18 March 2024 in IEEE Transactions on Nuclear Science
Large area photomultiplier tube based on microchannel plate (MCP-PMT) is newly developed and applied in Jiangmen Underground Neutrino Observatory (JUNO). Large photocathode diameter is designed to improve the photocathode coverage rate of the main detector in JUNO, which certainly induces poor time resolution. In this paper, a new MCP-PMT with large photocathode and high time resolution is proposed. A novel conical focusing system with three separated electrodes is designed to generate the accelerating and focusing electric field. Three-dimensional models are developed in CST to validate its feasibility. Effects of the size and bias voltage of the focusing system and MCP are studied in detail using the finite integral technique and Monte Carlo method. Based on the simulation results, a set of geometry and operating parameters are chosen to obtain short transit time spread (TTS) and high collection efficiency (CE). Results show that CE of the new MCP-PMT is expected to be 94.0%. The mean TTS of photoelectrons from the whole photocathode achieves 1.68 ns.
6 September 2022 in IEEE Transactions on Nuclear Science
A 20-in. photomultiplier tube based on dynode and microchannel plates (Dynode-MCP-PMT) with high collection efficiency (CE) and good time performance is proposed in this article. To obtain a tailless time distribution, a pair of uncoated MCPs are employed. For a high CE, a dynode with two large openings is placed in front of the MCPs. The dynode is designed as a spherical shape to prevent secondaries from escaping the multiplication system and assist them moving to the MCPs for further multiplication. A 3-D model is developed by CST Studio Suite to validate its feasibility. Finite integral technique and Monte Carlo method are combined to simulate the photoelectron collection and multiplication processes. Results predict that for the shielded Dynode-MCP-PMT, CE is expected to be 100%. Tailless transit time distributions are observed. Transit time spread (TTS) of the photoelectrons from the cathode top point to the dynode achieves 3.7 ns. If this PMT is exposed to the geomagnetic field, it should be operated in the north and south direction, in which CE and TTS are expected to be 100% and 3.8 ns, respectively.
20 April 2026 in IEEE Transactions on Nuclear Science
Microchannel plate (MCP) is a widely used position-sensitive detector, and spatial resolution is a critical indicator for evaluating its performance. One well-known method for improving the spatial resolution is increasing the output electrode depth, but it significantly degrades the gain. In this paper, employing a material with low secondary electron yield (SEY) peak and high peak energy for the output electrode is proposed to enhance the spatial resolution while minimizing the adverse effect on gain. Effects of the electrode depth, material’s SEY peak and peak energy were comprehensively investigated using the finite integration technique and Monte Carlo method. The simulation results demonstrated that, at FWHM values of 76.45 μm (X) and 73.04 μm (Y), the gain achieved by our proposed method was approximately twice that obtained by increasing the electrode depth.
1 November 2026 in IEEE Transactions on Nuclear Science