16 August 2020 in Tuberculosis and Lung Diseases
The objective of the study: to compare the degree of lung damage according to chest CT data to the clinical state of COVID-19 patient, to analyze the semiotics and changes in CT data. Subjects and methods. 317 CT scans were retrospectively analyzed; those scans belonged to 98 patients with COVID-19 treated at N.V. Sklifosovsky Research Institute for Emergency Medicine. Patients were divided into 4 groups, depending on the degree of the lungs damage detected by CT during the primary examination, their clinical state was assessed at each subsequent CT scan. To determine the relationship between the degree of pulmonary changes and the clinical status of patients, a correlation analysis was performed using the rank correlation method, significance was assessed using the Student's coefficient. Results. It was found that CT allowed to identify changes in the lungs typical of COVID-19 and assess their degree, as well as to analyze progression or regression lung changes, including comparison with clinical data. A significant correlation was revealed (rs = 0.577) between the growing degree of lung damage, as determined by CT and deterioration of the clinical status of patients.
20 April 2021 in Russian Sklifosovsky Journal "Emergency Medical Care"
BACKGROUND Fractures of the proximal humerus are more common in older adults. Two options for surgical treatment of the same fractures are routinely performed — primary arthroplasty and osteosynthesis with metal fixators. Both methods are most effective in elderly patients for augmentation of the proximal humerus. For this purpose, methyl methacrylate cement or bone allo-/autografts are used. However, the incidence of unsatisfactory functional results after surgery remains high.AIM OF STUDY To develop allogeneic graft to strengthen the proximal humerus in the osteosynthesis of a comminuted fracture with a lack of bone tissue which has osteoconductive properties and capable of being a carrier of biologically active substances.MATERIAl AND METHODS The head, neck and portion of diaphysis of a fibula of a cadaver were used for a graft. The graft 6–8 cm long was formed and saturated with a collagen solution. Ten patients with 4-fragment fractures of the proximal humerus underwent surgery. X-rays and computed tomography of the operated joint were performed the day after surgery, and then, 6 weeks, 6 months, and one year after the surgery. The follow-up period ranged from 6 to 18 months.RESUlTS When evaluating osteoconductive effect in cell culture during saturation with collagen, the content cells on the surface of bone was 5–8 thousand/cm2 and 16–18 thousand/cm2 on the sample, saturated with plasma and growth factors. The studied bone grafts were biocompatible and non-toxic for fibroblast culture. On the surface of the bone graft without collagen adhesion of minimum number of cells occurred. After saturation of the graft with collagen, the adhesive activity of cells on the bone matrix increased, which indicated the presence of an osteoconductive effect. The addition of plasma saturated with growth factors promoted an increase in the number of adhered cells; therefore, the graft can be used as a carrier of biologically active substances. Postoperative X-ray didn’t reveal secondary varus displacement of the head in any patient (except for ununiformed fracture case).CONClUSION The developed graft is non-toxic, does not possess immunogenicity, has more pronounced osteoconductive properties in comparison with native bone allografts, which contributes to its colonization with cells. The use of such a graft in clinical practice makes it possible to achieve healing of the fracture and prevent secondary displacement of fragments.
1 January 2018 in Russian Electronic Journal of Radiology
SMSklifosovsky Research and Clinical Institute for Emergency Medicine
Sklifosovsky Research and Clinical Institute for Emergency Medicine
11 December 2024 in Bulletin of the Medical Institute "REAVIZ" (REHABILITATION, DOCTOR AND HEALTH)
The purpose of the study: to clarify the possibilities of using X-ray research methods in the framework of a comprehensive diagnosis of gastrointestinal fistulas in pancreatic necrosis.Materials and methods. The analysis of the results of X-ray examination of 23 patients with pancreatic necrosis complicated by the formation of gastrointestinal tract fistulas (GI tract) is presented. All patients underwent computed tomography (CT) of the abdominal cavity and retroperitoneal space with bolus contrast enhancement and X-ray fistulography. Contrast examination of the upper gastrointestinal tract after oral administration of a water-soluble contrast agent and CT fistulography were used as additional research methods.Results. During the examination, 27 gastrointestinal fistulas were detected in 23 patients. In all 23 patients, CT examination revealed signs of pancreatic necrosis and parapancreatitis with the presence of fluid and necrotic accumulations that were drained. CT scan revealed indirect signs of gastrointestinal fistulas, such as: the location of the gastrointestinal tract bearing the fistula in the zone of pancreatogenic destruction (100%), thickening of the intestinal wall or stomach (100%), gas inclusions in adjacent sections of fiber (59%). Direct signs of gastrointestinal fistulas were detected by X-ray fistulography in 22 cases (81%) in the form of leakage of CA into the lumen of the intestine or stomach. In 5 patients (19%) with fistula of the duodenum, there were no direct signs of fistula during fistulography. In almost all of these observations (21 cases out of 22 95%), fistulography revealed a cavity of pancreatogenic destruction through which the fistula communicated with the intestine or stomach. At the stages of pancreatic necrosis treatment, CT monitoring was performed in all 23 patients to identify new areas of necrosis and fluid accumulations, and to assess the location of drainage tubes in relation to the intestinal wall. Dynamic X-ray fistulography (20 observations) was used to evaluate the effectiveness of treatment of fistula and the state of the destruction cavity.Conclusion. X-ray fistulography makes it possible to diagnose gastrointestinal fistulas in patients with pancreatic necrosis with a sensitivity of 81% in general and 100% when the fistula is localized in the colon. To increase the information content in the detection of small intestinal fistulas, it is advisable to use an X-ray contrast examination of the gastrointestinal tract. At the same time, CT additionally allows you to assess the condition of the pancreatic parenchyma and parapancreatic fiber, and determine therapeutic tactics. X-ray monitoring using CT and X-ray fistulography is an integral component of the therapeutic and diagnostic algorithm in patients with gastrointestinal fistulas in pancreatic necrosis.
18 May 2021 in Medical Visualization
The purpose of the study. To analyze possibilities of computed tomography (CT) for esophageal injuries and their complications as part of a differentiated approach to the choice of a minimally invasive treatment method. Materials and methods. The results of CT scans were analyzed in 25 patients with esophageal injuries of various etiologies who were treated at the N.V. Sklifosovsky Research Institute of SP in the period 2019–2020. CT was performed with oral and intravenous bolus contrast, primarily at admission and in dynamics, a total of 77 studies. Results. In all cases, direct and indirect CT signs of esophageal damage were detected, and the degree of involvement of surrounding organs and tissues in the pathological process was assessed. Based on the data obtained, the following variants of esophageal damage and its complications were identified: intramural esophageal hematoma (2); rupture of the thoracic esophagus without the development of purulent complications (2); rupture of the thoracic esophagus complicated by the development of mediastinitis (4); rupture of the thoracic esophagus with the development of mediastinitis and pleural empyema (13); rupture of the cervical calving of the esophagus, complicated by phlegmon of the neck and descending mediastinitis (4). Different patient management tactics were used for each variant. Thus, the selection and sequence of minimally invasive interventions, such as thoracoscopic sanitation mediastinal and pleural cavity, esophageal stenting, percutaneous endoscopic gastrostomy (CEG) and endoscopic vacuum aspiration system (E-VAS), were carried out taking into account CT data, including observations in dynamics. Conclusion. CT scan for esophageal injuries allows you to get complete information about both the nature of esophageal damage and its complications, to determine their type, localization and volume. CT data allow us to justify a minimally invasive approach in the treatment of esophageal injuries, to determine the order of interventions. CT studies performed in dynamics allow us to evaluate the effectiveness of treatment and to carry out timely correction of tactics.
1 January 2018 in Russian Electronic Journal of Radiology
SMSklifosovsky Research and Clinical Institute for Emergency Medicine
Sklifosovsky Research and Clinical Institute for Emergency Medicine
IUI.M. Sechenov First Moscow State Medical University
I.M. Sechenov First Moscow State Medical University