1 January 2022 in Colloids and Surfaces A: Physicochemical and Engineering Aspects
1 July 2021 in Colloids and Surfaces A: Physicochemical and Engineering Aspects
1 June 2022 in Review of Scientific Instruments
Some human exhaled volatile organic compounds (VOCs) can be employed to diagnose related human endogenous diseases as characteristic biomarkers, which is expected to be applied to rapid screening and grading because of their non-invasive and cost-effective advantages. In this study, we developed a compact gas chromatography (GC) platform mainly composed of an integrated silicon-based micro-column chip using micro-electromechanical system techniques and a miniaturized metal oxide semiconductor gas detector. In addition, the sampling/switching valve with related components and embedded microcontrollers was used for airflow control. The fabricated system selectively detected the five VOCs (pentane, acetone, toluene, octane, and decane) considered the typical endogenous disease biomarkers. In the experiments, the functional parameters of the system were investigated, and the optimum temperature conditions of the system for separation were determined. The results show that the system can successfully test the studied five VOCs as low as 1 ppm. In addition, the influence of interfering gas (carbon dioxide and ammonia) on the system for the VOC mixture is also investigated. Moreover, to prove the possibility of breath analysis of the fabricated system, the detection performance of isoprene and acetone at the ppb level is studied. Then, the concentration changes of the isoprene at the ppb concentration for human breath are successfully detected in the system. Therefore, we believe that the prepared compact GC system has potential applications in the human endogenous disease diagnosis for the VOC biomarkers.
8 February 2021 in Journal of Micromechanics and Microengineering
In this paper, the serpentine-shaped semi-packed chromatographic columns embedded with the micro-post array were developed to separate the characteristic markers of advanced fibrosis. The 3 m long micro separation columns with a rectangular channel cross-sectional dimension of 250 μ m × 200 μ m and the micropost diameter of 30 μ m were prepared by the micro-electromechanical system (MEMS) technology. Based on the static coating process, two kinds of microcolumns (Sp1 and Sp2) with different stationary phase coatings were prepared for comparison. In detail, the Sp1 column was only coated with polydimethylsiloxane (PDMS), and the Sp2 column was coated with PDMS functionalized by graphene oxide quantum dots (GOQDs). GOQDs is a carbon-based nanomaterial that had similar properties to graphene oxide (GO). Moreover, the microcolumns are connected to a conventional gas chromatograph for testing. Alkanes (C 5 –C 14 ) and benzene series (benzene, toluene, o-xylene, 1,3,5- trimethylbenzene) were used to evaluate the separation characteristics of microcolumns, and the effect of constant column temperature and heating rate on chromatographic performance was studied. The experimental results show that the potential characteristic markers of advanced fibrosis (pentane and benzene) could be effectively separated in alkanes and benzene series, respectively, and the separation effect of Sp2 was better than that of Sp1. In addition, the Sp2 column also showed good repeatability. Therefore, the GOQDs-functionalized PDMS coated column could assist the microdetector of the microsystem under development to rapidly, accurately and effectively distinguish the markers, and is expected to become a candidate for micro gas chromatography ( μ GC) column for micro-system integration.
11 July 2022 in Journal of Micromechanics and Microengineering
A serpentine-shaped semi-packed micro gas chromatography (GC) column with mesoporous inner surface and ionic liquid (IL) coating was developed for the separation of various typical volatile organic compounds in exhaled air. The mesoporous surface was prepared by coating silica nanoparticles on the inner surface of the micro GC column through static method and used as stationary phase support to improve the separation performance by its high surface area. The micro GC columns provide efficient separations for analytes including nonpolar (alkanes), weak polar (benzene series) and polar compounds (alcohols), as well as various typical markers of non-alcoholic fatty liver disease. The test results show that the resolution of most analytes is higher than 1.5, the elution peaks are symmetrical. Moreover, due to the chemical stability of IL, the micro GC had good repeatability, thermal stability and oxygen robustness. The maximum relative standard deviation of retention time was 0.44% in four weeks. During the programmed heating, a stable baseline was achieved and the baseline drift value was less than 4.8 mV when the operating temperature increased from 50 °C to 140 °C. The oxygen robustness was verified by a decrease of 7.2% in the peak capacity after exposure to dry air at 140 °C for 48 h. These characteristics showed the micro GC column is suitable for a portable breath analyzer.