Cheng Peng

Cheng Peng

Auto-generated profile, based on publicly available information

Cheng Peng

Beijing Sport University

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 December 2023 in American Journal of Physical Medicine & Rehabilitation
Verified
Journal Article
Closed access
CPCheng Peng
Cheng Peng
DLDaxin Li
Daxin Li
TGTianxiao Guo
Tianxiao Guo
SLShuairan Li
Shuairan Li
YCYonghui Chen
Yonghui Chen
JMJing Mi
Jing Mi
Purpose: The aims of this study are to evaluate the effectiveness of different exercise interventions on patients with adolescent idiopathic scoliosis and to provide evidence-based exercise prescriptions for this population. Methods: The PubMed, Embase, Cochrane Library, Web of Science, CNKI, Chinese Biomedical Literature Database (CBM), VIP, and Wanfang Data Knowledge Service Platform were searched until January 2023. The data were pooled and a meta-analysis was conducted. Results: A total of 19 studies were conducted with 778 participants. The Schroth exercises group (mean difference = −3.48, 95% confidence interval = −4.73 to −2.23, P < 0.00001) and strength training group (mean difference = −3.43, 95% confidence interval = −4.06 to −2.80, P < 0.00001) had better recovery of the Cobb angle than the other groups. The Cobb angle rehabilitation effect was good in the time of less than 60-min group. In addition, there was no significant difference found between the different intervention periods groups (P > 0.05). Conclusions: Schroth exercise and strength training significantly improved Cobb angle of adolescent idiopathic scoliosis patients; exercising for less than 60 mins is effective for Cobb angle rehabilitation, but prolonging exercise time cannot improve training effectiveness; 12 wks of exercise significantly improved Cobb angle, but prolonged training periods did not have a significant impact.

7 August 2026 in International Journal of Sports Science & Coaching
Verified
Journal Article
Closed access
YWYanqi Wang
Yanqi Wang
CPCheng Peng
Cheng Peng
YHYaying He
Yaying He
RXRanxiao Xue
Ranxiao Xue
HZHongjun Zhang
Hongjun Zhang
JMJing Mi
Jing Mi
Objectives: This study aimed to compare the effects of plyometric training and traditional resistance training on upper-body sport-specific strength and stroke quality in adolescent table tennis athletes. Methods: Thirty-two adolescent athletes from the Liaoning Province Table Tennis Team were randomly assigned to either the Plyometric Training (PT) group (n = 16) or the Resistance Training (RT) group (n = 16) and underwent an 8-week training intervention. Upper-body sport-specific strength was assessed using the Standing Rotational Medicine Ball Throw, while the table tennis Hawk-Eye intelligent training system was used to measure indicators such as ball speed, spin rate, spin quality, and landing point control for the forehand backspin loop shot. Results: Significant interaction effects between time and group were observed for standing rotational medicine ball throw performance, ball speed, spin rate, and spin quality ( p < 0.05), indicating greater improvements in the PT group than in the RT group. No significant interaction effect between time and group was found for placement score ( p > 0.05). Conclusion: Compared with traditional resistance training, upper-body plyometric training was associated with greater improvements in upper-body sport-specific strength and forehand loop shot quality in adolescent table tennis athletes, particularly in ball speed, spin rate, and spin quality. However, these findings should be interpreted cautiously because biological maturation was not directly assessed.

9 September 2026 in Research Square
Verified
Preprint
Open access
PDF file
CPCheng Peng
Cheng Peng
XMXiao Ma
Xiao Ma
JMJing Mi
Jing Mi
Background Linear sprint testing is central to athlete monitoring, talent identification, return-to-play decisions, and research. In high-performance settings, however, practically meaningful changes in sprint time or maximal velocity can be small. Measurement error from timing and speed-measurement systems, start procedures, triggering events, sampling rates, and data processing can therefore be large enough to alter interpretation. Objectives This systematic review examined construct non-equivalence in sprint-test outcomes across timing and speed-measurement systems and protocols; mapped validity, agreement, reliability, sensitivity, and methodological error; and developed minimum reporting standards for future sprint-testing studies. Methods Records were searched in PubMed, Web of Science, SPORTDiscus via EBSCOhost, and IEEE. Eligible studies evaluated human linear sprint or running-speed tests using manual timing, fully automatic/photo-finish timing, optical timing gates, start-trigger systems, video or smartphone applications, radar or laser systems, GPS/GNSS/local positioning systems, inertial/wearable sensors, motorized sprint-resistance systems, or related approaches. Data were extracted at study, system-comparison, metric, and reporting-quality levels. Outcomes included accuracy, agreement, relative reliability, absolute reliability, sensitivity, methodological error, protocol features, and reporting completeness. Owing to heterogeneity in devices, reference standards, sprint tasks, triggering events, and statistical reporting, the synthesis was primarily narrative and evidence-map based. Results The search identified 1258 records. After duplicate removal, 648 records were screened. One hundred and fifty full-text reports were assessed, of which 131 were included in the evidence synthesis. Of these, 90 were core measurement-property studies and 41 were peripheral or methodological studies. The 131 included reports yielded 197 system-level comparisons. Evidence was concentrated in GPS/GNSS/local positioning systems (61 comparisons), timing gates/photocells (47), radar/laser systems (28), inertial or wearable systems (18), video/app/computer-vision methods (16), manual timing (10), other or multiple systems (10), and motorized or ergometer-based systems (7). Linear sprint splits and acceleration tasks dominated the literature (120 comparisons). However, similarly named outcomes were frequently generated from different start definitions, trigger events, body references, device geometries, sampling rates, filtering choices, and peak-speed definitions. Among applicable reports, reporting was strong for trial and score-selection rules, start distance or posture, device setup, device model, reference standard, and raw or summary results, but weaker for details needed to judge decision usefulness: limits of agreement (18%), smallest worthwhile change or minimum detectable change (22%), bias or mean difference (34%), 95% confidence intervals (42%), and single- versus dual-beam specification (42%). Metric-level evidence was most frequently assigned to agreement and absolute reliability domains, and reliability distributions showed generally high ICC values but more dispersed CV values, reinforcing the need to interpret relative reliability alongside absolute error and agreement. Conclusions Sprint-test outcomes are often construct-non-equivalent across systems and protocols; therefore, validity, agreement, reliability, sensitivity, and reporting standards must be interpreted together before sprint data can guide training or research decisions. No timing or speed-measurement system should be considered universally interchangeable. Manual timing, timing gates, radar/laser, GPS/GNSS, video, smartphone, inertial, and motorized systems can each be useful, but only when the measured event, body reference, acquisition settings, processing pipeline, and error statistics match the intended decision. Future studies should adopt minimum reporting standards that make sprint outcomes repeatable, interpretable, and not mistakenly compared across non-equivalent constructs.