Alice Nova

Alice Nova

Auto-generated profile, based on publicly available information

Alice Nova

Mass General Brigham and Harvard Medical School

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2025 in Journal of Applied Physiology
Verified
Journal Article
Closed access
ANAlice Nova
Alice Nova
YXYi Xin
Yi Xin
MVMarcus Victor
Marcus Victor
TGTimothy G. Gaulton
Timothy G. Gaulton
GAGlasiele C. Alcala
Glasiele C. Alcala
MCMaurizio Cereda
Maurizio Cereda
In a ventilated swine model, we isolated the mechanical effects of mass loading from those of lung injury. Despite optimization, positive end-expiratory pressure (PEEP) could not restore baseline pulmonary compliance or lung volumes in either healthy or injured lungs. Partitioned respiratory mechanics and imaging reveal that geometric constraints and load-induced airway closure, demonstrated here for the first time in injured swine, may limit the effectiveness of recruitment maneuvers and optimized PEEP in mass-loaded lungs.

5 November 2024 in Pulmonology
Verified
Journal Article
Open access
ACAndrea Coppadoro
Andrea Coppadoro
RFRosa Fracchia
Rosa Fracchia
ANAlice Nova
Alice Nova
ARAndrea Restivo
Andrea Restivo
Alberto LucchiniAlberto Lucchini
Alberto Lucchini
GFGiuseppe Foti
Giuseppe Foti
Non-invasive helmet respiratory support is suitable for several clinical conditions. Continuous-flow helmet CPAP systems equipped with HEPA filters have become popular during the recent Coronavirus pandemic. However, HEPA filters generate an overpressure above the set PEEP. A lung simulator was used to mimic patient respiratory mechanics and effort. Compared to room air spontaneous breathing, the additional inspiratory effort attributable to helmet CPAP (ΔPmusHelmet) was recorded at different continuous-flow rates (30-150 L/min), PEEP levels (5, 10, 12.5 cmH2O) and respiratory rates (15, 20, 25, 30 breaths/minute), both with and without a HEPA filter at the outlet port. Helmet pressure swings during inspiration largely explained ΔPmusHelmet variations (p70%) at a 90 L/min flow rate. Higher ΔPmusHelmet levels were recorded when the continuous-flow was lower than the peak inspiratory flow (3.7 [3.1; 5.6] cmH2O, p<0.001) or when a HEPA filter was used (2.7 [2.2; 3.5], p<0.001). Increasing the flow rate resulted in higher overpressure levels, particularly with a HEPA filter (p<0.001). Overpressure levels correlated with ΔPmusHelmet (p<0.001, Spearman's Rho=0.598). Helmet pressure swings below PEEP lead to additional inspiratory efforts. The HEPA filter acts as a flow resistor, generating an overpressure leading to increased respiratory effort. The continuous-flow rate should be titrated high enough to slightly exceed the peak inspiratory flow; however, further flow increase is not recommended as it leads to an increase in overpressure and helmet pressure swings below PEEP.

10 January 2023 in Intensive Care Medicine
Verified
Journal Article
Closed access
PDF file
ANAlice Nova
Alice Nova
EREmanuele Rezoagli
Emanuele Rezoagli
NENilde Eronia
Nilde Eronia
GFGiuseppe Foti
Giuseppe Foti
GBGiacomo Bellani
Giacomo Bellani

13 June 2025 in Biomedical Physics & Engineering Express
Verified
Journal Article
Closed access
MVMarcus Victor
Marcus Victor
ARArthur Ribeiro
Arthur Ribeiro
MMMonica Matsumoto
Monica Matsumoto
YXYi Xin
Yi Xin
ANAlice Nova
Alice Nova
MCMaurizio Cereda
Maurizio Cereda
Objective: Effective lung gas exchange relies on the balance between alveolar ventilation and perfusion, which can be disrupted in mechanically ventilated patients. Lung perfusion assessment using electrical impedance tomography (EIT) typically involves a sudden injection of a hypertonic saline solution. The large field of view provided by EIT often results in ambivalent behavior of many voxel waveforms following an indicator injection, where some exhibit indicator kinetics solely through the lungs (pulmonary), while others show passage through both the heart and lungs (hybrid). Consequently, a segmentation algorithm is essential for accurate perfusion evaluation. Approach: Sixteen pigs (29–35 kg) were mechanically ventilated and received a 10 ml bolus of 7.5% NaCl solution to assess lung perfusion during a healthy stage and, later, in an injured stage after receiving 3.5 ml kg−1 of HCl to induce acute lung injury. Supervised (Bagged Trees, Neural Networks, and Support Vector Machine) and unsupervised (K-means, Hierarchical, and Principal Component Analysis) learning methods were employed using 115 saline injections comprising voxel waveforms to label voxels as either hybrid or pulmonary. All segmentation methods were compared to a ground-truth mask manually drawn. A training dataset (81 injections) was used to train and cross-validate (five-fold) the supervised methods using previously extracted features. The test dataset (34 injections) was used to test both supervised and unsupervised learning algorithms. Main Results: A Principal Component Analysis (unsupervised learning) method exhibited the best overall performance, achieving 83% sensitivity, 92% specificity, 89% accuracy, and 84% dice similarity coefficient. No significant difference in performance was observed between healthy and injured subsets. Unsupervised methods consistently yielded more physiologically plausible and less scattered regions of interest. Significance: Accurate voxel labeling is crucial for lung perfusion assessment, as it enables discrimination of the indicator passage through the heart and lungs, thereby improving the estimation of regional pulmonary blood flow.