Yaping Wu

Yaping Wu

Auto-generated profile, based on publicly available information

Yaping Wu

School of Electrical Engineering, Sichuan University, Chengdu, China

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 December 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
ZTZhirong Tang
Zhirong Tang
KZKai Zhou
Kai Zhou
YXYefei Xu
Yefei Xu
PMPengfei Meng
Pengfei Meng
HZHongzhou Zhang
Hongzhou Zhang
YWYaping Wu
Yaping Wu
The reflection coefficient of reflected wave is one of the most important parameters to characterize the damage degree of power cable defect. However, due to the attenuation and the crossing coupling among the reflection coefficients of each defect, the reflection coefficient of the reflected wave can be hardly estimated, resulting in inaccurate power cable fault diagnosis. Thus, a method based on three-point interpolation fast Fourier transform (FFT) to estimate the reflected amplitude of cable defects is proposed. First, three adjacent points on each spectral peak in the frequency domain are selected to accurately analyze the exponential signal in the frequency domain, and gain the parameters including the amplitude and phase of the reflected wave at the defect. Then, the state of the defect is evaluated by the reflection coefficient at the defect. Finally, the simulation result shows both the amplitude and phase relative errors of the proposed method are less than 10%, meanwhile the experiment results prove the proposed method can accurately judge the state of the cable defect.

15 March 2023 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
YWYaping Wu
Yaping Wu
KZKai Zhou
Kai Zhou
SLSiyan Lin
Siyan Lin
ZWZikang Wang
Zikang Wang
YCYidong Chen
Yidong Chen
YFYao Fu
Yao Fu
In this study, the inhibition effect of electrical treeing is investigated in a cross-linked polyethylene (XLPE) cable under the targeted movement of rejuvenation fluid induced by an electric field. First, the fluid concentration around the defects is characterized by Fourier transform infrared spectroscopy (FTIR) under different voltages, application durations, and application temperatures. These results show that with increasing applied voltage, application duration and temperature, the fluid concentration around the defects increases nonlinearly. Next, the electrical treeing features of samples with and without electric field induction show that the tree initiation voltage increases and the tree accumulated damage decreases for the samples with electric field induction. By analyzing the changes in the molecular chain structure of the XLPE under different influencing factors, it is found that with applied voltage and duration increase and application temperature decreases, the methyl groups increase and the methylene groups decrease, the diffusion channel of fluid is expanded. Finally, it is proposed that the dielectrophoretic (DEP) force, changes in molecular chain structure, and molecular thermal motion determine the behaviors of the targeted movement of fluid in insulation. The fluid concentration around the defects increases after the targeted movement of fluid, and the electrical treeing inhibition effect is enhanced.