3 September 2021 in IEEE Access
Active discharge circuit is of great significance for discharging the dc-bus capacitor voltage to safe voltage in the electric vehicles (EVs) based PMSM drive system when EVs encounter an emergency such as a crash event. However, when electric vehicle occurs a collision, the active discharge circuit may be damaged or failed, which poses a great electric threat to the passengers and succors. In order to resolve the problem, this article proposes a winding-based dc-bus capacitor discharge method. To quickly discharge the dc-bus capacitor energy, the machine windings are used as discharge resistance with active discharge circuit fault. For the purpose of reducing the bus voltage to safe voltage as soon as possible, the discharge method can be divided into two phases, rapid discharge stage and bus voltage regulation stage. Firstly, the dc-bus voltage will be dropped to safe voltage due to the large flux-weakening current applied to the d-axis. Secondly, in order to stabilize the bus voltage at safe voltage, an extended observer state (ESO) is designed to estimate and compensate the total power loss that is regarded as disturbance in bus voltage regulation stage. The parameters of the proposed ESO are designed and the tracking performance is analyzed. Finally, the proposed discharge technique is validated by both simulation and experiments, which are conducted on a three-phase SPMSM drive platform.
14 September 2021 in IEEE Access
To prevent the passengers from electric shock, the DC-bus capacitor voltage of the high-voltage permanent magnet synchronous machine (PMSM)-based drives in electric vehicles (EVs) is required to decline to safe voltage as quickly as possible when emergency occurs. Considering that the discharge time for small safe current limit powertrain systems will be longer than required, this paper proposed a maximum power discharge strategy to accelerate the dissipating process and meanwhile avoid the voltage surge. Firstly, the PMSM discharge model as a generator is established on the basis of analyzing the discharge course. Secondly, the feasible reference current trajectory is presented by drawing the trajectories of the voltage, current, and power constraints. Then the maximum power discharge strategy is achieved by following the extreme points in the reference trajectory. Finally, simulation and experiment are conducted on a three-phase SPMSM powertrain system to validate the proposed algorithm can effectively shorten the discharge process.