Mengzhen Wang

Mengzhen Wang

Auto-generated profile, based on publicly available information

Mengzhen Wang

Institute of Marine Science and Technology, Shandong University, Qingdao, Shandong, China

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 March 2025 in Measurement
Verified
Journal Article
Closed access
XBXiaoxue Bai
Xiaoxue Bai
XWXin Wang
Xin Wang
MZMuzi Zhang
Muzi Zhang
MWMengzhen Wang
Mengzhen Wang
BYBo Yang
Bo Yang
CWChi Wu
Chi Wu

12 March 2024 in Ocean Engineering
Verified
Journal Article
Closed access
XWXin Wang
Xin Wang
XBXiaoxue Bai
Xiaoxue Bai
MZMuzi Zhang
Muzi Zhang
MWMengzhen Wang
Mengzhen Wang
BYBo Yang
Bo Yang
Chi WuChi Wu
Chi Wu

4 November 2024 in IEEE Sensors Journal
Verified
Journal Article
Closed access
XBXiaoxue Bai
Xiaoxue Bai
XWXin Wang
Xin Wang
MZMuzi Zhang
Muzi Zhang
SZShanshan Zhao
Shanshan Zhao
MWMengzhen Wang
Mengzhen Wang
Chi WuChi Wu
Chi Wu
A novel seawater density sensor has been developed, offering high resolution and improved accuracy. The sensor employs a Michelson interferometer as the core sensing element, measuring density by directly incorporating seawater samples into the measurement path. To enhance measurement precision, standard seawater is used in the reference path to mitigate temperature and dispersion effects. The sensor system consists of a superluminescent diode and an interrogator, forming a compact, high-sampling-rate wavelength demodulation system that is particularly suitable for measuring seawater density with high spatiotemporal variability. However, the spectrum collected by the interrogator suffers from discontinuity. To address this issue, we designed a high precision multi wavelength demodulation algorithm. This algorithm not only analyzes the movement of each resonance peak with a resolution of 0.0008 nm within a 70nm detection range, but also enables continuous tracking of specific resonance peaks via a dynamic adjustment mechanism. It overcomes the measurement range constraints typically faced by interference-based sensors, which are limited to a single free spectral range. Experimental validations demonstrate the sensor’s capability, achieving a density resolution of 1.79×10 -5 kg/m 3 and an extended measurement range exceeding 35 kg/m 3 . The sensor’s average relative error in density measurement is 0.0144%, highlighting its effectiveness and potential for advanced oceanographic research.