Witold Mikulski

Witold Mikulski

Auto-generated profile, based on publicly available information

Witold Mikulski

Centralny Instytut Ochrony Pracy - Państwowy Instytut Badawczy / Central Institute for Labour Protection - National Research Institute, Warszawa, Poland (Zakład Zagrożeń Wibroakustycznych / Department of Vibroacoustic Hazards).

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2010 in Archives of Acoustics
Verified
Journal Article
Closed access
PDF file
DADanuta Augustyńska
Danuta Augustyńska
AKAnna Kaczmarska
Anna Kaczmarska
WMWitold Mikulski
Witold Mikulski
JRJan Radosz
Jan Radosz

1 December 2011 in Archives of Acoustics
Verified
Journal Article
Open access
PDF file
WMWitold Mikulski
Witold Mikulski
JRJan Radosz
Jan Radosz
The article presents results of our own research regarding acoustic properties of 110 classrooms in five typical primary schools in Warsaw. The target of the research was to assess the classrooms using established criteria. These criteria include the reverberation time and the speech transmission index. The research has shown a large diversity of acoustic properties of classrooms within each of the schools and between the schools, resulting from the classroom equipment and the school building construction. In addition, the assessment has indicated that classrooms in schools researched do not meet the established acoustic criteria (reverberation time and speech transmission index). Because the classroom equipment is different for younger forms (integrated teaching) and for older forms (subject teaching), the results have been analyzed separately for rooms for younger forms (0-III) and for rooms for older forms (IV-VI). Synthetic results prove the advisability of such division. Correlation analysis has been conducted for the speech transmission index STI and reverberation time Tmf, as well as for the speech transmission index STI and the suggested reverberation time Twf defined in a similar manner as Tmf, but in a wider frequency range. The correlation between the speech transmission index STI and Twf is higher than that between the STI index and Tmf. The reverberation time Twf can therefore be used for a more precise assessment of acoustic properties of interiors with regard to verbal communication than Tmf. In addition, the paper presents estimated analysis results of the influence of selected classroom equipment (carpets) on its acoustic properties.

1 June 2013 in Archives of Acoustics
Verified
Journal Article
Closed access
PDF file
WMWitold Mikulski
Witold Mikulski
Sound absorption coefficient is a commonly used parameter to characterize the acoustic properties of sound absorbing materials. It is defined within the frequency range of 100-5 000 Hz. In the industrial conditions, many appliances radiating acoustic energy of the frequency range of above 5000 Hz are used and at the same time it is known that a noise within the frequency range of 5 000-50 000 Hz can have a harmful effect on people,hence there is a need to define the coefficient in this frequency range. The article presents a proposal for a method of measurement of the sound absorption coefficient of materials in the frequency range from 5 000 Hz to 50 000 Hz. This method is a modification of the reverberation method with the use of interrupted noise.

15 October 2020 in Journal of Environmental Health Science and Engineering
Verified
Journal Article
Open access
PDF file
WMWitold Mikulski
Witold Mikulski
Purpose: The purpose of the research is to work out a method for determining the sound insulation of acoustic enclosures for industrial sources emitting noise in the frequency range of 10–40 kHz and apply the method to measure the sound insulation of acoustic enclosures build of different materials. Methods: The method is developed by appropriate adaptation of techniques applicable currently for sound frequencies of up to 10 kHz. The sound insulation of example enclosures is determined with the use of this newly developed method. Results: The research results indicate that enclosures (made of polycarbonate, plexiglass, sheet aluminium, sheet steel, plywood, and composite materials) enable reducing the sound pressure level in the environment for the frequency of 10 kHz by 19–25 dB with the reduction increasing to 40–48 dB for the frequency of 40 Hz. The sound insulation of acoustic enclosures with a sound-absorbing material inside reaches about 38 dB for the frequency of 10 kHz and about 63 dB for the frequency of 40 kHz. Conclusion: Some pieces of equipment installed in the work environment are sources of noise emitted in the 10–40 kHz frequency range with the intensity which can be high enough to be harmful to humans. The most effective technical reduction of the associated risks are acoustic enclosures for such noise sources. The sound pressure level reduction obtained after provision of an enclosure depends on its design (shape, size, material, and thickness of walls) and the noise source frequency spectrum. Realistically available noise reduction values may exceed 60 dB.

1 December 2018 in Strojnícky časopis - Journal of Mechanical Engineering
Verified
Journal Article
Open access
PDF file
DPDariusz PLEBAN
Dariusz PLEBAN
MWMikulski Witold
Mikulski Witold
Two test stands for determining sound insulation in the frequency range above 5 kHz were made. One consisted of two horizontally adjacent reverberation rooms and a special source of high frequency sounds and ultrasounds. The other test stand consisted of a miniaturized test chamber and a special source of ultrasounds. The paper presents results of the preliminary measurements of sound insulation properties of different barriers in the frequency range above 5 kHz.

8 March 2018 in Medycyna Pracy
Verified
Journal Article
Open access
WMWitold Mikulski
Witold Mikulski
Background: Noise in open plan offices should not exceed acceptable levels for the hearing protection. Its major negative effects on employees are nuisance and impediment in execution of work. Specific technical solutions should be introduced to provide proper acoustic conditions for work...