30 September 2022 in IEEE Transactions on Instrumentation and Measurement
Soil moisture is closely related to the occurrence frequency and the time of landslides disasters, precisely in situ measurement for soil moisture becomes quite critical. The electrodes of conventional dielectric sensor for soil moisture are fragile, large, and unsuitable for integration. Interdigital (IDT) fringing-field capacitive sensors based on printed circuit board (PCB) technology can be used for noncontact measurement and small-scale packaging. In this article, to optimize the sensitivity and penetration depth of the IDT capacitive sensor with a fixed electrode contour area, the influences of IDT fingers shape and size on the sensitivity and penetration depth are discussed in a wide range by using equivalent capacitance theory. Then, the special working cases are intuitively and accurately analyzed by using the finite element analysis (FEA) method. The results show that the sensor with more electrode fingers and smaller finger gap has high sensitivity, yet has a thinner penetration depth, and it requires a tradeoff between sensitivity and penetration depth in practical applications. In addition, the performance of regular and circular IDT sensors with the same specifications is basically identical, and the circular IDT sensor has a slightly better accuracy. Finally, the proposed IDT sensors with different electrode specifications as well as the associated signal conditioning circuit are fabricated and calibrated to verify the theoretical and simulation results. The performance of the designed sensor was compared with other commercial sensors based on the thermogravimetric method. The experimental results meet the expected requirements well, with a repeatability correlation coefficient of $R^{2} \,\,=0.992$ and a mean square error of 0.01089.
23 September 2020 in Journal of Power Electronics
3 January 2024 in IEEE Sensors Journal
Landslide mechanisms research relies significantly on groundwater flow velocity and direction, and typical thermal flow velocity and direction sensors can scarcely achieve the measurement precision needed. Through numerical simulation analysis, the researchers uncover the mechanism underlying the flow velocity solution error caused by the variation of groundwater physical parameters in the existing thermal sensors. Additionally, The thermal conductivity and dynamic viscosity as the critical parameters are pinpointed from the groundwater physical parameters that contribute to the solution error. To improve the accuracy of the flow velocity solution, the existing simplified model is optimized by employing the current values of thermal conductivity and dynamic viscosity of groundwater, which are obtained in real time by integrating the in-situ measurement functions of thermal conductivity and dynamic viscosity. A sensor prototype and an experimental system based on the improved model are constructed for experimental validation. The experimental results demonstrate a significant improvement in the accuracy of the flow velocity solution complying with correction applying this method as compared to the accuracy of the flow velocity solution when thermal conductivity and dynamic viscosity are taken into account as standard constant values. The sensor’s benefits of compactness, cheap production costs, straightforward hardware implementation, and ease of utilization make it preferred for deployment in deep-hole and small-bore groundwater monitoring applications. The sensor, featuring a wide range of potential applications in the field of in-situ precision monitoring of microfluidic flow velocity and flow direction in landslide groundwater, rivers, and lakes, is portable.
1 October 2021 in AIP Advances
Magnetic resonant wireless power transfer (MR-WPT) has several advantages over conventional wired underground power supply methods. However, MR-WPT inevitably encounters metal conductors, which reduce the system efficiency through the eddy loss induced in the conductor by high-frequency electromagnetic waves. In this paper, the effect of resonant frequency variations caused by metal tube interference with the aim of maximizing the system efficiency is studied. According to the variation in the resonant frequency, the system efficiency is analytically derived by an equivalent circuit model. Electromagnetic simulations are carried out to further analyze the metal tube interference on the system. The results demonstrate the existence of an optimal resonant frequency that maximizes the system efficiency. Aluminum tube interference produces a lower optimal resonant frequency and higher efficiency than a 304 stainless-steel tube. When the metal tube is slotted, the optimal slot width and number of slots enhance the maximum efficiency and reduce the optimal resonant frequency and frequency drift. With slot widths of 2 and 8 mm, the system efficiency reaches ∼67% at 40.1 kHz and 55% at 48 kHz, respectively. Finally, different types of slotted tubes are fabricated, and the theoretical results are experimentally verified.
11 September 2024 in IEEE Access
Supplying power for multi-load devices via magnetic resonance wireless power transfer (MR-WPT) has attracted extensive attention, but it also presents more challenging analysis for the system configuration. This study provides an optimization analysis of coil position considering the cross-coupling effect, thereby improving the performance of a dual-receiver MR-WPT system with dynamic transmitting coil (Tx-coil) position. First, the expression of the overall power transfer efficiency (PTE) and the optimal load are derived using equivalent circuit model (ECM), and a comparative discussion of the system characteristics with and without cross-coupling is carried out. It shows that the PTE reaches the peak at the resonant frequency of each receiver (Rx) rather than at that of the transmitter, and the PTE decreases and optimal load increases after considering cross coupling at a short transfer distance. Then the relationship between the coil position and PTE under cross-coupling is discussed, it proves the existence of an optimal transfer distance to achieve the maximum PTE for the symmetric Rxs system, and the dynamic Tx system has an optimal movement range of Tx-coil at the optimal load, so that the system can obtain stable and efficient power transfer when the Tx-coil moves within this range. Finally, the theoretical results are verified through experiments in the lab. Under the optimal operation, an overall efficiency above 75% can be achieved for a system when the Tx-coil moves within this range that the gap of receivers at 100mm.
24 December 2021 in IET Image Processing
Haze usually limits the visibility and reduces the contrast of outdoor images. The removal of haze in a single image has always been a challenging problem. Recently, many methods have been proposed to effectively remove haze in harsh conditions. However, these methods fail to balance the dehazing effect and time consumption. This paper proposes a method based on HSV colour space to restore the visibility of uniform scattering medium. It can prevent the atmospheric light and transmission from being miscalculated. This method uses the brightness component of haze image to estimate the global atmospheric light, which reduces the influence of luminescent objects on atmospheric light estimation. Then, this paper deduces the estimation model of the saturation of scene radiance based on the atmospheric scattering model. In the meantime, according to the advantages and problems of the model, the fast estimation of the transmission is realized by using the stretching function. Finally, this paper solves the parameters in the model by iterative method. Since this method can estimate different media transmission for each pixel, better results can be obtained. The simulation results show that the algorithm is superior to the existing algorithms in terms of dehazing effect and time consumption.