12 June 2020 in IEEE Transactions on Antennas and Propagation
The alias-free field of view (AF-FOV) is inversely proportional to spatial frequency sampling spacing in synthetic aperture interferometric radiometers. When the physical size of antenna elements are large relative to the wavelength, the AF-FOV is limited. This paper focuses on extending the AF-FOV from the perspective of array design. By introducing the sampling spacing compression factor, we define a type of large AF-FOV linear array (LFOVLA) that can generate consecutive spatial frequency samples with sampling spacing less than the minimum antenna spacing. An SA-based algorithm is presented to generate double AF-FOV linear array (DFOVLA), which has the advantage of generating lower redundancy DFOVLA and reducing time cost compared with the previous method. A general pattern method is also proposed to seek large DFOVLA directly. DFOVLA configurations below 26 elements are given. And simulation results show that DFOVLA has a larger AF-FOV than the traditional array in synthetic aperture interferometric radiometers.
1 January 2021 in Geriatric Orthopaedic Surgery & Rehabilitation
Introduction: The aim of this retrospective study was to evaluate the outcomes of older patients with 2-part proximal humerus fractures (PHFs) with medial column disruption stabilized using a proximal humeral internal locking system (PHILOS) plate plus oblique insertion of autologous fibula as a primary procedure. Materials and Methods: Data involving 112 patients (112 shoulders) sustaining 2-part PHFs with medial column disruption treated with PHILOS plate plus oblique insertion of autologous fibula as a primary procedure during 2012-2019 were identified. The median follow-up was 36 months (range: 11.2-43.5 months). The primary endpoint was the Constant scores and American Shoulder and Elbow Surgeons (ASES) scores. The secondary endpoint was the main orthopedic complication rate. Results: The median Constant and ASES scores were 78 (range, 52-95) and 77 (range, 62-96) at the final follow-up, respectively. The main orthopedic complication rate was 10.7% (12/112). Twelve orthopedic complications in 8 patients were detected, and they involved loss of reduction, varus collapse, aseptic loosening, mal-union, revision, and intolerable shoulder pain. Of these complications, 3 (2.6%) involved loss of reduction, 2 (1.7%) involved varus collapse, 3 (2.6%) involved aseptic loosening, 1 (0.8%) involved mal-union, 2 (1.7%) required revision surgery, and 1 (0.8%) presented intolerable shoulder pain. Conclusion: PHILOS plate plus oblique insertion of autologous fibula as a primary procedure may yield good functional outcomes and a low rate of the main orthopedic complications.
11 April 2022 in IEEE Geoscience and Remote Sensing Letters
In the domain of synthetic aperture radiometry, a Fourier transform (FT) relationship can be established between the brightness temperature of the target in the far-field region and the visibility function output by the system. However, when the target is in the near-field range of the imaging system, the existing far-field imaging methods cannot be used directly for the inversion of the near-field visibility function, because the target radiation signal cannot simply be regarded as a plane wave signal. In this letter, we propose a novel imaging method for synthetic aperture radiometer systems on the basis of the characteristics of the near-field target radiation signal. We introduce the near-field error term to reformulate the relationship between visibility function and brightness temperature in near field. Based on the reestablished signal model, we present an image reconstruction algorithm via fractional Fourier transformation, named near-field fractional FT (NF-FRFT), to estimate the near-field brightness temperature. Compared with the conventional near-field imaging method, the proposed NF-FRFT method can achieve better image reconstruction quality without extra hardware consumption. Furthermore, another advantage of this approach is that no additional array layout design is required. The validity of this method is demonstrated by a series of simulations and experiments.
25 September 2019 in IEEE Geoscience and Remote Sensing Letters
Aperture synthesis (AS) passive imaging technique has been proven effective in remote sensing for high resolution. Generally, a synthetic aperture radiometer needs the same number of channels as the antennas. As a consequence, the system complexity, volume, and cost increase rapidly as the size of the array expands. In this letter, the channel compressive AS (CCAS) method is proposed to reduce the receiver channels and correlators. Every channel connects to several different antennas by a selected connection network, and the visibilities are rebuilt from the cross correlation between output signals of the channels. Also, the principles of choosing connection network are discussed to guarantee the performance of the reconstructed brightness temperature (BT) images. Simulation results have shown the validation of the proposed method. It is of great application potential for very large-scale array in the future.