Rayane Sebold

Rayane Sebold

Auto-generated profile, based on publicly available information

Rayane Sebold

Cardiopulmonary Physiotherapy Laboratory, Physiotherapy Department, Federal University of Sao Carlos, Sao Paulo, Brazil

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2020 in International Journal of Chronic Obstructive Pulmonary Disease
Verified
Journal Article
Open access
PDF file
PCPatrícia Faria Camargo
Patrícia Faria Camargo
LDLuciana Ditomaso-Luporini
Luciana Ditomaso-Luporini
LJLuiz Carlos Soares de Carvalho Jr
Luiz Carlos Soares de Carvalho Jr
Cássia Da Luz GoulartCássia Da Luz Goulart
Cássia Da Luz Goulart
RSRayane Sebold
Rayane Sebold
ASAudrey Borghi e Silva
Audrey Borghi e Silva
Background: The heart rate (HR) kinetics as well as other predictors of functional capacity such as the Chronic Obstructive Pulmonary Disease (COPD) Assessment Test (CAT), the Duke Activity Status Index (DASI) and the handgrip strength (HGS) represent important tools in assessing the impact of COPD on exercise performance and health status of individuals with COPD. Purpose: To verify the relationship between functional capacity, measured using the six-minute walking test (6MWT), with the HR off-kinetics, HGS and the DASI and CAT scores. Methods: For this cross-sectional study, 29 subjects with COPD underwent body composition, pulmonary function and cardiac function tests. Subsequently, the DASI and CAT questionnaires and HGS test were performed. The beat-to-beat R-R intervals (IRR) were collected in rest, during the test and in recovery after the 6MWT. The HR off-kinetics was obtained during a 360-second period in post-exercise recovery through the HR mono-exponential decay. Results: Moderate correlations were observed between: 1) walked distance (WD) in the 6MWT and the CAT and DASI scores (r= − 0.58, p=0.001 and r= 0.58, p=0.001, respectively); 2) WD and HGS (r=0.37, p=0.05); 3) and WD and HR off-kinetics (τ; r= − 0.54, p=0.002 and MRT; r= − 0.55, p=0.002, respectively). Conclusion: The 6MWT performance is a direct measurement to evaluate functional capacity. Additionally, it is related to other direct and indirect markers for functional evaluation in patients with COPD. These results suggest the application of these tools in clinical practice, based on the accessibility, non-invasive character and easy applicability of these methods.