Xue-Si Wang

Xue-Si Wang

Auto-generated profile, based on publicly available information

Xue-Si Wang

Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University , No. 2, Anzhen Road, Chaoyang District, Beijing 100029

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2023 in EP Europace
Verified
Journal Article
Open access
PDF file
XLXinmeng Liu
Xinmeng Liu
RLRong Lin
Rong Lin
XPXiaodong Peng
Xiaodong Peng
XWXuesi Wang
Xuesi Wang
YLYukun Li
Yukun Li
NLNian Liu
Nian Liu
Objective: This study aimed to evaluate the feasibility of real-time visualization and mapping of the right phrenic nerve (RPN) by using intracardiac echocardiography (ICE) during atrial fibrillation (AF) ablation.Background: RPN injury is a complication associated with the ablation of AF. Multiple approaches are currently being used to prevent and detect RPN injuries. However, none of these approaches can directly visualize the RPN in real-time during the ablation procedure.Methods and results: The RPN was detected using ICE. The RPN and its adjacent structures were analysed. The relationship between the RPN’s distance from the superior vena cava (SVC) and its pacing capture threshold was quantified. The safety of SVC isolation guided by the ICE-visualized RPN was evaluated. Thirty-eight people were enrolled in this study. The RPN was visualized by ICE in 92% of patients. It ran through the space between the SVC and the mediastinal pleura and had a ‘straw’-like appearance upon ICE imaging. The course of the RPN was close to the SVC (minimum 1.0 ± 0.4 mm) and the right superior pulmonary vein (minimum 14.1 ± 7.3 mm). There was a positive linear correlation between the RPN’s capture threshold and its distance from the SVC (Spearman’s correlation coefficient = 0.728, < 0.001). SVC isolation was guided by the RPN; none of the patients developed an RPN injury.Conclusions: RPN can be visualized by ICE in most patients, thus providing a novel approach for the real-time detection of RPN during AF ablation.

28 March 2025 in EP Europace
Verified
Journal Article
Open access
XWXue-Si Wang
Xue-Si Wang
ZWZe-Yang Wu
Ze-Yang Wu
QWQi Wu
Qi Wu
DLDeyong Long
Deyong Long
CSCai-Hua Sang
Cai-Hua Sang
RTRi-Bo Tang
Ri-Bo Tang
Aims: Steam pops present a significant concern during radiofrequency (RF) ablation of atrial fibrillation (AF). It is crucial to analyse the incidence and ablation characteristics associated with steam pops. This study aims to investigate the occurrence and potential predictors of steam pops. Methods and results: This study included 3263 patients with AF who underwent RF ablation. Patients with paroxysmal AF received bilateral circumferential pulmonary vein (PV) ablation, while those with persistent AF underwent additional linear ablation. The ablation parameters at the sites of steam pops were compared to those at adjacent anatomical locations. A total of 81 steam pops (2.5%) with one pericardial tamponade were recorded. Steam pops were observed at liner ablation sites: 6 (0.4%) at the mitral isthmus, 16 (0.9%) at the tricuspid isthmus (CTI), and 7 (0.5%) along the roofline. The most common sites of steam pops were the anterior edge of the left superior PV and the inferior vena cava side of the CTI. The impedance drop was significantly higher (18.2 ± 9.5 Ω vs. 13.5 ± 4.8 Ω, P < 0.001) at steam pop sites. The optimal cut-off points of impedance drop for predicting steam pops were > 9.5 Ω within the first 3 s, > 10.5 Ω within the first 5 s, > 13.5 Ω within the first 10 s, and > 18.5 Ω in the whole ablation, respectively. Conclusion: The incidence of steam pops during ablation of AF is infrequent. Impedance drop is the only ablation parameter that could predict the occurrence of steam pops.