14 December 2016 in BioMed Research International
Purpose. To present a computer-assisted-design/computer-assisted-manufacturing (CAD/CAM) technique for the design, fabrication, and clinical application of custom-made synthetic scaffolds, for alveolar ridge augmentation. Methods. The CAD/CAM procedure consisted of (1) virtual planning/design of the custom-made scaffold; (2) milling of the scaffold into the exact size/shape from a preformed synthetic bone block; (3) reconstructive surgery. The main clinical/radiographic outcomes were vertical/horizontal bone gain, any biological complication, and implant survival. Results. Fifteen patients were selected who had been treated with a custom-made synthetic scaffold for ridge augmentation. The scaffolds closely matched the shape of the defects: this reduced the operation time and contributed to good healing. A few patients experienced biological complications, such as pain/swelling (2/15: 13.3%) and exposure of the scaffold (3/15: 20.0%); one of these had infection and complete graft loss. In all other patients, 8 months after reconstruction, a well-integrated newly formed bone was clinically available, and the radiographic evaluation revealed a mean vertical and horizontal bone gain of mm and mm, respectively. Fourteen implants were placed and restored with single crowns. The implant survival rate was 100%. Conclusions. Although positive outcomes have been found with custom-made synthetic scaffolds in alveolar ridge augmentation, further studies are needed to validate this technique.
14 December 2014 in International Journal of Dentistry
Purpose. Nowadays, the advancements in direct metal laser sintering (DMLS) technology allow the fabrication of titanium dental implants. The aim of this study was to evaluate implant survival, complications, and peri-implant marginal bone loss of DMLS implants used to support bar-retained maxillary overdentures.Materials and Methods. Over a 2-year period, 120 implants were placed in the maxilla of 30 patients (18 males, 12 females) to support bar-retained maxillary overdentures (ODs). Each OD was supported by 4 implants splinted by a rigid cobalt-chrome bar. At each annual follow-up session, clinical and radiographic parameters were assessed. The outcome measures were implant failure, biological and prosthetic complications, and peri-implant marginal bone loss (distance between the implant shoulder and the first visible bone-to-implant contact, DIB).Results. The 3-year implant survival rate was 97.4% (implant-based) and 92.9% (patient-based). Three implants failed. The incidence of biological complication was 3.5% (implant-based) and 7.1% (patient-based). The incidence of prosthetic complication was 17.8% (patient-based). No detrimental effects on marginal bone level were evidenced.Conclusions. The use of 4 DMLS titanium implants to support bar-retained maxillary ODs seems to represent a safe and successful procedure. Long-term clinical studies on a larger sample of patients are needed to confirm these results.
19 May 2016 in International Journal of Dentistry
Purpose. To evaluate the soft tissue stability around single implants inserted to replace maxillary lateral incisors, using an innovative 3D method.Methods. We have used reverse-engineering software for the superimposition of 3D surface models of the dentogingival structures, obtained from intraoral scans of the same patients taken at the delivery of the final crown (S1) and 2 years later (S2). The assessment of soft tissues changes was performed via calculation of the Euclidean surface distances between the 3D models, after the superimposition of S2 on S1; colour maps were used for quantification of changes.Results. Twenty patients (8 males, 12 females) were selected, 10 with a failing/nonrestorable lateral incisor (testgroup: immediate placement in postextraction socket) and 10 with a missing lateral incisor (controlgroup: conventional placement in healed ridge). Each patient received one immediately loaded implant (Anyridge®, Megagen, Gyeongbuk, South Korea). The superimposition of the 3D surface models taken at different times (S2 over S1) revealed a mean (±SD) reduction of 0.057 mm (±0.025) and 0.037 mm (±0.020) fortestandcontrolpatients, respectively. This difference was not statistically significant (p= 0.069).Conclusions. The superimposition of the 3D surface models revealed an excellent peri-implant soft tissue stability in both groups of patients, with minimal changes registered along time.
26 November 2023 in Journal of Dentistry
1 January 2021 in International Journal of Periodontics & Restorative Dentistry
Giuseppe Luongo, MD, DDS/Massimo Simion, MD, DDS/Luca Ferrantino, DDS/Fabrizia Luongo, DDS, MS: This prospective longitudinal clinical trial aimed to evaluate the success of a bone-level implant with an integrated platform-switched connection by assessing peri-implant soft tissue and marginal bone level. Twenty-six patients were treated in two different centers with implants placed in healed partially edentulous ridges. Implant success rate and marginal bone level were evaluated with photographs, radiographs, and clinical measurements, with a 6-month postloading follow-up. The esthetic appearance of the photographed peri-implant soft tissue was evaluated at 6 months via the Pink Esthetic Score applied by two calibrated operators. All of the implants except for one placed in the mandible demonstrated successful osseointegration, resulting in a success rate of 97.8% at the 6-month follow-up. Compared to historical controls, no detectable differences in peri-implant marginal bone loss or esthetic outcome were seen.
11 March 2020 in Research Square
Background Digital technologies are becoming an irreplaceable assistance for a correct diagnosis and treatment planning of the dental therapy. Modern powerful software are able to match information coming from different sources (CBCT, IOS, lab and face scanners) creating a virtual patient where all the treatment options can be accurately tested. Guided surgery is based on the possibility to use these instruments to transfer the ideal plan directly into the operating theatre. However even in the hands of skilled operators there is always a difference between the position of the implant as determined on the virtual planning and the real position after the surgery. The aim of this multicenter prospective study is to test the advantages of the standardization of the digital workflow on the accuracy of the procedure. Methods 21 patients, for a total of 61 implants, have been treated in three different centers by operators with particular expertise in guided surgery. The accuracy of the procedure has been evaluated matching two files: the first from the pre-treatment virtual planning and the second from the optical impression taken immediately after the surgery. The digital workflow has been standardized using the same software for the planning, the same high quality manufacturing process, intraoral scanner and software for the overlapping procedure. Results All the implants showed an excellent primary stability. No intraoperative complications have been reported. The overlapping of the two files resulted in a mean angular deviation of 2.94°, a mean linear deviation at the platform of 0,73 mm and a mean vertical deviation at the apex of 0.01mm. Conclusions Almost the totality of the cases showed a better accuracy compared with the previous reported data of the literature. These results might be related with the standardization of the process so that following a precise protocol is mandatory for a safe use of this technique.