Martin Tanner

Martin Tanner

Auto-generated profile, based on publicly available information

Martin Tanner

Tofwerk AG, Uttigenstrasse 22, CH-3600 Thun, Switzerland

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 March 2010 in Geostandards and Geoanalytical Research
Verified
Journal Article
Closed access
PDF file
LSLuigi A. Solari
Luigi A. Solari
AGArturo Gómez‐Tuena
Arturo Gómez‐Tuena
JBJuan Pablo Bernal
Juan Pablo Bernal
OPOfelia Pérez‐Arvizu
Ofelia Pérez‐Arvizu
MTMartin Tanner
Martin Tanner

7 November 2012 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
OBOlga Borovinskaya
Olga Borovinskaya
BHBodo Hattendorf
Bodo Hattendorf
MTMartin Tanner
Martin Tanner
SGSabrina Gschwind
Sabrina Gschwind
DGDetlef Günther
Detlef Günther
A prototype inductively coupled plasma time-of-flight mass spectrometer (ICPTOFMS) for time resolved measurements of transient signals in the microsecond regime is described in this work. Analytical figures of merit for the prototype are given for both liquid nebulization and single droplet introduction and are compared to a conventional quadrupole-based ICPMS using the same ICP source and vacuum interface. Quasi-simultaneous detection at a time resolution of 33 μs of the prototype ICPTOFMS allows multi-isotope monitoring of short signals (200–500 μs duration) generated from individual droplets and particles. The capabilities of the instrument for the analysis of single nanoparticles are studied using microdroplets consisting of a multi-element standard solution and containing 114 nm Au particles. The detection efficiencies for Ag and Au, calculated from the response of individual droplets and particles, are similar to those of the quadrupole-based instrument and amount to 1.3 × 10−6 ions per atom and 3.1 × 10−6 ions per atom, respectively. The sizes of the smallest detectable Ag, Au and U metallic nanoparticles are estimated to be 46 nm, 32 nm and 22 nm, respectively. Furthermore, time shifts of the signals of different elements within single droplets were observed. These new results demonstrate the advantage of the temporal resolution of the instrument for studying processes taking place in the plasma on the μs-time scale.

11 July 2014 in Analytical Chemistry
Verified
Journal Article
Closed access
OBOlga Borovinskaya
Olga Borovinskaya
SGSabrina Gschwind
Sabrina Gschwind
BHBodo Hattendorf
Bodo Hattendorf
MTMartin Tanner
Martin Tanner
DGDetlef Günther
Detlef Günther

1 February 2009 in Analytica Chimica Acta
Verified
Journal Article
Closed access
MTMartin Tanner
Martin Tanner
DGDetlef Günther
Detlef Günther

18 January 2010 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
MTMartin Tanner
Martin Tanner
Signal to noise ratios of transient signals depend on the signal duration and are usually better for shorter signals. Poisson distribution is the dominating noise source for mass spectrometers at low count numbers. The IUPAC concept of ‘detection limit’ is used as a measure of the noise level and three different ways of detection limit calculations are compared and discussed. Assumption of Normal distribution leads to underestimation of the detection limit compared to exact Poisson based calculations. A simple formula given by IUPAC bases detection limit on the standard deviation of the blank but introduces a term to correct for the difference between Normal and Poisson distributions. Results of this formula are comparable to exact Poisson calculations. Signal to noise in transient signals was evaluated. It was found that an optimum duration for transient signals exists and that it depends on the level of the instrument background.

30 January 2008 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Closed access
PDF file
MTMartin Tanner
Martin Tanner
DGDetlef Günther
Detlef Günther