21 December 2021 in IEEE Transactions on Instrumentation and Measurement
Nuclear magnetic resonance (NMR) relaxometry techniques have been widely used for evaluating hydrated cement paste as non-destructive and quantitative measurements. The important crystalline solid phases, such as Portlandite and Ettringite, are formed in the hydration of cement paste. However, it is challenging to quantify these crystalline solid phases by conventional NMR relaxation methods, due to their short-lived NMR signal lifetimes. A novel method for 2-D NMR $T_{1}$ – $T_{\mathrm {2S}}$ measurement of hydrated cement paste is proposed in this article. Combining a homebuilt NMR probe with short deadtime and high sensitivity, the $T_{1}$ – $T_{\mathrm {2S}}$ method can provide a more complete assessment of hydrogen-bearing crystalline solid phases (i.e., Portlandite and Ettringite) in hydrated cement paste. Experimental results demonstrated that the proposed method produced two additional distinct peaks in the $T_{1}$ – $T_{2}$ correlation map, compared with conventional methodologies. The attribution of the two peaks to Portlandite and Ettringite in hydrated cement paste was confirmed by heating experiments and partial least-square regression (PLSR) method. This technique has enabled detection and quantification of Portlandite and Ettringite in hydrated cement paste.
17 August 2022 in IEEE Transactions on Instrumentation and Measurement
The conventional Halbach permanent magnet usually has a high length-to-interdiameter ratio (LDIR) to gain a higher magnetic field homogeneity but can cause an increase in volume and weight, limiting the application in miniaturization. This article proposes a novel design and shimming method for the Halbach magnet to have not only a lower LDIR but also a better homogeneity. In this article, a multilayer magnetic ring structure was first designed through theoretical calculation and simulation optimization, which compensated for the magnetic field inhomogeneity. Then, a passive shimming method was applied which simulated the first-order and second-order terms of magnetic field inhomogeneity using small magnetic blocks whose magnetization direction was consistent with the main magnetic field. This method has high shimming efficiency and can avoid the demagnetization of the magnetic blocks caused by their magnetization directions against the direction of the main magnetic field, especially when the intensity of the magnetic field is close to or beyond the remanence of the magnetic blocks. The magnetic field intensity of the proposed magnet is 1.08 T and the homogeneity reaches close to the sub-ppm. The performance of the magnet was verified in the portable magnetic resonance imaging (MRI) system combined with a set of homemade low-power gradient coils. MRI images of phantoms and okra reached a resolution of 156 $\mu \text{m}$ [pixel size 156 $\mu \text{m}$ , matrix 128 $\times128$ , and field-of-view (FOV) $20\times20$ mm 2 ], which shows the potential for wide application of the proposed design and shimming method.
21 March 2025 in IEEE Transactions on Instrumentation and Measurement
Recently, there has been an impetus for developing low-field portable magnetic resonance imaging (MRI) technologies, driving a paradigm shift from conventional MRI scanners to point-of-care (POC) MRI scenarios. To facilitate the miniaturization of portable whole-body MRI, the weight of permanent magnet was reduced to 800 kg by shortening its axial depth, which allowed for the development of a 50 mT portable whole-body MRI prototype. The conventional MRI equipment usually uses Faraday shielded rooms to block electromagnetic interference (EMI) in complex environments, but it is difficult to apply in POC MRI scenarios. Furthermore, compared to the prevailing portable brain MRI scanner, the developed 50 mT short-axis portable whole-body MRI scanner is more susceptible to the EMI in open environments. To address this, a new active EMI rejection strategy featuring reduced hardware configuration and shorter model training time was proposed for unshielded portable whole-body MRI scanner. First, a multi-indicator evaluation method was designed to optimize the deployment of multiple EMI sensing coils. High-quality EMI sensing coils were selected, effectively reducing the hardware requirement by half. Then, the se-CNN model with three-layer convolutional neural network and SENet attention mechanism, was constructed to implement the EMI noise prediction and rejection. For model training, EMI noise data is acquired synchronously from multiple EMI sensing coils and the main MRI receive coil during the imaging data acquisition intervals, with a typical training time of about 2 minutes. The phantom and in-vivo imaging experiments demonstrated the improved image quality and validated the outperformance of the proposed EMI rejection strategy. This EMI rejection method has the potential to turbocharge the deployment of portable whole-body MRI scanners in clinical POC diagnosis and treatment.
19 April 2023 in IEEE Transactions on Instrumentation and Measurement
Fatty liver disease has become one of the common liver diseases seriously affecting people’s health and quality of life. Existing means to quantify liver fat content are usually invasive and high-cost. Our research aims to design a single-sided magnet to develop a low-cost, non-invasive, and lightweight unilateral magnetic resonance (UMR) system that can satisfy the needs for fatty liver screening and diagnosis. A novel single-sided permanent magnet with a pear-shaped magnetic field iso-surface was designed to avoid the excitation of subcutaneous tissue in the human body. The weight of the magnet was optimized to 12.9 kg, and the mean magnetic field strength of the region of interest (ROI) was 0.07 T. The radio frequency (RF) coil set, the pulse sequence, and the modeling method for measuring proton density fat fraction (PDFF) were also introduced. Experiments for phantoms and volunteers were carried out by the UMR system to verify the performance of detection. The phantom detection results show that the UMR system can effectively avoid the influence of the subcutaneous tissue part on PDFF detection, with reasonable accuracy (around 5% fat fraction error) and robustness (within 10% relative error). Compared with a conventional MRI scanner, measurement results of volunteers (around 3% fat fraction error) show the effectiveness of the UMR system for screening fatty liver diseases. The UMR system developed based on the proposed portable single-sided magnet could be a low-cost and reliable diagnostic tool for noninvasive fatty liver disease diagnosis.
27 January 2025 in IEEE Sensors Journal
Creating an effective gradient coil is essential for enabling portable, high-quality magnetic resonance imaging (MRI). This study introduces a method that incorporates a power consumption optimization function into spherical harmonic analysis to design an efficient gradient coil for a portable Halbach magnet with a low height-to-diameter ratio. The new design approach resulted in significant improvements over traditional methods, with the Y-direction gradient coil achieving an efficiency of 38.1 mT/m/A, reducing inductance and resistance by 43.09% and 24.77%, respectively. The Z-direction gradient coil also showed enhanced efficiency at 18.1 mT/m/A, a 45.97% improvement. Using this gradient coil design, a portable MRI device was constructed by integrating it with a homemade portable Halbach magnet, radio frequency probe, and electronic components from the laboratory. Imaging tests on a water phantom demonstrated the device’s ability to resolve small structures below 1 mm, achieving an image resolution of 62.5 μm × 62.5 μm. Overall, the gradient coil design method presented in this study successfully meets the requirements for portable, high-resolution MRI on-site.
22 December 2023 in IEEE Transactions on Instrumentation and Measurement
Multi-component imaging is considered to have the potential to access microstructure information, which is difficult to observe by common imaging methods in magnetic resonance imaging (MRI). Multi-component imaging methods are rarely studied in low-field MRI systems since the image data often has a low signal-to-noise ratio (SNR). Faced with MRI data with low SNR, previous methods will get broken component images and pseudo peaks in the spectrum of component distribution. This paper presents a multi-component imaging method suitable for MRI data with low SNR thus for low-field MRI systems. The proposed multi-component imaging method includes an optimized inversion method and a T 1 - T 2 MRI data acquisition method for a homebuilt 0.5 T MRI system with a permanent magnet. The optimized inversion method combines the intra-(zeroth-order regularization) and inter-voxel (spatial regularization) constraints in optimization problem formulation, aiming to increase the robustness of spectrum estimation for low-SNR MRI data. The corresponding solution algorithm for the optimization problem is also proposed. In the simulations and phantom MRI experiments, compared with other typical inversion methods, facing MRI data of low SNR (the SNR value of the highest-SNR image in MRI data was about 25), the optimized method shows a better convergence rate, smaller optimization error, and better stability features, especially avoiding the fragmentation of component images and the appearance of pseudo peaks in the spectrum. The proposed multi-component imaging method was also applied to natural plant samples. Results of plant samples show detailed features revealing inner water molecular states. This multi-component imaging approach can provide sub-voxel characterization and be applied to numerous applications of popular portable low-field MRI systems.