Michael Anthony Stone

Michael Anthony Stone

Auto-generated profile, based on publicly available information

Michael Anthony Stone

The University of Manchester

Research Focus & Metrics

Academic Career Length

36Years (1991-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 January 2015 in Frontiers in Aging Neuroscience
Verified
Journal Article
Open access
PDF file
Christian FüllgrabeChristian Füllgrabe
Christian Füllgrabe
BMBrian C. J. Moore
Brian C. J. Moore
MSMichael A. Stone
Michael A. Stone
Hearing loss with increasing age adversely affects the ability to understand speech, an effect that results partly from reduced audibility. The aims of this study were to establish whether aging reduces speech intelligibility for listeners with normal audiograms, and, if so, to assess the relative contributions of auditory temporal and cognitive processing. Twenty-one older normal-hearing (ONH; 60-79 years) participants with bilateral audiometric thresholds ≤ 20 dB HL at 0.125-6 kHz were matched to nine young (YNH; 18-27 years) participants in terms of mean audiograms, years of education, and performance IQ. Measures included: (1) identification of consonants in quiet and in noise that was unmodulated or modulated at 5 or 80 Hz; (2) identification of sentences in quiet and in co-located or spatially separated two-talker babble; (3) detection of modulation of the temporal envelope (TE) at frequencies 5-180 Hz; (4) monaural and binaural sensitivity to temporal fine structure (TFS); (5) various cognitive tests. Speech identification was worse for ONH than YNH participants in all types of background. This deficit was not reflected in self-ratings of hearing ability. Modulation masking release (improvement in speech identification obtained by amplitude modulating a noise background) and spatial masking release (benefit obtained from spatially separating masker and target speech) were not affected by age. Sensitivity to TE and TFS was lower for ONH than YNH participants, and was correlated positively with speech-in-noise (SiN) identification. Many cognitive abilities were lower for ONH than YNH participants, and generally were correlated positively with SiN identification scores. The best predictors of the intelligibility of SiN were composite measures of cognition and TFS sensitivity. These results suggest that declines in speech perception in older persons are partly caused by cognitive and perceptual changes separate from age-related changes in audiometric sensitivity.

1 February 2008 in The Journal of the Acoustical Society of America
Verified
Journal Article
Closed access
PDF file
KHKathryn Hopkins
Kathryn Hopkins
BMBrian C. J. Moore
Brian C. J. Moore
MSMichael A. Stone
Michael A. Stone
Speech reception thresholds (SRTs) were measured with a competing talker background for signals processed to contain variable amounts of temporal fine structure (TFS) information, using nine normal-hearing and nine hearing-impaired subjects. Signals (speech and background talker) were bandpass filtered into channels. Channel signals for channel numbers above a “cut-off channel” (CO) were vocoded to remove TFS information, while channel signals for channel numbers of CO and below were left unprocessed. Signals from all channels were combined. As a group, hearing-impaired subjects benefited less than normal-hearing subjects from the additional TFS information that was available as CO increased. The amount of benefit varied between hearing-impaired individuals, with some showing no improvement in SRT and one showing an improvement similar to that for normal-hearing subjects. The reduced ability to take advantage of TFS information in speech may partially explain why subjects with cochlear hearing loss get less benefit from listening in a fluctuating background than normal-hearing subjects. TFS information may be important in identifying the temporal “dips” in such a background.

1 July 2012 in The Journal of the Acoustical Society of America
Verified
Journal Article
Closed access
MSMichael A. Stone
Michael A. Stone
Christian FüllgrabeChristian Füllgrabe
Christian Füllgrabe
BMBrian C. J. Moore
Brian C. J. Moore
Stone et al. [J. Acoust. Soc Am. 130, 2874–2881 (2011)], using vocoder processing, showed that the envelope modulations of a notionally steady noise were more effective than the envelope energy as a masker of speech. Here the same effect is demonstrated using non-vocoded signals. Speech was filtered into 28 channels. A masker centered on each channel was added to the channel signal at a target-to-background ratio of −5 or −10 dB. Maskers were sinusoids or noise bands with bandwidth 1/3 or 1 ERBN (ERBN being the bandwidth of “normal” auditory filters), synthesized with Gaussian (GN) or low-noise (LNN) statistics. To minimize peripheral interactions between maskers, odd-numbered channels were presented to one ear and even to the other. Speech intelligibility was assessed in the presence of each “steady” masker and that masker 100% sinusoidally amplitude modulated (SAM) at 8 Hz. Intelligibility decreased with increasing envelope fluctuation of the maskers. Masking release, the difference in intelligibility between the SAM and its “steady” counterpart, increased with bandwidth from near-zero to around 50 percentage points for the 1-ERBN GN. It is concluded that the sinusoidal and GN maskers behaved primarily as energetic and modulation maskers, respectively.

1 June 1999 in Ear & Hearing
Verified
Journal Article
Closed access
MSMichael A. Stone
Michael A. Stone
BMBrian C. J. Moore
Brian C. J. Moore
When people who wear hearing aids speak, there are three paths by which they hear their own voices: 1) through the air and leakage around the earmold; 2) via the solid structures of their head; 3) through the air to the hearing aid microphone, and then through the aid circuitry. These paths involve different time delays. Digital processing introduces delays in path 3 from a few to several tens of milliseconds, which could lead to a range of disturbing effects. We examined one purely auditory effect, namely hearing speech through all three of these paths. Subjective disturbance was measured as a function of delay in path 3 using simulations of hearing loss and a simulated hearing aid. With increasing hearing loss, the loudness of sound heard via paths 1 and 2 decreases, and the aid user relies more on path 3. The disturbance produced by the delay then might be less perceptible. To test this idea, four different hearing losses were simulated, varying from mild to moderately severe. Each of two talkers was fitted with a closed earmold, and simultaneous above-ear and in-ear recordings were made of each talker reading prose. The above-ear signal was amplified using a simulated hearing aid with 4-channel full dynamic range compression; compression ratios and gains were selected using an algorithm based on the absolute thresholds used in the simulations of hearing loss. The resultant output was then mixed with the in-ear signal with one of five values of delay, and the combined signal was processed using the four simulations of hearing loss. The resulting stimuli simulated for normal-hearing listeners the experience of having a hearing impairment and listening through a hearing aid while talking, except that the talker’s voice was not that of the listener. Twenty normally hearing subjects gave subjective ratings of the disturbance of the echo for each delay and each simulated hearing loss. Disturbance ratings generally increased monotonically with increasing delay. Average results show that delays are rated as “disturbing” for values between 20 and 30 msec for mild to moderate losses. For a moderately severe loss, the rating “disturbing” was not quite achieved at 40 msec. For moderate losses, a speaker with low fundamental frequency (f0)(70 to 140 Hz) was less disturbing than a speaker with a medium f0, (100 to 180 Hz). This effect reversed for the mildest loss for low values of delay. The auditory effects of delays between bone-conducted sound and aid-conducted sound are likely to become disturbing for delays exceeding 20 msec. Somewhat longer delays may be tolerable for moderate to severe hearing losses. These delays are smaller than the delays at which audio-visual integration is disrupted.

1 October 2004 in Ear & Hearing
Verified
Journal Article
Closed access
BMBrian C. J. Moore
Brian C. J. Moore
BGBrian R. Glasberg
Brian R. Glasberg
MSMichael A. Stone
Michael A. Stone
To develop a new version of the threshold-equalizing-noise (TEN) test for the diagnosis of dead regions, with levels calibrated in dB HL rather than dB SPL, and with levels corresponding to the dial readings on the audiometer. The spectral shape of the noise required to give equal masked thresholds at all frequencies, when expressed in dB HL, was derived by two calculation methods and by empirical measurements of the electrical output of audiometers using TDH50 earphones and TDH39 earphones. To reduce the loudness of the noise and to minimize distortion generated in the audiometer and/or earphone, the noise was bandlimited between 354 and 6500 Hz. In addition, the noise was synthesized using a method that leads to a low crest factor (ratio of peak to root-mean-square value). This further reduced audiometer/earphone distortion and allowed higher levels per ERBN; ERBN is the equivalent rectangular bandwidth of the auditory filter at 1 kHz, as determined in young, normally hearing subjects. The test tone frequencies were limited to the range 500 to 4000 Hz. Subjects with normal or near-normal hearing were tested by using a noise level of 60 dB HL/ERBN to assess whether the noise did lead to equal masked thresholds in dB HL for all audiometric frequencies from 500 to 4000 Hz. Thresholds in the TEN were measured by means of manual audiometry with a 2 dB final step size. The mean masked thresholds were almost constant across frequency when expressed in dB HL and were within 0.5 dB of the noise level per ERBN. For a single noise level, the test takes approximately 5 minutes per ear to administer. The new TEN test has the following advantages over the original version (which used levels calibrated in dB SPL): (1) All levels are expressed in dB HL. Thus, absolute thresholds only need to be measured once. (2) Calibration is such that both the noise level/ERBN and the test tone levels correspond to the values indicated on the audiometer. This makes the test simpler to apply and reduces the likelihood of errors. (3) The noise bandwidth is restricted, and the noise has a low crest factor. This allows the noise level/ERBN to be increased while avoiding distortion, excessive loudness, and possible further damage to hearing.

29 January 2010 in International Journal of Audiology
Verified
Journal Article
Closed access
PDF file
BMBrian Cecil Joseph Moore
Brian Cecil Joseph Moore
BGBrian R. Glasberg
Brian R. Glasberg
MSMichael A. Stone
Michael A. Stone
<!--RIDCIT0033--> 33. Moore B.C.J., Glasberg B.R., Stone M.A. 1999b. Use of a loudness model for hearing aid fitting. III. A general method for deriving initial fittings for hearing aids with multi-channel compression. Br J Audiol, 33, 241–258. [Taylor & Francis Online], [PubMed] View all references described a procedure, CAMEQ, for the initial fitting of multi-channel compression hearing aids. The procedure was derived using a model of loudness perception for impaired hearing. We describe here the development of a new fitting method, CAMEQ2-HF, which differs from CAMEQ in the following ways: (1) CAMEQ2-HF gives recommended gains for centre frequencies up to 10 kHz, whereas the upper limit for CAMEQ is 6 kHz; (2) CAMEQ is based on the assumption that the hearing aid user faces the person they wish to hear and uses a free-field-to-eardrum transfer function for frontal incidence. CAMEQ2-HF is based on the assumption that the user may wish to hear sounds from many directions, and uses a diffuse-field-to-eardrum transfer function; (3) CAMEQ2-HF is based on an improved loudness model for impaired hearing; (4) CAMEQ2-HF is based on recent wideband measurements of the average spectrum of speech. Sumario <!--RIDCIT0033--> 33. Moore B.C.J., Glasberg B.R., Stone M.A. 1999b. Use of a loudness model for hearing aid fitting. III. A general method for deriving initial fittings for hearing aids with multi-channel compression. Br J Audiol, 33, 241–258. [Taylor & Francis Online], [PubMed] View all references describieron un procedimiento, CAMEQ, para la adaptación inicial de auxiliares auditivos con compresión de múltiples canales. El procedimiento se basó en el uso de un modelo de percepción de la intensidad subjetiva para casos de audición disminuida. Describimos aquí el desarrollo de un nuevo método de adaptación, CAMEQ2-HF, que difiere del CAMEQ en las siguientes formas: (1) CAMEQ2-HF proporciona ganancias recomendadas para las frecuencias centrales hasta 10 kHz mientras que el límite superior para el CAMEQ es 6 kHz; (2) CAMEQ se basa en la suposición de que el usuario de un auxiliar auditivo (se ubica de frente)hace frente a la persona que quiere oír y usa la función de transferencia campo libre-membrana timpánica para una incidencia frontal. CAMEQ2-HF se basa en la suposición de que el usuario quiere oír los sonidos desde muchas direcciones y usa una función de transferencia campodifuso-a-membrana timpánica; (3) CAMEQ2-HF se basa en un modelo de intensidad subjetiva mejorada para la audición disminuida; (4) CAMEQ2-HF se basa en las recientes mediciones de banda ancha del espectro promedio del habla.