Paediatric trigger finger is a rare condition distinct from paediatric trigger thumb and adult trigger digits. We performed a systematic review of paediatric trigger finger presentation and aetiology in order to guide workup and management. Fifty-one studies with 193 patients and 398 trigger fingers were included. Most patients had a single, unilateral trigger finger (54%). Fifty-five patients (29%) had an underlying condition, such as mucopolysaccharidosis; these cases appeared to be associated with multiple or bilateral trigger fingers or with carpal tunnel syndrome. All patients with mucopolysaccharidosis were treated surgically. Conservative management was reported in 33% of all patients, and two-thirds of these did not need further intervention. Patients undergoing surgical release infrequently had recurrence of triggering (6%). We propose an algorithmic approach for patients presenting with paediatric trigger finger. Presence of bilateral or multiple trigger digits or concomitant carpal tunnel syndrome should raise suspicion for an atypical underlying pathology.
Background: Manual axon histomorphometry (AH) is time- and resource-intensive, which has inspired many attempts at automation. However, there has been little investigation on implementation of automated programs for widespread use. Ideally such a program should be able to perform AH across imaging modalities and nerve states. AxonDeepSeg (ADS) is an open source deep learning program that has previously been validated in electron microscopy. We evaluated the robustness of ADS for peripheral nerve axonal histomorphometry in light micrographs prepared using two different methods. Methods: Axon histomorphometry using ADS and manual analysis (gold-standard) was performed on light micrographs of naïve or regenerating rat median nerve cross-sections prepared with either toluidine-resin or osmium-paraffin embedding protocols. The parameters of interest included axon count, axon diameter, myelin thickness, and g-ratio. Results: Manual and automatic ADS axon counts demonstrated good agreement in naïve nerves and moderate agreement on regenerating nerves. There were small but consistent differences in measured axon diameter, myelin thickness and g-ratio; however, absolute differences were small. Both methods appropriately identified differences between naïve and regenerating nerves. ADS was faster than manual axon analysis. Conclusions: Without any algorithm retraining, ADS was able to appropriately identify critical differences between naïve and regenerating nerves and work with different sample preparation methods of peripheral nerve light micrographs. While there were differences between absolute values between manual and ADS, ADS performed consistently and required much less time. ADS is an accessible and robust tool for AH that can provide consistent analysis across protocols and nerve states.
Background: Radial head fractures are often associated with poor outcomes. Both open reduction and internal fixation (ORIF) and radial head arthroplasty (RHA) might be considered in operative cases. This study aimed to compare long-term patient-reported functional outcomes among patients with operatively treated radial head fractures. Methods: A cross sectional study conducted at a Level I trauma center was used to identify patients with a radial head fracture who underwent ORIF or RHA between 2006 and 2018, and agreed to complete a survey in 2020. The primary outcome measure was the Quick Disabilities of the Arm, Shoulder, and Hand (QuickDASH) score. Results: Seventy-six patients participated in the study. No significant differences in outcomes were observed between groups. QuickDASH scores were similar for both groups (ORIF: mean = 15.7, SD = 18.4; RHA: mean = 22.8, SD = 18.6; mean difference = 0.2 [-9.0 to 9.3], P = .97). Nineteen (37%) ORIF patients and 12 (48%) RHA patients reported a need for pain medication (adjusted odds ratio [OR] = 0.8 [0.3-2.4], P = .70). Thirteen (25%) ORIF patients and 6 (24%) RHA patients required additional surgery (adjusted OR = 1.7 [0.5-6.2], P = .39). A subgroup analysis of multi-fragmentary fractures revealed similar findings. Conclusion: Patient-reported outcomes, which included a subgroup analysis of multi-fragmentary fractures, were similar between ORIF and RHA groups at an average of 7.5 years from surgery. Reconstructing the radial head might not result in worse outcomes than RHA when both options are employed according to the best judgment of the operating surgeon.
1 May 2018 in Medical Devices: Evidence and Research
Background: One of the greatest barriers to safe surgery is the availability of functional biomedical equipment. Biomedical technicians play a major role in ensuring that equipment is functional. Following in-field observations and an online survey, a mobile application was developed to aid technicians in troubleshooting biomedical equipment. It was hypothesized that this application could be used to aid technicians in equipment repair, as modeled by repair of a pulse oximeter. Methods: To identify specific barriers to equipment repair and maintenance for biomedical technicians, an online survey was conducted to determine current practices and challenges. These findings were used to guide the development of a mobile application system that guides technicians through maintenance and repair tasks. A convenience sample of technicians in Ethiopia tested the application using a broken pulse oximeter task and following this completed usability and content validity surveys. Results: Fifty-three technicians from 13 countries responded to the initial survey. The results of the survey showed that technicians find equipment manuals most useful, but these are not easily accessible. Many do not know how to or are uncomfortable reaching out to human resources. Thirty-three technicians completed the broken pulse oximeter task using the application. All were able to appropriately identify and repair the equipment, and post-task surveys of usability and content validity demonstrated highly positive scores (Agree to Strongly Agree) on both scales. Discussion: This research demonstrates the need for improved access to resources for technicians and shows that a mobile application can be used to address a gap in the access to knowledge and resources in low- and middle-income countries. Further research will include prospective studies to determine the impact of an application on the availability of functional equipment in a hospital and the effect on the provision and safety of surgical care.