3 June 2015 in Journal of Bone and Joint Surgery
Background: The safe and effective acquisition of microvascular surgical skills is a challenge for any residency program. Variable clinical exposure to microsurgery, premiums on operating room efficiency, and a steep learning curve make these skills difficult to acquire through clinical experience alone. The purpose of this study was to determine the effectiveness of a training curriculum on the development of microvascular surgical skills in our orthopaedic residents. Methods: A microvascular training curriculum was completed during each third-year resident’s rotation on the hand and upper-extremity service. The training cycle began with learning the basics of microvascular surgery on nonliving models and progressed to performing end-to-end arterial anastomoses on a live rat femoral artery in the second session. Outcome evaluations consisted of the Global Rating Scale score, achievement of patency, and time to completion. T test analyses of Global Rating Scale scores, achievement of patency, and time to completion were conducted to determine significance (p < 0.05). Results: All residents significantly improved (p < 0.005) on Global Rating Scale scores from a mean score (and standard deviation) of 15 ± 4 points for the initial score to 20 ± 3 points for the post-test score. Of the twelve residents, patency was achieved by eleven at the final evaluation, compared with six before training. Time to completion of the anastomosis also significantly improved (p < 0.005), from a mean of 37:17 ± 8:41 minutes for the initial time to 24:46 ± 5:32 minutes for the final time. Conclusions: In an effort to improve the microvascular surgical skills of orthopaedic residents at our institution, a microvascular training curriculum was developed and was implemented. This curriculum was effective at improving resident microvascular surgical skills at the completion of an eight-week course.
6 December 2019 in Journal of Bone and Joint Surgery
Background: Neer type-II distal clavicle fractures are unstable and are generally appropriately managed with operative fixation. Fixation options include locking plates, hook plates, and suture button devices. No consensus on optimal technique exists. Methods: A decision tree model was created describing fixation of Neer type-II fractures using hook plates, locking plates, or suture buttons. Outcomes included uneventful healing, symptomatic implant removal, deep infection requiring debridement, and nonunion requiring revision. Weighted averages derived from a systematic review were used for probabilities. Cost-effectiveness was evaluated by calculating incremental cost-effectiveness ratios (ICERs). The ICER is defined as the ratio of the difference in cost and difference in effectiveness of each strategy, and is measured in cost per quality-adjusted life year (QALY). The model was evaluated using thresholds of $50,000/QALY and $100,000/QALY. Sensitivity analysis was performed on all outcome probabilities for each fixation strategy to assess cost-effectiveness across a range of values. Results: Forty-three papers met final inclusion criteria. Using suture buttons as the reference case in the health-care cost model, suture button repair was dominant (both less expensive and clinically superior). Hook plates cost substantially more ($5,360.52) compared with suture buttons and locking plates ($3,713.50 and $4,007.44, respectively). Suture buttons and locking plates yielded similar clinical outcomes (0.92 and 0.91 QALY, respectively). Suture button dominance persisted in the societal perspective model. Sensitivity analysis on outcome probabilities showed that locking plates became the most cost-effective strategy if the revision rate after their use was lowered to 2.2%, from the overall average in the sources of >19%. No other changes in outcome probabilities for any of the 3 techniques allowed suture buttons to be surpassed as the most cost-effective. Conclusions: The cost-effectiveness of suture buttons is driven by low revision rates and high uneventful healing rates. Similar QALY values for locking plate and suture button fixation were observed, which is consistent with existing literature that has failed to identify either as the clinically superior technique. Cost-effectiveness should fit prominently into the decision-making rubric for these injuries. Level of Evidence: Economic Level IV. See Instructions for Authors for a complete description of levels of evidence.
1 March 2022 in The Journal of Hand Surgery
1 March 2019 in JSES Open Access
Olecranon osteotomy is a commonly used method for obtaining adequate exposure of the articular surface in complex distal humeral fractures. We describe a new technique whereby a precontoured olecranon plate is first fixed to the olecranon, and a Gigli saw is used to perform the osteotomy while the plate is in place. By use of a standard posterior approach, a precontoured olecranon plate is applied to the olecranon and affixed with screws both proximally and distally to the planned osteotomy site. A Gigli saw is passed anterior to the olecranon and is used to create an osteotomy through the bare area of the sigmoid notch. The plate is removed from the distal fragment. The proximal olecranon fragment, plate, and extensor mechanism are retracted proximally en bloc to expose the articular surface. After fracture repair, the osteotomy fragments are reapproximated, and the plate is reattached to the distal fragment. QuickDASH (short version of the Disabilities of the Arm, Shoulder and Hand questionnaire) and Veterans RAND 12-Item Health Survey (VR-12) scores for patients treated with this technique were compared with those of patients treated with the standard chevron osteotomy method. All patients achieved radiographic and clinical union of the osteotomy site. QuickDASH, VR-12 physical, and VR-12 mental scores were not significantly different from those of patients in the chevron osteotomy group (P = .93, P = .79, and P = .68, respectively; t test). The described method provides excellent visualization of the joint, is less technically challenging than the standard chevron osteotomy, and reduces operative time. Osteotomy union was attained in all 5 cases, with functional outcomes comparable with those attained with the chevron technique.
14 January 2021 in Current Reviews in Musculoskeletal Medicine
6 April 2022 in Journal of Shoulder and Elbow Surgery