Emma L. Talbot

Emma L. Talbot

Auto-generated profile, based on publicly available information

Emma L. Talbot

Lightcast Discovery Ltd

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 June 2014 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
ETEmma L. Talbot
Emma L. Talbot
LYLisong Yang
Lisong Yang
ABArganthaël Berson
Arganthaël Berson
CBColin D. Bain
Colin D. Bain

17 May 2017 in Nature Communications
Verified
Journal Article
Open access
PDF file
ETEmma L. Talbot
Emma L. Talbot
JKJurij Kotar
Jurij Kotar
LPLucia Parolini
Lucia Parolini
LMLorenzo Di Michele
Lorenzo Di Michele
PCPietro Cicuta
Pietro Cicuta
A number of colloidal systems, including polymers, proteins, micelles and hard spheres, have been studied in thermal gradients to observe and characterize their driven motion. Here we show experimentally the thermophoretic behaviour of unilamellar lipid vesicles, finding that mobility depends on the mean local temperature of the suspension and on the structure of the exposed polar lipid head groups. By tuning the temperature, vesicles can be directed towards hot or cold, forming a highly concentrated region. Binary mixtures of vesicles composed of different lipids can be segregated using thermophoresis, according to their head group. Our results demonstrate that thermophoresis enables robust and chemically specific directed motion of liposomes, which can be exploited in driven processes.

4 February 2015 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
ETEmma L. Talbot
Emma L. Talbot
HYHuai N. Yow
Huai N. Yow
LYLisong Yang
Lisong Yang
ABArganthaël Berson
Arganthaël Berson
SBSimon R. Biggs
Simon R. Biggs
CBColin D. Bain
Colin D. Bain

17 January 2017 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Closed access
PDF file
ETEmma L. Talbot
Emma L. Talbot
LPLucia Parolini
Lucia Parolini
JKJurij Kotar
Jurij Kotar
LMLorenzo Di Michele
Lorenzo Di Michele
PCPietro Cicuta
Pietro Cicuta
Significance: Giant phospholipid and sterol vesicles can separate into coexisting phase domains, observable by fluorescence microscopy. The morphology and motility of these domains provides a simplified model for processes in the plasma membrane of cells. Previous studies maintained a uniform temperature across a vesicle and showed that the morphology of the domains depends on the membrane composition and temperature. We observed the nonequilibrium behavior of domains due to a temperature gradient, revealing domain migration toward higher temperatures. This motion provides a method for controlling the localization of each phase. Species that associate with the sterol-rich regions, such as DNA constructs, can also be actively transported on the vesicle surface, allowing control over the distribution and confinement of that species via vesicle morphology.

5 November 2020 in Nucleic Acids Research
Verified
Journal Article
Open access
PDF file
TPTim J Puchtler
Tim J Puchtler
KJKerr Johnson
Kerr Johnson
RPRebecca N Palmer
Rebecca N Palmer
ETEmma L Talbot
Emma L Talbot
LILindsey A Ibbotson
Lindsey A Ibbotson
CFCameron A Frayling
Cameron A Frayling
Despite remarkable progress in DNA sequencing technologies there remains a trade-off between short-read platforms, having limited ability to sequence homopolymers, repeated motifs or long-range structural variation, and long-read platforms, which tend to have lower accuracy and/or throughput. Moreover, current methods do not allow direct readout of epigenetic modifications from a single read. With the aim of addressing these limitations, we have developed an optical electrowetting sequencing platform that uses step-wise nucleotide triphosphate (dNTP) release, capture and detection in microdroplets from single DNA molecules. Each microdroplet serves as a reaction vessel that identifies an individual dNTP based on a robust fluorescence signal, with the detection chemistry extended to enable detection of 5-methylcytosine. Our platform uses small reagent volumes and inexpensive equipment, paving the way to cost-effective single-molecule DNA sequencing, capable of handling widely varying GC-bias, and demonstrating direct detection of epigenetic modifications.

19 March 2024 in bioRxiv
Verified
Preprint
Open access
PDF file
LWLawrence G. Welch
Lawrence G. Welch
JEJasper Estranero
Jasper Estranero
PTPanagiotis Tourlomousis
Panagiotis Tourlomousis
RWRobert C. R. Wootton
Robert C. R. Wootton
VRValentin Radu
Valentin Radu
ETEmma L. Talbot
Emma L. Talbot
Recently, there has been an increasing emphasis on single cell profiling for high-throughput screening workflows in drug discovery and life sciences research. However, the biology underpinning these screens is often complex and is insufficiently addressed by singleplex assay screens. Traditional single cell screening technologies have created powerful sets of ‘omic data that allow users to bioinformatically infer biological function, but have as of yet not empowered direct functional analysis at the level of each individual cell. Consequently, screening campaigns often require multiple secondary screens leading to laborious, time-consuming and expensive workflows in which attrition points may not be queried until late in the process. We describe a platform that harnesses droplet microfluidics and optical electrowetting-on-dielectric (oEWOD) to perform highly-controlled sequential and multiplexed single cell assays in massively parallelised workflows to enable complex cell profiling during screening. Soluble reagents or objects, such as cells or assay beads, are encapsulated into droplets of media in fluorous oil and are actively filtered based on size and optical features ensuring only desirable droplets (e.g. single cell droplets) are retained for analysis, thereby overcoming the Poisson probability distribution. Droplets are stored in an array on a temperature-controlled chip and the history of individual droplets is logged from the point of filter until completion of the workflow. On chip, droplets are subject to an automated and flexible suite of operations including the merging of sample droplets and the fluorescent acquisition of assay readouts to enable complex sequential assay workflows. To demonstrate the broad utility of the platform, we present examples of single-cell functional workflows for various applications such as antibody discovery, infectious disease, and cell and gene therapy.