Mohammad Saber Azimi

Mohammad Saber Azimi

Auto-generated profile, based on publicly available information

Mohammad Saber Azimi

Óbuda University

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 November 2025 in European Journal of Nuclear Medicine and Molecular Imaging
Verified
Journal Article
Open access
PDF file
MAMohammad Saber Azimi
Mohammad Saber Azimi
ARArman Rahmim
Arman Rahmim
HAHossein Arabi
Hossein Arabi
ASAmirhossein Sanaat
Amirhossein Sanaat
NZNavid Zeraatkar
Navid Zeraatkar
Habib ZaidiHabib Zaidi
Habib Zaidi
Purpose: Partial volume effects (PVE) remain a major challenge in quantitative single-photon emission computed tomography (SPECT) and positron emission tomography (PET) imaging, often compromising both accuracy and reproducibility. While numerous Partial Volume Correction (PVC) methods have been proposed, their clinical translation is still limited. This review provides a clinically oriented evaluation of PVC methods with a particular focus on state-of-the-art applications in neurology, cardiovascular imaging, oncology, and radiopharmaceutical therapy dosimetry, highlighting where these techniques offer the greatest added value. In addition, we outline which PVC techniques have the potential to be used in clinical practice and which remain primarily suited for research purposes, along with their suitability in each of the above-mentioned clinical domains. Finally, this review addresses the central question of whether PVC is essential in clinical practice or whether its impact is context dependent. Methods: This review categorizes PVC approaches into three partially overlapping classes: reconstruction-based, post-reconstruction-based, and AI-driven or hybrid methods. Each class is further divided into anatomical and non-anatomical subcategories. We systematically compare their clinical applicability across key dimensions: quantitative accuracy, lesion detectability, robustness to noise and artifacts, anatomical dependence, generalizability across scanners and tracers, and clinical readiness. Results: PVC techniques often improve quantitative accuracy in small structures and in regions affected by spill-over from adjacent high-uptake tissues. However, these benefits can come at the cost of increased noise or edge artifacts, which may limit their robustness for routine clinical use. Post-reconstruction methods are sensitive to segmentation errors, while AI-driven models, despite their promise, require further validation using clinical benchmarks, comparison to ground truth, and testing on diverse datasets. Issues, such as generalizability and interpretability remain significant barriers. Conclusion: This review emphasizes the importance of application-tailored PVC protocols for reliable quantitative imaging in neurology, cardiology, oncology, and radiopharmaceutical therapy dosimetry. Not all PVC methods are beneficial; some may even impair interpretation in certain contexts. We provide a practical overview of which PVC approaches are most beneficial for each clinical scenario, aiming to guide both researchers and clinicians in selecting appropriate techniques for future studies and routine practice, and also outline key areas requiring further development for broader integration into research and clinical workflows. Graphical

1 March 2024 in Quantitative Imaging in Medicine and Surgery
Verified
Journal Article
Open access
PDF file
MAMohammad-Saber Azimi
Mohammad-Saber Azimi
AKAlireza Kamali-Asl
Alireza Kamali-Asl
MAMohammad-Reza Ay
Mohammad-Reza Ay
NZNavid Zeraatkar
Navid Zeraatkar
MHMahboubeh-Sadat Hosseini
Mahboubeh-Sadat Hosseini
HAHossein Arabi
Hossein Arabi
Background: Positron emission tomography (PET) imaging encounters the obstacle of partial volume effects, arising from its limited intrinsic resolution, giving rise to (I) considerable bias, particularly for structures comparable in size to the point spread function (PSF) of the system; and (II) blurred image edges and blending of textures along the borders. We set out to build a deep learning-based framework for predicting partial volume corrected full-dose (FD + PVC) images from either standard or low-dose (LD) PET images without requiring any anatomical data in order to provide a joint solution for partial volume correction and de-noise LD PET images. Methods: We trained a modified encoder-decoder U-Net network with standard of care or LD PET images as the input and FD + PVC images by six different PVC methods as the target. These six PVC approaches include geometric transfer matrix (GTM), multi-target correction (MTC), region-based voxel-wise correction (RBV), iterative Yang (IY), reblurred Van-Cittert (RVC), and Richardson-Lucy (RL). The proposed models were evaluated using standard criteria, such as peak signal-to-noise ratio (PSNR), root mean squared error (RMSE), structural similarity index (SSIM), relative bias, and absolute relative bias. Results: Different levels of error were observed for these partial volume correction methods, which were relatively smaller for GTM with a SSIM of 0.63 for LD and 0.29 for FD, IY with an SSIM of 0.63 for LD and 0.67 for FD, RBV with an SSIM of 0.57 for LD and 0.65 for FD, and RVC with an SSIM of 0.89 for LD and 0.94 for FD PVC approaches. However, large quantitative errors were observed for multi-target MTC with an RMSE of 2.71 for LD and 2.45 for FD and RL with an RMSE of 5 for LD and 3.27 for FD PVC approaches. Conclusions: We found that the proposed framework could effectively perform joint de-noising and partial volume correction for PET images with LD and FD input PET data (LD vs. FD). When no magnetic resonance imaging (MRI) images are available, the developed deep learning models could be used for partial volume correction on LD or standard PET-computed tomography (PET-CT) scans as an image quality enhancement technique.

23 July 2025 in NeuroImage
Verified
Journal Article
Open access
MAMohammad Saber Azimi
Mohammad Saber Azimi
MCMaryam Cheraghi
Maryam Cheraghi
FMFatemeh MahdiMaleki
Fatemeh MahdiMaleki
ASAmirhossein Sanaat
Amirhossein Sanaat
Poul Høilund-CarlsenPoul Høilund-Carlsen
Poul Høilund-Carlsen
Habib ZaidiHabib Zaidi
Habib Zaidi
This study aims to evaluate the reproducibility of radiomic features in brain positron emission tomography (PET) imaging across different brain regions and partial volume correction (PVC) methods, and to identify optimal feature classes and correction strategies for reliable clinical modeling. This study analyzed 76 hybrid brain PET/MR images. Radiomic features were extracted from 21 anatomically segmented brain regions under seven conditions: uncorrected PET and six PVC techniques, including reblurred Van Cittert (RVC), Richardson-Lucy (RL), region-based voxel-wise (RBV), iterative Yang (IY), multi-target correction (MTC), and parallel level set (PLS) methods. A total of 93 features spanning six radiomics classes-First Order, Gray Level Co-occurrence Matrix (GLCM), Gray Level Run Length Matrix (GLRLM), Gray Level Size Zone Matrix (GLSZM), Gray Level Dependence Matrix (GLDM), and Neighborhood Gray Tone Difference Matrix (NGTDM)-were extracted using the PyRadiomics library. Reproducibility was assessed using the intraclass correlation coefficient (ICC) and coefficient of variation (COV). RVC and RL showed the best reproducibility, with over 60% of features having COV < 25% and ICC ≥ 0.75. In contrast, MTC and PLS resulted in the highest variability. GLCM and GLDM features were the most stable, while first order and NGTDM were the most variable. Regions, such as the cerebellum and lingual gyrus had the highest ICC values (≥ 0.9), whereas the fusiform gyrus and brainstem showed poor reproducibility (ICC < 0.5). Radiomics reproducibility in brain PET imaging is highly dependent on both the PVC method and anatomical region. RVC and RL are recommended for reliable quantitative analysis, particularly when used with robust feature classes, such as GLCM and GLDM. These findings emphasize the importance of methodological standardization and anatomically informed region-of-interest selection in radiomics research and clinical applications.

8 July 2025 in Computers in Biology and Medicine
Verified
Journal Article
Open access
MAMohammad Saber Azimi
Mohammad Saber Azimi
VFVahid Felfelian
Vahid Felfelian
NZNavid Zeraatkar
Navid Zeraatkar
HDHabibollah Dadgar
Habibollah Dadgar
HAHossein Arabi
Hossein Arabi
Habib ZaidiHabib Zaidi
Habib Zaidi
Reducing radiation dose from PET imaging is essential to minimize cancer risks; however, it often leads to increased noise and degraded image quality, compromising diagnostic reliability. Recent advances in deep learning have shown promising results in addressing these limitations through effective denoising. However, existing networks trained on specific noise levels often fail to generalize across diverse acquisition conditions. Moreover, training multiple models for different noise levels is impractical due to data and computational constraints. This study aimed to develop a supervised Swin Transformer-based unified noise-aware (ST-UNN) network that handles diverse noise levels and reconstructs high-quality images in low-dose PET imaging. We present a Swin Transformer-based Noise-Aware Network (ST-UNN), which incorporates multiple sub-networks, each designed to address specific noise levels ranging from 1 % to 10 %. An adaptive weighting mechanism dynamically integrates the outputs of these sub-networks to achieve effective denoising. The model was trained and evaluated using PET/CT dataset encompassing the entire head and malignant lesions in the head and neck region. Performance was assessed using a combination of structural and statistical metrics, including the Structural Similarity Index (SSIM), Peak Signal-to-Noise Ratio (PSNR), Standardized Uptake Value (SUV) mean bias, SUVmax bias, and Root Mean Square Error (RMSE). This comprehensive evaluation ensured reliable results for both global and localized regions within PET images. The ST-UNN consistently outperformed conventional networks, particularly in ultra-low-dose scenarios. At 1 % count level, it achieved a PSNR of 34.77, RMSE of 0.05, and SSIM of 0.97, notably surpassing the baseline networks. It also achieved the lowest SUVmean bias (0.08) and RMSE lesion (0.12) at this level. Across all count levels, ST-UNN maintained high performance and low error, demonstrating strong generalization and diagnostic integrity. ST-UNN offers a scalable, transformer-based solution for low-dose PET imaging. By dynamically integrating sub-networks, it effectively addresses noise variability and provides superior image quality, thereby advancing the capabilities of low-dose and dynamic PET imaging.

25 April 2026 in Biomedical Signal Processing and Control
Verified
Journal Article
Open access
MAMohammad Saber Azimi
Mohammad Saber Azimi
FMFatemeh MahdiMaleki
Fatemeh MahdiMaleki
MCMaryam Cheraghi
Maryam Cheraghi
AAAbass Alavi
Abass Alavi
Habib ZaidiHabib Zaidi
Habib Zaidi

1 March 2026 in Computational and Structural Biotechnology Journal
Verified
Journal Article
Open access
MAMohammad Saber Azimi
Mohammad Saber Azimi
NKNicolas Karakatsanis
Nicolas Karakatsanis
HSHamid Sabet
Hamid Sabet
MRMagdalena Rafecas
Magdalena Rafecas
SNSadek Nehmeh
Sadek Nehmeh
Habib ZaidiHabib Zaidi
Habib Zaidi
Introduction: Digital twins (DTs) in nuclear medicine are data-synchronized, physics-based models that replicate positron emission tomography (PET) and single-photon emission computed tomography (SPECT) systems by linking validated simulations with scanner configuration and calibration inputs. Instrumentation DTs (iDTs) extend system modeling by enabling feedback-driven assessment of detector performance, collimation, electronics behavior, and acquisition conditions. This review summarizes recent developments in PET and SPECT iDTs and evaluates their roles in system optimization. Materials and Methods: A structured literature review was conducted, and applications were grouped into 6 domains: (a) calibration and performance optimization, (b) predictive maintenance and fault detection, (c) quantitative correction and protocol optimization, (d) dosimetry and reconstruction benchmarking, (e) synthetic data generation and artificial intelligence (AI) training, and (f) scanner design and geometry evaluation. Attention was given to implementations integrating established detector and system models into unified, data-linked workflows. Results: Evidence shows that iDTs support virtual calibration, protocol assessment, and algorithm benchmarking. They can simulate detector misalignment and probabilistic hardware failures, factors relevant for high-resolution and small-animal imaging. iDTs also enable exploration of geometry changes, dose-sensitivity trade-offs, and long axial field-of-view configurations. However, current approaches remain fragmented, depend on vendor-specific components, and provide limited telemetry integration. Validation still relies mainly on standard National Electrical Manufacturers Association and quality control procedures. Conclusion: Future progress will benefit from modular and standardized iDT frameworks incorporating hardware realism, reliability modeling, and hybrid AI–physics strategies. Fully developed iDTs can improve calibration stability, support adaptive protocol design, enable early detection of component degradation, guide dose optimization, and accelerate virtual prototyping of next-generation PET and SPECT systems.