Ilya Bendich

Ilya Bendich

Auto-generated profile, based on publicly available information

Ilya Bendich

Department of Orthopedic Surgery, Washington University in St. Louis, St. Louis, MO, USA

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

4 September 2020 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
IBIlya Bendich
Ilya Bendich
NZNing Zhang
Ning Zhang
JBJeffrey J. Barry
Jeffrey J. Barry
DWDerek T. Ward
Derek T. Ward
MWMary A. Whooley
Mary A. Whooley
AKAlfred C. Kuo
Alfred C. Kuo
Background: It is controversial whether the use of antibiotic-laden bone cement (ALBC) in primary total knee arthroplasty (TKA) affects periprosthetic joint infection (PJI) or revision rates. The impact of ALBC on outcomes of primary TKA have not been previously investigated in U.S. veterans, to our knowledge. The purposes of this study were to quantify utilization of ALBC among U.S. veterans undergoing primary TKA and to determine if ALBC usage is associated with differences in revision TKA rates. Methods: Patients who had TKA with cement from 2007 to 2015 at U.S. Veterans Health Administration (VHA) hospitals with at least 2 years of follow-up were retrospectively identified. Patients who received high-viscosity Palacos bone cement with or without gentamicin were selected as the final study cohort. Patient demographic and comorbidity data were collected. Revision TKA was the primary outcome. All-cause revisions and revisions for PJI were identified from both VHA and non-VHA hospitals. Unadjusted and adjusted regression analyses were performed to identify variables that were associated with increased revision rates. Results: The study included 15,972 patients who had primary TKA with Palacos bone cement at VHA hospitals from 2007 to 2015. Plain bone cement was used for 4,741 patients and ALBC was used for 11,231 patients. Utilization of ALBC increased from 50.6% in 2007 to 69.4% in 2015. At a mean follow-up of 5 years, TKAs with ALBC had a lower all-cause revision rate than those with plain bone cement (5.3% versus 6.7%; p = 0.0009) and a lower rate of revision for PJI (1.9% versus 2.6%; p = 0.005). On multivariable regression, ALBC use was associated with a lower risk of all-cause revision compared with plain bone cement (hazard ratio [HR]: 0.79, 95% confidence interval [CI]: 0.68 to 0.92; p = 0.0019). Seventy-one primary TKAs needed to be implanted with ALBC to avoid 1 revision TKA. Conclusions: The utilization of ALBC for primary TKAs performed at VHA hospitals has increased over time and was associated with a lower all-cause revision rate and a lower rate of revision for PJI. Level of Evidence: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

3 July 2024 in The Journal of Arthroplasty
Verified
Journal Article
Closed access
DMDavid A. Momtaz
David A. Momtaz
Daniel Enrique PereiraDaniel Enrique Pereira
Daniel Enrique Pereira
ASAaron Singh
Aaron Singh
RGRishi Gonuguntla
Rishi Gonuguntla
MMMehul M. Mittal
Mehul M. Mittal
IBIlya Bendich
Ilya Bendich

21 September 2024 in The Journal of Arthroplasty
Verified
Journal Article
Closed access
JGJoseph T. Gibian
Joseph T. Gibian
WZWilliam A. Zuke
William A. Zuke
HHHunter Hood
Hunter Hood
EBEthan Blum
Ethan Blum
RNRyan M. Nunley
Ryan M. Nunley
IBIlya Bendich
Ilya Bendich

17 December 2024 in HIP International
Verified
Journal Article
Closed access
IBIlya Bendich
Ilya Bendich
YCYu-Fen Chiu
Yu-Fen Chiu
NSNana Sarpong
Nana Sarpong
AVAlejandro Gonzalez Della Valle
Alejandro Gonzalez Della Valle
ESEdwin Su
Edwin Su
AMAlexander McLawhorn
Alexander McLawhorn
Introduction: The use of technology in direct anterior approach (DAA) total hip arthroplasty (THA) is expanding. Although the use of computer-navigation (CN-THA) and robotics (RA-THA) has previously demonstrated improved component positioning, it is important to understand whether its use is associated with differences in intraoperative complications or early return to the operating room when compared to fluoroscopy-only (manual-THA) DAA THA. Methods: 3433 DAA THAs (226 RA-THA, 1007 CN-THA, 2200 manual-THA) performed at a single institution were retrospectively reviewed. Cohorts were adjusted for age, sex, BMI, femoral fixation, history of spine fusion, and Charlson Co-morbidity Index (CCI) using Inverse Probability of Treatment Weight (IPTW). Operative times were identified. Intraoperative fractures and re-operations within 1 year were identified via chart review. Results: There were no statistically significant differences in intraoperative fracture among the cohorts (0.4% RA-THA, 0.4% CN-THA, 0.4% manual-THA; p > 0.529). There were also no statistically significant differences ( p > 0.589) among the cohorts in rates of return to the operating room within 1 year for postoperative fracture (0.0% RA-THA, 0.4% CN-THA, 0.4% manual-THA), dislocation (0.0% RA-THA, 0.0% CN-THA, 0.1% manual-THA), infection (0.4% RA-THA, 0.7% CN-THA, 0.5% manual-THA), or other aetiologies (0.0% RA-THA, 0.2% CN-THA, 0.1% manual-THA). Conclusions: This study did not find a statistically significant difference in intraoperative fracture or re-operations within 1 year between DAA THA performed with RA, CN, or manual techniques. The introduction of technology to THA is not associated with increase in reoperations within one-year.

1 January 2025 in JBJS Essential Surgical Techniques
Verified
Journal Article
Closed access
MSMaria Schwabe
Maria Schwabe
JGJoseph T. Gibian
Joseph T. Gibian
KBKimberly A. Bartosiak
Kimberly A. Bartosiak
IBIlya Bendich
Ilya Bendich
ASAndrew M. Schneider
Andrew M. Schneider
Background: Robotic-assisted total hip arthroplasty (THA) through the posterior approach is indicated in cases of symptomatic hip arthritis. The goal of the procedure is to relieve pain and restore function while minimizing postoperative complications such as dislocation. Dislocation often occurs despite traditionally well placed components 1,2 . The hip-spine relationship can be a causative factor in postoperative instability, particularly in patients with altered spinopelvic kinematics as a result of spinal fusions or degenerative spine disease, in whom component placement based on anatomic landmarks may lead to functional malpositioning 3,4 . Therefore, we present our technique for robotic-assisted THA through the posterior approach, which incorporates patient-specific spinopelvic kinematic data to maximize impingement-free range of motion and minimize the risk of dislocation. Description: Preoperative computed tomography (CT) scans are obtained in order to generate a 3D model of the patient’s unique hip anatomy. Lateral lumbar radiographs with the patient in the sitting and standing positions are also obtained preoperatively. The sacral slope is measured in each position, imported into the robotic software, and utilized to aid in positioning the components for optimal leg length, offset, and stability of the hip replacement based on the patient’s unique spino-kinematic profile. The procedure begins with 3 partially threaded pins being driven into the ipsilateral iliac crest about 2 cm posterior to the anterior superior iliac spine. The robotic pelvic array is fastened to the pins. A standard posterior approach to the hip is utilized. Skin and subcutaneous tissues are dissected down to the iliotibial band and gluteus maximus fascia. The fascia is longitudinally incised, and a small metallic pin is malleted into the distal aspect of the greater trochanter. Initial leg length and offset values are captured. The short external rotators and posterior hip capsule are elevated. The hip is dislocated, and a neck resection is made at a level determined preoperatively with use of the robotic software. The acetabulum is exposed, and osseous registration is carried out to establish a relationship between the 3D model built with use of the robotic software and the patient’s anatomy in vivo. The acetabulum is single-reamed, and the final cup is impacted in the desired position. The proximal femur is broached with increasingly sized broaches until rotational and axial stability has been achieved. A trial femoral neck and head are attached to the final broach, and the hip is reduced. Posterior and anterior hip stability are assessed, and leg length and offset are rechecked via the robotic system. Once the surgeon is satisfied, the hip is dislocated, the broach is removed, and the final femoral stem and head are manually implanted. The hip is then reduced for the final time. Closure is performed according to surgeon preference. Alternatives: Surgical alternatives include THA with use of manual instrumentation or navigation through other approaches to the hip, including the direct anterior, anterolateral, and direct lateral approaches 5–7 . Nonoperative alternatives include physical therapy, the use of nonsteroidal anti-inflammatory pain medication, and intra-articular corticosteroid injections 8 . Rationale: Robotic-assisted THA is particularly advantageous in patients with abnormal spinopelvic kinematics who require precise and specific component positioning to optimize hip stability 9–11 . In these patients, manually placing components relative to anatomic landmarks may lead to functional malpositioning and ultimately dislocation. Additionally, cases in which there is an anticipated difficulty in acetabular exposure or preparation because of a large body habitus or large pannus, retained acetabular hardware, or severe acetabular wear or dysplasia may benefit from the use of this technique 9 . Expected Outcomes: Patients who undergo robotic-assisted THA through the posterior approach should expect excellent clinical outcomes in addition to low rates of complication and revision12. Robotic-assisted THA has been shown to lower the risk of dislocation compared with manual techniques 10,11 . In a study by Bendich et al., a robotic-assisted THA cohort had a 0.3 odds ratio of reoperation for dislocation compared with a manual THA cohort 10 . Important Tips: Stable array pins are critical in order to obtain accurate leg length and offset measurements intraoperatively. When registering the acetabulum via the robotic software, aim for maximum spread of captured points to ensure accuracy of cup placement. In large-statured patients or patients with a particularly stiff hip, in whom anterior femoral retraction is difficult, disconnect the reamer from the robotic arm and place it into the acetabulum by hand before reconnecting it to the robotic arm. Remove the anterior acetabular retractor and set the reaming orientation to 50° of inclination and 10° of anteversion. Final cup position is kept in the desired orientation. Remember that the robotic-assistance device is just a surgical tool, and the quality of its output relies on the quality of its input. If there is concern for an error in component placement, intraoperative radiographs should be obtained. Acronyms and Abbreviations: THA = total hip arthroplasty CT = computed tomography DVT = deep vein thrombosis IT = iliotibial