Norbert Asprion

Norbert Asprion

Auto-generated profile, based on publicly available information

Norbert Asprion

BASF SE, Carl-Bosch-Straße 38, 67056 Ludwigshafen am Rhein, Germany

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2010 in Chemical Engineering and Processing - Process Intensification
Verified
Journal Article
Closed access
NANorbert Asprion
Norbert Asprion
GKGerd Kaibel
Gerd Kaibel

1 August 2001 in Fluid Phase Equilibria
Verified
Journal Article
Closed access
NAN. Asprion
N. Asprion
HHH. Hasse
H. Hasse
GMG. Maurer
G. Maurer

1 May 2018 in Computers & Chemical Engineering
Verified
Journal Article
Closed access
AMAlexander Mitsos
Alexander Mitsos
NANorbert Asprion
Norbert Asprion
CFChristodoulos A. Floudas
Christodoulos A. Floudas
MBMichael Bortz
Michael Bortz
MBMichael Baldea
Michael Baldea
PSPascal Schäfer
Pascal Schäfer

1 January 2014 in Computers & Chemical Engineering
Verified
Journal Article
Closed access
MBMichael Bortz
Michael Bortz
JBJ. Burger
J. Burger
NAN. Asprion
N. Asprion
SBS. Blagov
S. Blagov
RBR. Böttcher
R. Böttcher
HHH. Hasse
H. Hasse

1 February 2009 in Energy Procedia
Verified
Journal Article
Open access
HMHari Prasad Mangalapally
Hari Prasad Mangalapally
RNRalf Notz
Ralf Notz
SHSebastian Hoch
Sebastian Hoch
NANorbert Asprion
Norbert Asprion
GSGeorg Sieder
Georg Sieder
HHHans Hasse
Hans Hasse
The main challenge for the CO2 post combustion capture from power plant flue gases is the reduction of the energy requirement for solvent regeneration. The required reduction can only be achieved by application of new solvents. For the validation of new solvents in the absorption/desorption process, a pilot plant (column diameters 0.125 m, absorber packing height 4.2 m, flue gas flow 30–110 kg/h, CO2 partial pressure 35–135 mbar) was built in the EUproject CASTOR. To obtain a baseline for testing of new solvents, first systematic studies were carried out with MEA in that plant. All important process parameters, i.e. CO2 content in the flue gas, CO2 removal rate ΨCO2, fluid dynamic load, and solvent flow rate were varied. These studies allow detailed insight into the process, e.g., a quantification of the different contributions to the overall regeneration energy (namely: desorption enthalpy, stripping steam, heating up of solvent feed and condensate recycle) as a function of the chosen process parameters. A rate-based model of the process based on a detailed physico-chemical model was implemented in the process simulator CHEMASIM. It is shown that the model is able to predict the experimental results for MEA. Besides MEA, two new solvents were studied in the pilot plant. A direct comparison of different solvents in such pilot plant experiments is not trivial. The comparison of only a few operating points for the new solvents with seemingly corresponding results for MEA can lead to wrong conclusions, since for each solvent an optimisation of the operating conditions is necessary. Only systematical studies allow a meaningful comparison. The technique that was used in the present work for this purpose was measuring data sets at constant CO2 removal rate (by adjustment of the regeneration energy in the desorber) and systematically varying the solvent flow rate. A minimal energy requirement for the given removal rate is found from theses studies. Only the optima for different solvents should be compared. By this procedure, one solvent candidate was identified that shows an advantage compared to MEA

1 December 2009 in Fuel
Verified
Journal Article
Closed access
PCP. Galindo Cifre
P. Galindo Cifre
KBK. Brechtel
K. Brechtel
SHS. Hoch
S. Hoch
HGH. García
H. García
NAN. Asprion
N. Asprion
GSG. Scheffknecht
G. Scheffknecht