Gul Sirin Ustabasi

Gul Sirin Ustabasi

Auto-generated profile, based on publicly available information

Gul Sirin Ustabasi

Istanbul Technical University

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 June 2019 in Environmental Monitoring and Assessment
Verified
Journal Article
Closed access
PDF file
GUGul Sirin Ustabasi
Gul Sirin Ustabasi
ABASLI BAYSAL
ASLI BAYSAL


21 December 2017 in Environmental Monitoring and Assessment
Verified
Journal Article
Closed access
PDF file
ABASLI BAYSAL
ASLI BAYSAL
Hasan SayginHasan Saygin
Hasan Saygin
GUGul Sirin Ustabasi
Gul Sirin Ustabasi

1 September 2021 in Journal of the Electrochemical Society
Verified
Journal Article
Closed access
GUGul S. Ustabasi
Gul S. Ustabasi
MOMustafa Ozcan
Mustafa Ozcan
IYIsmail Yilmaz
Ismail Yilmaz
Determination of heavy metals is still a relevant pursuit due to the ongoing incidents of contamination and continuous anthropogenic and industrial activities. Spectrometric methods such as atomic absorption are the most common approaches to this task because of the high accuracy and sensitivity they provide. Nevertheless, these methods are costly, time-consuming, and do not allow for on-site measurements. Considering recent developments in electrochemistry, especially voltammetric methods, conducting trace-level heavy metal analysis has become easier, faster, and cheaper. Utilizing a carbon-based electrode (CBE) for this purpose seems to further improve the performance of the above-mentioned methods. CBEs are versatile, offer a wide potential window, and possess desirable conductive and surface properties that allow sensitive determination of analytes. This review aims to examine the recent studies published between 2015 and 2020 which investigated the performance of carbon-based electrodes in heavy metal determination, by placing the four most common carbon electrodes to the center: glassy carbon electrode, graphite electrode, carbon paste electrode, and screen-printed carbon electrode.

29 October 2018 in Bulletin of Environmental Contamination and Toxicology
Verified
Journal Article
Closed access
PDF file
ABASLI BAYSAL
ASLI BAYSAL
Hasan SayginHasan Saygin
Hasan Saygin
GUGul Sirin Ustabasi
Gul Sirin Ustabasi

24 June 2015 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
NONil Ozbek
Nil Ozbek
GUGul Sirin Ustabasi
Gul Sirin Ustabasi
SASuleyman Akman
Suleyman Akman
In this study, lead concentrations in various plastic toys were determined directly by solid sampling high resolution continuum source graphite furnace atomic absorption spectrometry. The toys were cut into small pieces and introduced into the graphite furnace between 0.05 and 0.7 mg without any further treatment. Lead was determined at 217.005 nm using a Pd + Mg modifier. The samples were pyrolyzed at 1000 °C and atomized at 2200 °C with or without gas flow at the atomization stage depending on the concentration of the analyte. The lead concentration in a certified reference plastic material (ERM-EC680K) was determined in the uncertainty limits of the certified value. The limits of detection in gas-stop and gas-flow modes for 0.7 mg of sample were 0.037 and 0.93 mg kg−1, respectively. The concentrations of lead in plastic toys of different colours were found to be in the range of 0.060–9.12 mg kg−1.