The current study presents the hybrid Taguchi-Fuzzy technique to predict the heat transfer coefficient in pool boiling of Copper surfaces with dissimilar coating layer of ZrO2 in the boiling experimental system with saturated water as boiling fluid. A hybrid Taguchi-Fuzzy technique was developed considering the coating thickness, voltage, concentration, and surface roughness as input variables and current, contact angle, wall superheat, heat transfer coefficient as output variables. The commendable correctness is found with the forecast optimal model findings with the experimental investigation in each test case. It is found that the highest performance with the Multi performance characteristics index value is 0.75 for the A4B4C4Dll case, which matched with the experimental result of S4 sample.