor by the same amount has superior electromagnetic performance over other types of skewing. Multiphysics simulations conducted, predict a 10.5 dBA reduction in the acoustic noise, compared to a baseline design with no skew, for an optimized rotor-stator skewing angle of 13.75°. Finally, 100 kW prototypes of the baseline and the optimized skewed SRM were constructed and subjected to wide speed range testing. Simulation and test results closely follow each other and validate the effectiveness of the proposed skew design in mitigating acoustic noise and vibration in high pole count SRMs.