19 January 2016 in Energy & Environmental Science
A novel series of lithium alkyl trimethyl borates and lithium aryl trimethyl borates have been prepared and investigated as cathode film forming additives. The borates are prepared via the reaction of lithium alkoxides or lithium phenoxides with trimethyl borate. Incorporation of 0.5–2.0% (wt) of the lithium borates to a baseline electrolyte (1.0 M LiPF6 in 3 : 7 (EC/EMC)) results in improved capacity retention and efficiency of high voltage graphite/LiNi0.5Mn1.5O4 cells especially upon cycling at elevated temperature (55 °C). The improved performance results from the sacrificial oxidation of the lithium borate on the cathode surface to generate a cathode passivation film. The lithium borates can be readily structurally modified to act as a functional group delivery agent to modify the cathode surface. Ex situ surface analysis of the electrodes after cycling confirms that the lithium borates modify the cathode surface and generate a borate rich surface film which inhibits electrolyte oxidation and Mn dissolution.
28 June 2016 in IEEE Transactions on Power Delivery
In this paper, a multiagent system-based protection and control scheme is proposed to deal with diverse operation conditions in distribution system due to distributed-generation (DG) integration. Based on cooperation between DG controller and relays, an adaptive protection and control algorithm is designed on converter-based wind turbine DG to limit the influence of infeed fault current. With the consideration of DG control modes, an adaptive relay setting strategy is developed to help protective relays adapt suitable settings to different operation conditions caused by the variations of system topology and DG status. The proposed scheme is tested and validated on a test distribution system in a hardware-in-the-loop real-time testing platform.
10 March 2020 in IEEE Transactions on Power Delivery
HVDC technologies are widely acknowledged as one of solutions for the interconnection of renewable energy resources with the main electric power grid. The application of the latest modular multi-level converter (MMC) makes power conversion much more efficient. Due to the relatively low impedance in a DC system, DC fault currents may rise to an extremely high level in a short period of time, which can be very dangerous for HVDC converters. To improve the sustainability and security of electricity transmission, protection solutions for HVDC systems are being developed. Nevertheless, they have various drawbacks on fault signal detection and timely clearance. This paper proposes a protection method that provides a fast and reliable solution addressing those drawbacks. A protection algorithm based on travelling wave simulation and analysis is proposed to detect abrupt transient signals. The algorithm shows high efficiency, reliability, selectivity and has low sampling frequency requirements. The proposed protection method has been validated through a cyber-physical simulation platform, developed using a real-time digital simulator (RTDS) and IEC 61850 communication links. The obtained results show that the proposed method has good potential for practical applications.
28 April 2022 in IEEE Transactions on Power Systems
To improve the frequency stability of power systems with a high penetration of converter-based generators, this paper proposes an Enhanced Frequency-Constrained Unit Commitment (E-FCUC) considering variable-droop-controlled Frequency Control (FC) from converter-based generators. Unlike previous studies emphasizing conventional and fix-droop converter-based generators participating in primary frequency response, the impact of converter-based generators with variable-droop FC schemes is investigated, modeled, and then incorporated into the UC problems. Firstly, the transfer function of variable-droop-controlled converter-based generators is modeled; then the available primary power reserves bounding provided by converter-based generators is derived. Secondly, the frequency dynamic of power systems considering joint frequency control from conventional generators and variable-droop-controlled converter-based generators is derived based on an analytical aggregated System Frequency Response (SFR) model. Since the nonlinear non-smooth nature of frequency dynamic function, the max-affine Piece Wise Linearization (PWL) method is used to fitting the dynamic frequency function. The fitting function is subsequently reformulated into mix-integer linearized constraints participating in UC studies. Case studies based on a modified IEEE 6 bus test system and a modified IEEE 118 bus test system are carried out to verify the effectiveness of the proposed E-FCUC through comparisons of results with existing empirical models.
15 December 2020 in IEEE Transactions on Smart Grid
Due to the increasing penetration of gas-fired units and power to gas facilities, the electrical power system and natural gas system are more and more bi-directionally coupled. To tackle the challenges on the optimal scheduling operation of an integrated gas and power systems (IGPS), this paper focuses on developing a novel approach to build a continuous spatial-temporal optimal operation schedule model. In the light of different time constants of the electrical power and natural gas systems, the continuous spatial-temporal optimal operation schedule model of IGPS is formulated in function space. Additionally, Bernstein polynomials are used to reformulate the continuous spatial-temporal optimization problem of IGPS to mixed-integer linear programming. In the study cases, the simulation results of a simple integrated system and a combined IEEE 39-bus power system and Belgian natural gas network demonstrate the accuracy and effectiveness of the proposed model.
14 November 2014 in IEEE Transactions on Power Delivery
In this paper, a multiagent system-based wide-area protection and control scheme is proposed to deal with the long-term voltage instability-induced cascading trips. Based on sensitivity analysis between the relay operation margin and power system state variables, an optimal emergency control strategy is defined to adjust the emergency states timely and prevent the unexpected relay trips. In order to supervise the control process and further minimize the load loss, an agent-based process control is adopted to monitor the states of distributed controllers and adjust the emergency control strategy. A hybrid simulation platform based on LabVIEW and real-time digital simulator is set up to simulate a blackout case in the power system of Eastern Denmark and to demonstrate the effectiveness of the proposed MAS-based protection strategy.