Carlos Macias-Romero

Carlos Macias-Romero

Auto-generated profile, based on publicly available information

Carlos Macias-Romero

Laboratory of Fundamental Biophotonics, École Polytechnique Fédérale de Lausanne, Lausanne, Switzerland

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2016 in Science Advances
Verified
Journal Article
Open access
PDF file
YCYixing Chen
Yixing Chen
HOHalil I. Okur
Halil I. Okur
NGNikolaos Gomopoulos
Nikolaos Gomopoulos
CMCarlos Macias-Romero
Carlos Macias-Romero
PCPaul S. Cremer
Paul S. Cremer
SRSylvie Roke
Sylvie Roke
Ions induce changes in the H-bond network of water that extend by >20 nm, vary for H 2 O and D 2 O, and lead to surface tension anomalies.

25 August 2017 in Science
Verified
Journal Article
Closed access
PDF file
CMCarlos Macias-Romero
Carlos Macias-Romero
INIgor Nahalka
Igor Nahalka
HOHalil I. Okur
Halil I. Okur
SRSylvie Roke
Sylvie Roke
Imaging surfaces with water: The surfaces of real materials are often highly chemically heterogeneous, and the reported values of even simple properties such as surface acidity can vary widely in many cases. Macias-Romeroet al.developed a microscope that images surfaces on the basis of second-harmonic generation from the orientation of interfacial water (see the Perspective by Hunger and Parekh). They followed the deprotonation of silica along glass micropipettes by changing solution pH and found many regions where the surface acidity deviated strongly from the average for the entire micropipette.Science, this issue p.784; see also p.755

11 June 2012 in Optics Express
Verified
Journal Article
Closed access
PDF file
Nirmal MazumderNirmal Mazumder
Nirmal Mazumder
JQJianjun Qiu
Jianjun Qiu
Matthew R. ForemanMatthew R. Foreman
Matthew R. Foreman
CRCarlos Macías Romero
Carlos Macías Romero
CHChih-Wei Hu
Chih-Wei Hu
PTPeter Török
Peter Török
We developed a four-channel photon counting based Stokes-polarimeter for spatial characterization of polarization effects in second harmonic generation (SHG). We have implemented a calibration technique allowing quantitative measurement of polarization parameters, such as the degree of polarization (DOP), degree of linear polarization (DOLP), degree of circular polarization (DOCP), as well as anisotropy from the acquired Stokes parameters. The technique is used as contrast mechanism to characterize the polarization properties from two potassium dihydrogen phosphate (KDP) micro-crystals and collagen type-I in SHG microscopy.

8 January 2013 in Optics Express
Verified
Journal Article
Closed access
PDF file
NGNikolaos Gomopoulos
Nikolaos Gomopoulos
CLCornelis Lütgebaucks
Cornelis Lütgebaucks
QSQinchao Sun
Qinchao Sun
CMCarlos Macias-Romero
Carlos Macias-Romero
SRSylvie Roke
Sylvie Roke
We present a method to perform hyper Rayleigh scattering from aqueous solutions and second harmonic scattering measurements from unlabeled interfaces of liposomes and nanoparticles in dilute solutions. The water and interfacial response can be measured on a millisecond timescale, thus opening up the possibility to measure label-free time dependent transport processes in biological (membrane) systems.

8 December 2014 in Optics Express
Verified
Journal Article
Open access
PDF file
CMCarlos Macias-Romero
Carlos Macias-Romero
MDMarie E. P. Didier
Marie E. P. Didier
PJPascal Jourdain
Pascal Jourdain
PMPierre Marquet
Pierre Marquet
PMPierre Magistretti
Pierre Magistretti
SRSylvie Roke
Sylvie Roke
Second harmonic generation (SHG) is inherently sensitive to the absence of spatial centrosymmetry, which can render it intrinsically sensitive to interfacial processes, chemical changes and electrochemical responses. Here, we seek to improve the imaging throughput of SHG microscopy by using a wide-field imaging scheme in combination with a medium-range repetition rate amplified near infrared femtosecond laser source and gated detection. The imaging throughput of this configuration is tested by measuring the optical image contrast for different image acquisition times of BaTiO3 nanoparticles in two different wide-field setups and one commercial point-scanning configuration. We find that the second harmonic imaging throughput is improved by 2-3 orders of magnitude compared to point-scan imaging. Capitalizing on this result, we perform low fluence imaging of (parts of) living mammalian neurons in culture.

11 March 2013 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
Nirmal MazumderNirmal Mazumder
Nirmal Mazumder
JQJianjun Qiu
Jianjun Qiu
Matthew R. ForemanMatthew R. Foreman
Matthew R. Foreman
CRCarlos Macías Romero
Carlos Macías Romero
PTPeter Török
Peter Török
FKFu-Jen Kao
Fu-Jen Kao
We report on the measurement and analysis of the polarization state of second harmonic signals generated by starch granules, using a four-channel photon counting based Stokes-polarimeter. Various polarization parameters, such as the degree of polarization (DOP), the degree of linear polarization (DOLP), the degree of circular polarization (DOCP), and anisotropy are extracted from the 2D second harmonic Stokes images of starch granules. The concentric shell structure of a starch granule forms a natural photonic crystal structure. By integration over all the solid angle, it will allow very similar SHG quantum efficiency regardless of the angle or the states of incident polarization. Given type I phase matching and the concentric shell structure of a starch granule, one can easily infer the polarization states of the input beam from the resulting SH micrograph.