Soumyadipta Acharya

Soumyadipta Acharya

Auto-generated profile, based on publicly available information

Soumyadipta Acharya

Department of Biomedical Engineering, Center for Bioengineering Innovation & Design, Johns Hopkins University, Baltimore, USA

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 October 2007 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
ACAniruddha Chatterjee
Aniruddha Chatterjee
VAVikram Aggarwal
Vikram Aggarwal
ARAnder Ramos-Murguialday
Ander Ramos-Murguialday
SASoumyadipta Acharya
Soumyadipta Acharya
NTNitish Thakor
Nitish Thakor
It has been suggested that Brain-Computer Interfaces (BCI) may one day be suitable for controlling a neuroprosthesis. For closed-loop operation of BCI, a tactile feedback channel that is compatible with neuroprosthetic applications is desired. Operation of an EEG-based BCI using only vibrotactile feedback, a commonly used method to convey haptic senses of contact and pressure, is demonstrated with a high level of accuracy.

20 May 2010 in Journal of Neural Engineering
Verified
Journal Article
Closed access
SASoumyadipta Acharya
Soumyadipta Acharya
MFMatthew S Fifer
Matthew S Fifer
HBHeather L Benz
Heather L Benz
NCNathan E Crone
Nathan E Crone
NTNitish Thakor
Nitish Thakor
Four human subjects undergoing subdural electrocorticography for epilepsy surgery engaged in a range of finger and hand movements. We observed that the amplitudes of the low-pass filtered electrocorticogram (ECoG), also known as the local motor potential (LMP), over specific peri-Rolandic electrodes were correlated (p < 0.001) with the position of individual fingers as the subjects engaged in slow and deliberate grasping motions. A generalized linear model (GLM) of the LMP amplitudes from those electrodes yielded predictions for positions of the fingers that had a strong congruence with the actual finger positions (correlation coefficient, r; median = 0.51, maximum = 0.91), during displacements of up to 10 cm at the fingertips. For all the subjects, decoding filters trained on data from any given session were remarkably robust in their prediction performance across multiple sessions and days, and were invariant with respect to changes in wrist angle, elbow flexion and hand placement across these sessions (median r = 0.52, maximum r = 0.86). Furthermore, a reasonable prediction accuracy for grasp aperture was achievable with as few as three electrodes in all subjects (median r = 0.49; maximum r = 0.90). These results provide further evidence for the feasibility of robust and practical ECoG-based control of finger movements in upper extremity prosthetics.

1 July 2021 in Scientific Reports
Verified
Journal Article
Open access
PDF file
AGAutumn Goodwin
Autumn Goodwin
SPSanket Padmanabhan
Sanket Padmanabhan
SHSanchit Hira
Sanchit Hira
MGMargaret Glancey
Margaret Glancey
MSMonet Slinowsky
Monet Slinowsky
SASoumyadipta Acharya
Soumyadipta Acharya
With over 3500 mosquito species described, accurate species identification of the few implicated in disease transmission is critical to mosquito borne disease mitigation. Yet this task is hindered by limited global taxonomic expertise and specimen damage consistent across common capture methods. Convolutional neural networks (CNNs) are promising with limited sets of species, but image database requirements restrict practical implementation. Using an image database of 2696 specimens from 67 mosquito species, we address the practical open-set problem with a detection algorithm for novel species. Closed-set classification of 16 known species achieved 97.04 ± 0.87% accuracy independently, and 89.07 ± 5.58% when cascaded with novelty detection. Closed-set classification of 39 species produces a macro F1-score of 86.07 ± 1.81%. This demonstrates an accurate, scalable, and practical computer vision solution to identify wild-caught mosquitoes for implementation in biosurveillance and targeted vector control programs, without the need for extensive image database development for each new target region.

20 November 2019 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
SASoumyadipta Acharya
Soumyadipta Acharya
DSDhivya Swaminathan
Dhivya Swaminathan
SDSreetama Das
Sreetama Das
KKKrity Kansara
Krity Kansara
SCSushovan Chakraborty
Sushovan Chakraborty
KAKiran Rangaswamy Aatre
Kiran Rangaswamy Aatre
Objective We describe a novel machine-learning based method to estimate total Hemoglobin (Hb) using photoplethysmograms (PPGs) acquired non-invasively. Methods: In a study conducted in Karnataka, India, 1583 women (pregnant and non-pregnant) of childbearing age, with Hb values ranging between 1.6 to 14.8 g/dL, had their Hb values estimated using intravenous blood samples and concurrently by a finger sensor custom designed and prototyped for this study. The finger sensor collected PPG signals at four wavelengths: 590nm, 660nm, 810nm, and 940nm. A novel feature vector was derived from these PPG. A machine learning model comprising of a two-layer stack of regressors including Least Absolute Shrinkage and Selection Operator (LASSO), Ridge, Elastic Net, Adaptive (Ada) Boost and Support Vector Regressors (SVR) was designed and tested. Results: We report a statistically significant correlation coefficient (CC) of 0.81 (p<0.01) between the Hb value estimated by the proposed methodology and gold standard values of Hb, with a Root Mean Squared Error (RMSE) of 1.353 × 0.042 g/dL. The performance of the stacked regressor model was significantly better than the performance of individual regressors (low RMSE error, and better CC; p<0.05). Post-hoc analysis showed that including pregnant women in the training data set significantly improved the performance of the algorithm. Conclusion: This study demonstrates the feasibility of a machine learning based non-invasive hemoglobin measurement system, especially for maternal anemia detection. Significance: By developing and demonstrating a machine learning approach on a vast data set, we have demonstrated that such an approach could become the basis for a public health screening tool to detect and treat maternal anemia and could supplement global health intervention strategie

1 May 2021 in International Journal of Medical Informatics
Verified
Journal Article
Closed access
NVNeha Verma
Neha Verma
BMBurke Mamlin
Burke Mamlin
JFJan Flowers
Jan Flowers
SASoumyadipta Acharya
Soumyadipta Acharya
ALAlain Labrique
Alain Labrique
TCTheresa Cullen
Theresa Cullen

12 February 2008 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
SASoumyadipta Acharya
Soumyadipta Acharya
FTFrancesco Tenore
Francesco Tenore
VAVikram Aggarwal
Vikram Aggarwal
RERalph Etienne-Cummings
Ralph Etienne-Cummings
MSMarc H. Schieber
Marc H. Schieber
NTNitish Thakor
Nitish Thakor
Individuated finger and wrist movements can be decoded using random subpopulations of neurons that are widely distributed in the primary motor (M1) hand area. This work investigates 1) whether it is possible to decode dexterous finger movements using spatially-constrained volumes of neurons as typically recorded from a microelectrode array; and 2) whether decoding accuracy differs due to the configuration or location of the array within the M1 hand area. Single-unit activities were sequentially recorded from task-related neurons in two rhesus monkeys as they performed individuated movements of the fingers and the wrist. Simultaneous neuronal ensembles were simulated by constraining these activities to the recording field dimensions of conventional microelectrode array architectures. Artificial neural network (ANN) based filters were able to decode individuated finger movements with greater than 90% accuracy for the majority of movement types, using as few as 20 neurons from these ensemble activities. Furthermore, for the large majority of cases there were no significant differences (p < 0.01) in decoding accuracy as a function of the location of the recording volume. The results suggest that a brain-machine interface (BMI) for dexterous control of individuated fingers and the wrist can be implemented using microelectrode arrays placed broadly in the M1 hand area.