13 November 2023 in IEEE Sensors Journal
This research addresses the long-term measurement of environmental data in geographically remote areas and an energy-optimized method of storing data on a storage medium. For this purpose, we have developed our measurement module ADL - Advanced Data Logger. In terms of connectivity, the module operates in 3 modes: offline - when measured data is primarily stored on the storage medium; IoT ready - measured data is stored on the storage medium and sent to the remote server in defined batches; online mode - when measured data is preferably sent to the remote server immediately after measurement. The design aims to minimize the module’s power consumption so that the autonomous operating time is close to one year. As part of the design, the simpleFS software module is designed for the role of a simple file system optimized to minimize I/O operations. Its other feature in data storage is the automatic normalization of the data transmitted from the attached sensors. The last part of the design is the AdlReader software solution, used to configure the hardware (HW) module and to retrieve the measured data files. We verified the correct operation of the ADL module along with nine sensors built in a vertical soil temperature profile probe in experimental installation and operation for two months. According to the requirements for our solution, the expected operation time of the ADL module is 9 - 12 months.
1 September 2016 in Current Directions in Biomedical Engineering
The fetal oxygen saturation is an important parameter to determine the health status of a fetus, which is until now mostly acquired invasively. The transabdominal, fetal pulse oximetry is a promising approach to measure this non-invasively and continuously. The fetal pulse curve has to be extracted from the mixed signal of mother and fetus to determine its oxygen saturation. For this purpose efficient algorithms are necessary, which have to be evaluated under constant and reproducable test conditions. This paper presents the improved version of a phantom which can generate artificial pulse waves in a synthetic tissue phantom. The tissue phantom consists of several layers that mimic the different optical properties of the fetal and maternal tissue layers. Additionally an artificial vascular system and a dome, which mimics the bending of the belly of a pregnant woman, are incorporated. To obtain data on the pulse waves, several measurement methods are included, to help understand the behavior of the signals gained from the pulse waves. Besides pressure sensors and a transmissive method we integrated a capacitive approach, that makes use of the so called “Pin Oscillator” method. Apart from the enhancements in the tissue phantom and the measurements, we also improved the used blood substitute, which reproduces the different absorption characteristics of fetal and maternal blood. The results show that the phantom can generate pulse waves similar to the natural ones. Furthermore, the phantom represents a reference that can be used to evaluate the algorithms for transabdominal, fetal pulse oximetry.
1 June 2013 in Research Papers Faculty of Materials Science and Technology Slovak University of Technology
This paper deals with the light transport, photon trajectory and its radiation in tissue. A model based on Monte Carlo simulation has been implemented in Matlab to get inside into photon interaction with tissue. The project is aimed to non-invasive pulse oximetry measurement of fetal oxygen saturation in the maternal abdomen. One of the fundamental challenges is to ensure a sufficient penetration depth which covers maternal and fetal tissue. This contribution investigates the photon trajectories and analyse the number of photons which stayed in tissue and their radiation distribution. The principle and photon propagation rules, needed for simulation, are presented in this article. Finally the results are compared with literature.
1 September 2016 in Current Directions in Biomedical Engineering
Transabdominal fetal pulse oximetry is an approach to measure oxygen saturation of the unborn child non-invasively. The principle of pulse oximetry is applied to the abdomen of a pregnant woman, such that the measured signal includes both, the maternal and the fetal pulse curve. One of the major challenges is to extract the shape of the fetal pulse curve from the mixed signal for computation of the oxygen saturation. In this paper we analyze the principle kind of connection of the fetal and maternal pulse curves in the measured signal. A time varying finite element model is used to rebuild the basic measurement environment, including a bulk tissue and two independently pulsing arteries to model the fetal and maternal blood circuit. The distribution of the light fluence rate in the model is computed by applying diffusion equation. From the detectors we extracted the time dependent fluence rate and analyzed the signal regarding its components. The frequency spectra of the signals show peaks at the fetal and maternal basic frequencies. Additional signal components are visible in the spectra, indicating multiplicative coupling of the fetal and maternal pulse curves. We conclude that the underlying signal model of algorithms for robust extraction of the shape of the fetal pulse curve, have to consider additive and multiplicative signal coupling.