Purpose: Current FDA-approved imaging modalities are inadequate for localizing prostate cancer biochemical recurrence (BCR). 18F-DCFPyL is a highly selective, small-molecule prostate-specific membrane antigen–targeted PET radiotracer. CONDOR was a prospective study designed to determine the performance of 18F-DCFPyL-PET/CT in patients with BCR and uninformative standard imaging. Experimental Design: Men with rising PSA ≥0.2 ng/mL after prostatectomy or ≥2 ng/mL above nadir after radiotherapy were eligible. The primary endpoint was correct localization rate (CLR), defined as positive predictive value with an additional requirement of anatomic lesion colocalization between 18F-DCFPyL-PET/CT and a composite standard of truth (SOT). The SOT consisted of, in descending priority (i) histopathology, (ii) subsequent correlative imaging findings, or (iii) post-radiation PSA response. The trial was considered a success if the lower bound of the 95% confidence interval (CI) for CLR exceeded 20% for two of three 18F-DCFPyL-PET/CT readers. Secondary endpoints included change in intended management and safety. Results: A total of 208 men with a median baseline PSA of 0.8 ng/mL (range: 0.2–98.4 ng/mL) underwent 18F-DCFPyL-PET/CT. The CLR was 84.8%–87.0% (lower bound of 95% CI: 77.8–80.4). A total of 63.9% of evaluable patients had a change in intended management after 18F-DCFPyL-PET/CT. The disease detection rate was 59% to 66% (at least one lesion detected per patient by 18F-DCFPyL-PET/CT by central readers). Conclusions: Performance of 18F-DCFPyL-PET/CT achieved the study’s primary endpoint, demonstrating disease localization in the setting of negative standard imaging and providing clinically meaningful and actionable information. These data further support the utility of 18F-DCFPyL-PET/CT to localize disease in men with recurrent prostate cancer. See related commentary by True and Chen, p. 3512
PURPOSE: NRG-RTOG0617 demonstrated a detrimental effect of uniform high-dose radiation in stage III non–small cell lung cancer. NRG-RTOG1106/ECOG-ACRIN6697 (ClinicalTrials.gov identifier: NCT01507428 ), a randomized phase II trial, studied whether midtreatment 18 F-fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) can guide individualized/adaptive dose-intensified radiotherapy (RT) to improve and predict outcomes in patients with this disease. MATERIALS AND METHODS: Patients fit for concurrent chemoradiation were randomly assigned (1:2) to standard (60 Gy/30 fractions) or FDG-PET–guided adaptive treatment, stratified by substage, primary tumor size, and histology. All patients had midtreatment FDG-PET/CT; adaptive arm patients had an individualized, intensified boost RT dose to residual metabolically active areas. The primary therapeutic end point was 2-year centrally reviewed freedom from local-regional progression (FFLP), defined as no progression in or near the planning target volume and/or regional nodes. FFLP was analyzed on a modified intent-to-treat population at a one-sided Z -test significance level of 0.15. The primary imaging end point was centrally reviewed change in SUV peak from baseline to midtreatment; its association with FFLP was assessed using the two-sided Wald test on the basis of Cox regression. RESULTS: Of 138 patients enrolled, 127 were eligible. Adaptive-arm patients received a mean 71 Gy in 30 fractions, with mean lung dose 17.9 Gy. There was no significant difference in centrally reviewed 2-year FFLP (59.5% and 54.6% in standard and adaptive arms; P = .66). There were no significant differences in protocol-specified grade 3 toxicities, survival, or progression-free survival ( P > .4). Median SUV peak and metabolic tumor volume (MTV) in the adaptive arm decreased 49% and 54%, from pre-RT to mid-RT PET. However, ΔSUV peak and ΔMTV were not associated with FFLP (hazard ratios, 0.997; P = .395 and .461). CONCLUSION: Midtreatment PET-adapted RT dose escalation as given in this study was safe and feasible but did not improve efficacy outcomes.
Estrogen receptor (ER) testing of breast cancer imperfectly predicts response to endocrine therapy (ET). We hypothesize that a brief estradiol challenge will increase tumor progesterone receptor (PgR) levels only in tumors with functional ER. In this prospective, phase 2, single-center, single-arm trial (NCT02455453), we report the association of response to ET with change in tumor uptake of the progestin analog, 21-[18F]fluorofuranylnorprogesterone (FFNP), before and after a one-day estradiol challenge. In 43 postmenopausal women with advanced ER+ breast cancer, we show a post-challenge increase in tumor FFNP uptake only in 28 subjects with clinical benefit from ET (responders), but not in 15 without clinical benefit (nonresponders) (p < 0.0001), indicating 100% sensitivity and specificity. We further show significantly longer survival (p < 0.0001) in the responding subjects. Our results demonstrate that change in tumor FFNP uptake after estradiol challenge is highly predictive of response to ET in women with ER+ breast cancer.
Purpose: Chemoradiotherapy for locally advanced cervical cancer fails in over a third of patients. Biomarkers with therapeutic implications are therefore needed. We investigated the relationship between an established prognostic marker, maximum standardized uptake value (SUVmax) on 18F-fluorodeoxyglucose positron emission tomography, and the inflammatory and immune state of cervical cancers. Experimental Design: An SUVmax most prognostic for freedom from progression (FFP) was identified and compared with known prognostic clinical variables in a cohort of 318 patients treated with definitive radiation with prospectively collected clinical data. Gene set enrichment analysis (GSEA) and CIBERSORT of whole-transcriptome data from 68 patients were used to identify biological pathways and immune cell subpopulations associated with high SUVmax. IHC using a tissue microarray (TMA, N = 82) was used to validate the CIBERSORT findings. The impact of macrophages on cervical cancer glucose metabolism was investigated in coculture experiments. Results: SUVmax <11.4 was most prognostic for FFP (P = 0.001). The GSEA showed that high SUVmax is associated with increased gene expression of inflammatory pathways, including JAK/STAT3 signaling. CIBERSORT and CD68 staining of the TMA showed high SUVmax tumors are characterized by a monocyte-predominant immune infiltrate. Coculture of cervical cancer cells with macrophages or macrophage-conditioned media altered glucose uptake, and IL6 and JAK/STAT3 signaling contribute to this effect. Conclusions: SUVmax is a prognostic marker in cervical cancer that is associated with activation of inflammatory pathways and tumor infiltration of myeloid-derived immune cells, particularly macrophages. Macrophages contribute to changes in cervical cancer glucose metabolism. See related commentary by Williamson et al., p. 4136
25 March 2024 in IEEE Transactions on Radiation and Plasma Medical Sciences
There is an important need for methods to process myocardial perfusion imaging (MPI) single-photon emission computed tomography (SPECT) images acquired at lower-radiation dose and/or acquisition time such that the processed images improve observer performance on the clinical task of detecting perfusion defects compared to low-dose images. To address this need, we build upon concepts from model-observer theory and our understanding of the human visual system to propose a detection task-specific deep-learning-based approach for denoising MPI SPECT images (DEMIST). The approach, while performing denoising, is designed to preserve features that influence observer performance on detection tasks. We objectively evaluated DEMIST on the task of detecting perfusion defects using a retrospective study with anonymized clinical data in patients who underwent MPI studies across two scanners ( $N\,\,=$ 338). The evaluation was performed at low-dose levels of 6.25%, 12.5%, and 25% and using an anthropomorphic channelized Hotelling observer. Performance was quantified using area under the receiver operating characteristics curve (AUC). Images denoised with DEMIST yielded significantly higher AUC compared to corresponding low-dose images and images denoised with a commonly used task-agnostic deep learning-based denoising method. Similar results were observed with stratified analysis based on patient sex and defect type. Additionally, DEMIST improved visual fidelity of the low-dose images as quantified using root mean squared error and structural similarity index metric. A mathematical analysis revealed that DEMIST preserved features that assist in detection tasks while improving the noise properties, resulting in improved observer performance. The results provide strong evidence for further clinical evaluation of DEMIST to denoise low-count images in MPI SPECT.
25 November 2024 in IEEE Transactions on Medical Imaging
Attenuation compensation (AC), while being beneficial for visual-interpretation tasks in myocardial perfusion imaging (MPI) by single-photon emission computed tomography (SPECT), typically requires the availability of a separate X-ray CT component, leading to additional radiation dose, higher costs, and potentially inaccurate diagnosis in case of misalignment between SPECT and CT images. To address these issues, we developed a method for cardiac SPECT AC using deep learning and emission scatter-window photons without a separate transmission scan (CTLESS). In this method, an estimated attenuation map reconstructed from scatter-energy window projections is segmented into different regions using a multi-channel input multi-decoder network trained on CT scans. Pre-defined attenuation coefficients are assigned to these regions, yielding the attenuation map used for AC. We objectively evaluated this method in a retrospective study with anonymized clinical SPECT/CT stress MPI images on the clinical task of detecting perfusion defects with an anthropomorphic model observer. CTLESS yielded statistically non-inferior performance compared to a CT-based AC (CTAC) method and significantly outperformed a non-AC (NAC) method on this clinical task. Similar results were observed in stratified analyses with different sexes, defect extents, and defect severities. The method was observed to generalize across two SPECT scanners, each with a different camera. In addition, CTLESS yielded similar performance as CTAC and outperformed NAC method on the fidelity-based figures of merit, namely, root mean squared error (RMSE) and structural similarity index measure (SSIM). Moreover, as we reduced the training dataset size, CTLESS yielded relatively stable AUC values and generally outperformed another DL-based AC method that directly estimated the attenuation coefficient within each voxel. These results demonstrate the capability of the CTLESS method for transmission-less AC in SPECT and motivate further clinical evaluation.