Owing to its low cost and ease of manufacture, integrated monocular space camera and laser rangefinders are commonly used in many space applications (i.e., pose measurement of non-cooperative targets). This and other composite systems estimate poses with high precision using a combination of high-resolution lateral visual and high-precision distance information. Notably, any system that is tested on ground must again receive precise on-orbit calibration because the accompanying spaceborne turntables and arms must be frequently manipulated to meet field-of-view and distance measurement requirements and require complicated realignments. To accommodate flexible multiple target calibration, this study proposed an on-orbit model that obtains accurate pose relationships jointly using the monocular camera and laser rangefinder. First, we invented a robust calibration model and derive its pose transformation matrix based on the given component positions. We then provided an improved (simplified) orthogonal iteration algorithm that optimizes the given matrix for calibration. The influences of different factors on calibration accuracy are quantitatively analyzed via simulations, and the new method’s performance is verified with real-world experiments. This system enables several novel and significant space and military applications.
Object tracking is one of the most important fields in computer vision and image processing community. In this paper, a novel method for tracking of moving object is proposed. We analyze many methods which are used to segment the Video Object (VO). Then we propose a way, which is based on optical flow, to track object by using the object contour. This algorithm achieves the effective object tracking in spatial position. The experiment result shows that moving object tracking is accurate, rapid and stable by using this algorithm.
A non-contact blood pressure measurement method was proposed and achieved based on theoretical deduction of the relationship among pulse transit time, heart rate and blood pressure. Pulse transit time was estimated using heart rate and phase difference of pulse wave which were obtained from color videos through imaging photoplethysmographic. Parameters of the functional relationship were determined through curve fitting with experiment data. Error analysis was processed with an Omron electronic sphygmomanometer as reference to verify the accuracy of blood pressure obtained using the proposed method. The error of acquired systolic blood pressure varied from -2.40 to 3.43 percent. The error of acquired diastolic blood pressure varied from -6.88 to 5.26 percent.