Alan Wong

Alan Wong

Auto-generated profile, based on publicly available information

Alan Wong

Department of Cardiovascular Disease, The Christ Hospital, Cincinnati, Ohio, USA

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 March 2024 in Vascular Medicine
Verified
Journal Article
Closed access
AWAlan Wong
Alan Wong
ASAditya Sharma
Aditya Sharma
RRRandy Ramcharitar
Randy Ramcharitar
Erdheim–Chester disease (ECD) is a rare ‘L’ (Langerhans) group histiocytic neoplasm that affects a multitude of organ systems, causing osteosclerotic bone lesions, periaortic encasement (‘coated’ aorta), retroperitoneal fibrosis involving kidneys and ureters (‘hairy kidney’), and infiltration of the central nervous system. Cardiovascular involvement can occur in up to 70% of patients and is usually found during computed tomography/magnetic resonance imaging evaluation. When present, cardiovascular symptoms can have wide variability in presentation from asymptomatic to pericarditis, fatal cardiac tamponade, myocardial infarction, conduction abnormalities, heart failure, renal artery stenosis, and claudication. Cardiac involvement found on imaging includes right atrial pseudotumor, right atrioventricular groove infiltration, and pericardial effusions. ECD can involve the large- and medium-sized arteries, often seen as periarterial thickening (commonly coating the aorta) with stenosis/occlusion. Although more cardiovascular ECD cases have begun to be published in the literature, more data are needed on the outcomes of these patients, as well as how cardiovascular manifestations respond to treatment of ECD.

2 May 2025 in Journal of the Society for Cardiovascular Angiography & Interventions
Verified
Journal Article
Open access
HBHanad Bashir
Hanad Bashir
GHGustavo Mendez Hirata
Gustavo Mendez Hirata
CSChristian W. Schmidt
Christian W. Schmidt
AWAlan Wong
Alan Wong
JMJanelle Muuse
Janelle Muuse
SGSantiago Garcia
Santiago Garcia
Aortic regurgitation (AR) is a common complication in patients with left ventricular assist devices (LVAD). However, there is paucity of data regarding the feasibility and safety of transcatheter aortic valve replacement (TAVR) in this population. Hence, we sought to describe the clinical characteristics and outcomes of patients with LVAD and AR who underwent treatment with TAVR at our institution. We included all patients with a LVAD who developed clinically significant AR and received TAVR at The Christ Hospital in Cincinnati, Ohio. Baseline clinical and echocardiographic characteristics were collected, and outcomes were defined using Valve Academic Research Consortium 3 criteria. A total of 7 patients with LVAD were included. The median time from LVAD implantation to TAVR was 3.67 years (IQR, 1.96-4.26 years). The mean age of the patients was 68.6 ± 13.7 years, and the average Society of Thoracic Surgeons score was 6.2 ± 5.2. All patients presented with moderate to severe AR and New York Heart Association functional class III or IV symptoms. All procedures were performed via transfemoral access, with a median procedure time of 149 minutes (IQR, 146-150 minutes). The transcatheter heart valves implanted included commercially available devices—Abbott Navitor (n = 2) and Medtronic Evolut (n = 3)—and dedicated investigational devices for AR—JenaValve Trilogy (n = 1) and J-Valve (n = 1). All patients were discharged alive with no or mild residual AR. There was 1 case of device embolization, which was treated with a second valve, and 1 valve migration treated with snaring and repositioning of the valve. Both complications occurred in patients treated with commercially available self-expanding valves. TAVR for AR in selected patients with LVAD is a feasible therapeutic option that may improve outcomes. Larger studies are necessary to better define procedural risks, optimal patient selection, and the role of TAVR valves specifically designed for AR in this population.

2 May 2025 in Journal of the Society for Cardiovascular Angiography & Interventions
Verified
Journal Article
Open access
HBHanad Bashir
Hanad Bashir
AWAlan Wong
Alan Wong
JMJanelle Muuse
Janelle Muuse
CSChristian W. Schmidt
Christian W. Schmidt
GHGustavo Mendez Hirata
Gustavo Mendez Hirata
JCJohn D. Corl
John D. Corl
Calcium modification techniques have improved the outcomes of endovascular treatment for severely calcified stenotic lesions. In contrast to balloon angioplasty and modified balloons, intravascular lithotripsy (IVL) modifies both superficial and deep vascular calcium by delivering pulsatile sonic energy, which creates circumferential and longitudinal fractures with subsequent optimization of therapies such as stent implantation. We describe the clinical and procedural characteristics, as well as outcomes, from our initial experience with the Shockwave Javelin peripheral IVL catheter (Shockwave Medical), a novel forward IVL platform designed for difficult-to-cross calcified lesions. The first 10 patients treated with this catheter at our institution (The Christ Hospital, Cincinnati, Ohio) were included. The primary outcome was device success, defined as the ability to deliver and advance across the target lesion, pressurize, pulse, flush, and retrieve the Javelin IVL catheter. Safety outcomes included in-hospital death and procedural complication rates. A total of 16 lesions in 10 patients were analyzed following IVL therapy using the Javelin device. The mean age at the time of the procedure was 74.1 ± 7.6 years. Of the 10 patients, 4 were classified as Rutherford class III, 1 as Rutherford class IV, and 5 as Rutherford class V. Additionally, 9 of 16 lesions were chronic total occlusions. All 16 lesions exhibited significant arterial calcification, with grade 3 (19%) or grade 4 (81%) calcification based on the Peripheral Arterial Calcium Scoring System (PACSS), which quantifies the severity of arterial calcification to guide treatment planning. Device success was achieved in 15/16 lesions. All patients received the maximum allowable 120 pulses with the Javelin catheter. None of the patients required a second Javelin device, but 3 of 16 lesions were treated with additional balloon-based IVL catheters. Three everolimus-eluting resorbable scaffolds were placed across 3 lesions (all below the knee). Drug-coated balloons were utilized in 5 of 16 lesions (all above the knee). Following forward IVL with the Javelin device, no arterial dissections were observed, and 3 arterial dissections occurred following subsequent balloon dilatation, none of which resulted in residual dissection after resorbable scaffold implantation. No in-hospital mortality or other postprocedural complications were noted. The Javelin peripheral IVL catheter appears to demonstrate high device success rates in real-world complex peripheral arterial stenoses and safely facilitates access to additional therapies. Further studies are required to better define the safety and effectiveness of Javelin IVL treatment for heavily calcified peripheral lesions.

23 October 2025 in JACC: Case Reports
Verified
Journal Article
Open access
AWAlan Wong
Alan Wong
RGRaviteja Guddeti
Raviteja Guddeti
MSMuhammad Saad
Muhammad Saad
GRGrayson Rohmiller
Grayson Rohmiller
DMDeven Marathe
Deven Marathe
SGSantiago Garcia
Santiago Garcia
Our objective was to describe a transcatheter approach to treat severe tricuspid regurgitation and paravalvular regurgitation from a partially dehisced surgical ring. The procedure was performed under general anesthesia with transesophageal echocardiogram guidance. Femoral vein access with Swan-Ganz catheter (Edwards Lifesciences) was advanced to the right pulmonary artery (PA). Lunderquist wire (Cook Medical) was advanced through the Swan-Ganz catheter (Edwards Lifesciences). A 65-cm 26-F DrySeal sheath (W.L. Gore and Associates) was advanced over the wire to right PA. Valve size was confirmed with a 26-mm True Balloon (Becton, Dickinson and Company). A 26-mm Sapien S3 ULTRA valve (Edwards Lifesciences) was advanced, positioned at the ring, and deployed. Paravalvular leak at the site of dehiscence was then approached via an 8.5-F Agilist NxT steerable guide catheter (Abbott Vascular) and closed with a 27-mm Gore ASD occluder (W.L. Gore and Associates). The number, shape, and size of paravalvular defects can affect adequate defect sealing and prosthetic stability, affecting the overall efficacy and safety of transcatheter approaches. Transcatheter implantation of a transcatheter heart valve and atrial septal defect occluder can be used to treat high-risk patients with dehisced tricuspid rings complicated by intravalvular and paravalvular regurgitation.

28 March 2026 in JACC: Case Reports
Verified
Journal Article
Open access
AWAlan Wong
Alan Wong
JMJanelle Muuse
Janelle Muuse
AAAreen Al-Taie
Areen Al-Taie
NHNadia El Hangouche
Nadia El Hangouche
RBRichard Bae
Richard Bae
SGSantiago Garcia
Santiago Garcia
To describe a transcatheter mitral valve replacement case complicated by valve embolization into the left ventricle (LV) retrieved with the ŌNŌ (ŌNŌCOR LLC) retrieval basket via a transapical approach. Maintain wire position. Cannulate for venous-arterial extracorporeal membrane oxygenation. Perform left lateral thoracotomy at the fifth intercostal space and LV apex access. Advance a 21-F Certitude sheath (Edwards Lifesciences) over Amplatz Extra Stiff Wire (Cook Medical). Advance a 12-F ŌNŌ retrieval system through the sheath. Use grasping device and forceps (Raptor) to secure the valve in the basket. Maintaining wire position is critical when a transcatheter mitral valve replacement valve has embolized to prevent movement and possible LV outflow tract obstruction. A transapical approach using the ŌNŌ retrieval basket is a less invasive alternative for embolized TMVR valve retrieval in high-risk patients.

7 October 2026 in JACC: Case Reports
Verified
Journal Article
Open access
AIAmrita Iyengar
Amrita Iyengar
AWAlan Wong
Alan Wong
JMJanelle Muuse
Janelle Muuse
AAAreen Al-Taie
Areen Al-Taie
RGRaviteja R. Guddeti
Raviteja R. Guddeti
PSPuvi Seshiah
Puvi Seshiah