Chunxiao Li

Chunxiao Li

Auto-generated profile, based on publicly available information

Chunxiao Li

Department of Ultrasound, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200080, China

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 April 2020 in British Journal of Radiology
Verified
Journal Article
Closed access
XLXin Li
Xin Li
FGFeng Gao
Feng Gao
FLFan Li
Fan Li
XHXiao-Xia Han
Xiao-Xia Han
SSSi-Hui Shao
Si-Hui Shao
LDLianfang Du
Lianfang Du
Objective: To evaluate the performance of contrast-enhanced ultrasound in the diagnosis of small, solid, TR3–5 benign and malignant thyroid nodules (≤1 cm). Methods: From January 2016 to March 2018, 185 thyroid nodules from 154 patients who underwent contrast enhanced ultrasound (CEUS) and fine-needle aspiration or thyroidectomy in Shanghai General Hospital were included. The χ2 test was used to compare the CEUS characteristics of benign and malignant thyroid nodules, and the CEUS features of malignant nodules assigned scores. The total score of the CEUS features and the scores of the above nodules were evaluated according to the latest 2017 version of the Thyroid Imaging Reporting and Data System (TI-RADS). The diagnostic performance of the two were compared based on the receiver operating characteristic curves generated for benign and malignant thyroid nodules. Results: The degree, enhancement patterns, boundary, shape, and homogeneity of enhancement in thyroid small solid nodules were significantly different (p<0.05). No significant differences were seen between benign and malignant thyroid nodules regarding completeness of enhancement and size of enhanced lesions (p>0.05). The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of the TI-RADS classification TR5 in diagnosis of malignant nodules were 90.10%, 55.95%, 74.59%, 72.22%, and 82.46%, respectively (area under the curve [AUC]=0.738; 95% confidence interval[CI], 0.663–0.813). The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of the total score of CEUS qualitative analysis indicators were 86.13%, 89.29%, 87.57%, 90.63%, and 84.27% respectively (AUC = 0.916; 95% CI, 0.871–0.961). Conclusion: CEUS qualitative analysis is superior to TI-RADS in evaluating the diagnostic performance of small, solid thyroid nodules. Qualitative analysis of CEUS has a significantly higher specificity for diagnosis of malignant thyroid nodules than TI-RADS. Advances in knowledge: The 2017 version of TI-RADS has recently suggested the malignant stratification of thyroid nodules by ultrasound. In this paper we applied this system and CEUS to evaluate 185 nodules and compare the results with pathological findings to access the diagnostic performance.

7 April 2020 in British Journal of Radiology
Verified
Journal Article
Closed access
CLChunxiao Li
Chunxiao Li
MYMinghua Yao
Minghua Yao
SSSihui Shao
Sihui Shao
XLXin Li
Xin Li
GLGang Li
Gang Li
RWRong Wu
Rong Wu
Objective: This study aimed to compare the diagnostic performance of contrast-enhanced ultrasound (CEUS), MRI, and the combined use of the two modalities for differentiating breast lesions of different sizes. Methods: A total of 406 patients with 406 solid breast masses detected by conventional ultrasound underwent both CEUS and MRI scans. Histological results were used as reference standards. The lesions were categorized into three groups according to size (Group 1, ≤ 20 mm; Group 2, > 20 mm, Group 3: total lesions). Sensitivity, specificity, accuracy, and receiver operating characteristic (ROC) curve analysis were used to assess the diagnostic performance of these imaging methods for breast lesions. Results: There were 194 benign and 212 malignant breast lesions according to the histological diagnosis. Compared with MRI, CEUS demonstrated similar sensitivity in detecting breast cancer (p = 1.0000 for all) in all the three groups. With regard to specificity, accuracy, and the area under the ROC curve (Az) values, MRI showed a better performance than that shown by CEUS (p <0.05 for all), and the combination of the two modalities improved the diagnostic performance of CEUS alone significantly (p <0.05 for all) in all the three groups. However, the diagnostic specificity and accuracy of the combined method was not superior to that of MRI alone except for Group 2. Conclusion: CEUS demonstrated good sensitivity in detecting breast cancer, and the combined use with MRI can optimize the diagnostic specificity and accuracy in breast cancer prediction. Advances in knowledge: Few studies have compared the diagnostic efficacy of CEUS and MRI, and this study is the first attempt to seek out the diagnostic values for breast lesions of variable sizes (lesions with ≤20 mm and >20 mm).

1 November 2021 in British Journal of Radiology
Verified
Journal Article
Open access
YBYun Bai
Yun Bai
JLJun Lin
Jun Lin
ACAn Chen
An Chen
MBMin Bai
Min Bai
CLChunxiao Li
Chunxiao Li
FLFan Li
Fan Li
Objective: To compare the diagnostic value of contrast-enhanced ultrasonography (CEUS) with baseline ultrasound (B-US) in ureteral neoplasms. Methods: Retrospective analysis, comprising clinical presentation, image appearances, and diagnostic results on B-ultrasound and CEUS, considering pathological result as a gold-standard, was conducted on the clinical information of 39 patients with ureteral neoplasms. CT urography was used to detect and confirm the presence of ureteral neoplasms. Both B-ultrasound and CEUS investigations of those 39 patients under study were performed by a senior radiologist. Results: Pathological outcomes established 27 ureteral malignancies and 12 ureteral benignancies. Ureteral malignancies were observed to occur in older patients than benignancies (p = 0.002). Only the morphological indicator of the ureteric wall on B-ultrasound was different in ureteral malignancies and benignancies (p = 0.030). Tumors with hyperenhancement, larger width, and hyperenhanced ureteric wall were easily diagnosed as malignant on CEUS, whereas iso-/hypoenhanced, narrower, and iso-/hypoenhanced ureteric wall indicated benign tumors. Moreover, the lesion widths, enhanced morphologies of the ureteric wall, and the ureteral wall’s linear boundaries on CEUS were different between high- and low-stage ureteral urothelial carcinomas (p = 0.012, 0.002, 0.001, respectively). Conclusion: The display of microvessels in ureteral neoplasms was significantly enhanced by CEUS, thus contributing to the differential diagnosis of ureteral neoplasms while assisting the staging of ureteral urothelial carcinoma. Advances in knowledge: The imaging features of different ureteral neoplasms on CEUS were analyzed in this study. The diagnostic performances of CEUS and B-ultrasound in ureteral urothelial carcinomas were also explored.

27 April 2022 in Journal of Clinical Ultrasound
Verified
Journal Article
Closed access
CLChunxiao Li
Chunxiao Li
MYMinghua Yao
Minghua Yao
XLXin Li
Xin Li
SSSihui Shao
Sihui Shao
JCJing Chen
Jing Chen
RWRong Wu
Rong Wu

22 July 2021 in British Journal of Radiology
Verified
Journal Article
Closed access
YCYingyu Cai
Yingyu Cai
FLFan Li
Fan Li
ZLZhaojun Li
Zhaojun Li
XLXin Li
Xin Li
CLChunxiao Li
Chunxiao Li
RWRong Wu
Rong Wu
Objective: This study aimed to develop a model to predict the risk of malignancy in solid renal parenchymal lesions based on the imaging features of combined conventional and contrast-enhanced ultrasound (CEUS). Methods: A retrospective review was performed among patients with focal solid renal parenchymal lesions on ultrasound images. Ultrasound features were characterized by two experienced radiologists independently. A multiple logistic regression analysis was performed to determine the most relevant features and to estimate the risk of malignancy. Scoring and counting methods were developed based on the most relevant features. The diagnostic performance was evaluated by the sensitivity, specificity, positive predictive value, negative predictive value and area under the receiver operating characteristic curve (AUC). Results: A total of 519 renal lesions were included in this study. The conventional ultrasound features of diameter, echogenicity, hypoechoic rim and the CEUS feature of heterogeneity were identified as the most relevant features for prediction of malignancy. The sensitivity and specificity for the logistic regression model, the scoring method and the counting method were 95.3 and 93.4%, 93.8 and 87.8%, 88.8 and 93.9%, respectively. The logistic model had the best performance for diagnosing malignant renal lesions with AUC of 0.978, compared with the scoring method and the counting method with AUCs of 0.958 and 0.965. Conclusion: The combination of contrast-enhanced ultrasound with conventional ultrasound improved the diagnostic performance of solid renal lesions based on the logistic regression model. Advances in knowledge: In this study, we revealed that the combination of CEUS and conventional ultrasound provided higher accuracy for diagnosing malignant renal tumors.