Luke Turley

Luke Turley

Auto-generated profile, based on publicly available information

Luke Turley

Surgery, Royal College of Surgeons in Ireland, Dublin, IRL

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2023 in EFORT Open Reviews
Verified
Journal Article
Open access
PDF file
LTLuke Turley
Luke Turley
IBIan Barry
Ian Barry
ESEoin Sheehan
Eoin Sheehan
Background: Open tibial shaft fractures comprise almost 45% of all open fractures and are frequently the result of high-energy trauma. Due to contamination, limited soft tissue coverage of the tibial shaft and poor tibial blood supply, open tibial shaft fractures are associated with high rates of complication including malunion, non-union and infection. Intramedullary nailing (IMN) is a mainstay of treatment. This study aims to determine the frequency of the various complications in this cohort. Methods: A systematic review of papers published on Embase, PubMed and Cochrane databases pertaining to the use of IMN to fix open tibial shaft fractures were included. The available evidence was collated in regard to the incidence of union, malunion, non-union and infection seen in this cohort. Results: A total of 2767 citations were reviewed, and 17 studies comprising 1850 patients were included in the analysis. There was a delayed union rate of 22.4%, malunion rate of 8.3%, non-union rate of 9.7% and infection rate of 8.1% (95% CI: 5.7%–10.8%) in this patient cohort. Subgroup analysis showed a 3-fold increase in non-union and a 2-fold increase in deep infection among Gustilo III injuries compared to Gustilo I and II. Conclusions: IMN for open tibial shaft fractures results in high rates of union and low rates of infection, comparable to figures seen in closed injuries and superior to those seen with alternative methods of fixation. There is a substantially increased risk of complication associated with Gustilo III injuries, reinforcing the significance of the soft tissue injury in these patients.

18 November 2022 in Bone & Joint Open
Verified
Journal Article
Open access
RHRobert J. Hurley
Robert J. Hurley
FMFergus J. McCabe
Fergus J. McCabe
LTLuke Turley
Luke Turley
DMDanielle Maguire
Danielle Maguire
JLJulie Lucey
Julie Lucey
CHConor J. Hurson
Conor J. Hurson
Aims: The use of fluoroscopy in orthopaedic surgery creates risk of radiation exposure to surgeons. Appropriate personal protective equipment (PPE) can help mitigate this. The primary aim of this study was to assess if current radiation protection in orthopaedic trauma is safe. The secondary aims were to describe normative data of radiation exposure during common orthopaedic procedures, evaluate ways to improve any deficits in protection, and validate the use of electronic personal dosimeters (EPDs) in assessing radiation dose in orthopaedic surgery. Methods: Radiation exposure to surgeons during common orthopaedic trauma operations was prospectively assessed using EPDs and thermoluminescent dosimeters (TLDs). Normative data for each operation type were calculated and compared to recommended guidelines. Results: Current PPE appears to mitigate more than 90% of ionizing radiation in orthopaedic fluoroscopic procedures. There is a higher exposure to the inner thigh during seated procedures. EPDs provided results for individual procedures. Conclusion: PPE currently used by surgeons in orthopaedic trauma theatre adequately reduces radiation exposure to below recommended levels. Normative data per trauma case show specific anatomical areas of higher exposure, which may benefit from enhanced radiation protection. EPDs can be used to assess real-time radiation exposure in orthopaedic surgery. There may be a role in future medical wearables for orthopaedic surgeons. Cite this article: Bone Jt Open 2022;3(11):907–912.

4 May 2021 in Cureus
Verified
Journal Article
Open access
IBIan P. Barry
Ian P. Barry
LTLuke P. Turley
Luke P. Turley
DMDaniela L. Mwipatayi
Daniela L. Mwipatayi
ATAngel Thomas
Angel Thomas
MMMariah T. Mwipatayi
Mariah T. Mwipatayi
BMBibombe Patrice Mwipatayi
Bibombe Patrice Mwipatayi
Endovascular aneurysm repair (EVAR) has become the treatment modality of choice in patients with abdominal aortic aneurysms. This has resulted in endograft utilization within instructions for use (IFU) and in cases with proximal neck anatomy outside of IFU. To identify whether graft selection influences outcomes following EVAR outside of IFU. A retrospective analysis was conducted from previously published data for 636 patients, collated from the Endurant Stent Graft Natural Selection Global Post-Market Registry (ENGAGE) and the Global Registry for Endovascular Aortic Treatment (GREAT). Patients were recruited into the ENGAGE registry between 2009 and 2011 and into the GREAT registry between August 2010 and October 2016. In ENGAGE, they received the Medtronic Endurant stent graft (Medtronic Vascular Inc, Dublin, Ireland) for infrarenal AAA repair while patients analyzed in GREAT received the Gore Excluder stent-graft (W. L. Gore & Associates, Flagstaff, Arizona). Analyses were performed to evaluate all-cause mortality, aneurysm-related mortality, endoleak occurrence, and surgical reintervention rates between the two cohorts. Of the 636 patients, 225 were from ENGAGE (mean age 73 years) and 411 were from GREAT (mean age 75 years). 17.8% were treated outside of IFU in the ENGAGE registry, while 12.4% were treated outside IFU in the GREAT cohort. Five-year freedom from all-cause mortality was similar in both cohorts (65.6% vs. 63.8%). The rate of type IA endoleak development was lower in the Excluder cohort, although this may have been impacted by the fact that only endoleaks that underwent reintervention were recorded within GREAT analysis (Endurant 10.6% vs. Excluder 7.0%). The reintervention rate was 16% at five years following the Endurant aortic graft while it was 13.3% at five years with the Excluder. Treatment outside of IFU, be it with a suprarenal or an infrarenal fixation device, is associated with worse outcomes. This analysis reinforces the importance of the consideration of either fenestrated or open repair in those aneurysms that fail to satisfy IFU while endovascular repair in such a setting should be reserved as a last resort strategy.

20 January 2024 in Brain and Spine
Verified
Journal Article
Open access
JMJake M. McDonnell
Jake M. McDonnell
SYSalma Youssef
Salma Youssef
TRTayler Declan Ross
Tayler Declan Ross
HMHarry Marland
Harry Marland
LTLuke Turley
Luke Turley
JBJoseph S. Butler
Joseph S. Butler
Anterior cervical discectomy and fusion (ACDF) is commonly performed with cage and plate constructs to stabilise diseased or injured cervical segments. Despite it being a commonly performed procedure, there are notable rates of associated morbidity reported in the literature. Stand-alone spacers represent a novel form of instrumentation to conventional cage and plate constructs. Do stand-alone spacers have improved operative characteristics and postoperative outcomes in ACDF cohorts when compared to cage and plate constructs? A systematic review and meta-analysis was conducted of PubMed/Medline, Embase and Google Scholar databases per the Preferred Reporting Items for Systematic Reviews and Meta-Analyzes guidelines. Studies of interest included cage and plate instrumentation versus anchored stand-alone spacers for patients undergoing ACDF. Pre- and post-operative clinical and radiological outcomes were collated and compared for significance between cohorts. 10 RCTs were identified and included with 779 patients total. Mean age of the entire cohort was 50.1 years. 62% (483/779) of the cohort were male. 384 patients underwent ACDF with stand-alone cage, while 395 had ACDF with conventional cage and plate. Stand-alone spacers significantly outperformed conventional instrumentation in terms of estimated blood loss (p < 0.01), total postoperative complications (p < 0.01), dysphagia rates (p = 0.04) and adjacent segment disease (p = 0.04). Non-inferiority was evident in both patient reported outcome measures and radiological outcomes. This meta-analysis highlights the efficacy of stand-alone spacers for the management of primarily cervical spondylitic disease for both single-level and multi-level pathology, and thus presents an attractive alternative to conventional instrumentation for patients undergoing ACDF surgery.

4 January 2023 in Acta Orthopaedica et Traumatologica Turcica
Verified
Journal Article
Open access
LTLuke P. Turley
Luke P. Turley
EHEoghan T. Hurley
Eoghan T. Hurley
AWAilbhe White-Gibson
Ailbhe White-Gibson
KCKevin Clesham
Kevin Clesham
FLFrank Lyons
Frank Lyons
Objective: The purpose of the current study is to meta-analyze the randomized controlled trials in the literature comparing pronator quadratus repair versus no repair alongside volar plating of distal radius fractures. Methods: A search of the PUBMED/MEDLINE, EMBASE, and The Cochrane Library databases was performed. Any randomized con- trolled trials comparing pronator quadratus repair versus no repair alongside volar plating of distal radius fractures were included. The relevant information was collected by 2 blinded reviewers using a predetermined data sheet. Clinical outcomes were compared, with all statistical analyses performed using Review Manager Version 5.3. Results: Five randomized controlled trials with 273 patients were included. There was no significant difference in the range of motion in flexion-extension, ulnar-radial deviation, or pronation-supination. There was a significant difference in favor of the no repair group for Disabilities of the Arm, Shoulder and Hand (DASH) Score (MD [Mean Difference]: 2.63, P < .0001) and pronation strength (MD: 13, P < .0001). Furthermore, there was no significant difference in the visual analog scale score. There were 3 complications relating to pronator quadratus repair, in which patients developed carpal tunnel syndrome requiring a release. There was no significant difference in the re-operation rate. Conclusion: This study found that pronator quadratus repair when performing volar plating for distal radius fractures did not result in a significant improvement in functional outcome, range of motion, or strength. Level of Evidence: I, Systematic Review of Level 1 Studies, Level I, Therapeutic Study Cite this article as: Turley LP, Hurley ET, White-Gibson A, Clesham K, Lyons F. Pronator quadratus repair after volar plating for distal radius fractures: A systematic review and meta-analysis of randomized controlled trials. Acta Orthop Traumatol Turc., 2023;57(4):176-182.

20 April 2021 in Cureus
Verified
Journal Article
Open access
IBIan P. Barry
Ian P. Barry
LTLuke P. Turley
Luke P. Turley
ATAngel R. Thomas
Angel R. Thomas
MMMariah T. Mwipatayi
Mariah T. Mwipatayi
BMBibombe P. Mwipatayi
Bibombe P. Mwipatayi
Abdominal aortic aneurysms (AAA) are far more common in male than female gender, although they appear to have a more aggressive pathophysiology in females. Given the lower incidence of AAA in females, it has been difficult to assess the impact of graft selection for endovascular aortic aneurysm repair (EVAR) in this cohort. To identify whether graft selection influences outcomes following AAA endoluminal repair in female patients. A retrospective analysis of published data for 711 female patients was conducted, collating data from three cohorts - Endurant Stent Graft Natural Selection Global post-market registry (ENGAGE), Global Registry for Endovascular Aortic Treatment (GREAT) and U.S. Zenith multicenter trial in combination with the Zenith female registry. Patients were recruited into the ENGAGE registry between 2009 and 2011, the GREAT registry between August 2010 and October 2016, and into the Zenith registry between 2000 and 2003. Patients from ENGAGE received the Medtronic Endurant stent graft for infrarenal AAA repair, patients analysed in GREAT received the Gore Excluder stent graft and the Zenith group received the Cook Zenith stent graft. Analyses were performed to evaluate all-cause mortality, aorta-related mortality, endoleak occurrence and surgical reintervention rates between the three cohorts. Of the 711 females, 133 were from ENGAGE (mean age 76 years), 538 were from GREAT (mean age 75 years) and 40 were from Zenith (mean age 74 years). The rates of co-morbidities between the three groups were broadly similar except for atherosclerotic disease which was more commonly observed in those treated with the GORE Excluder. The rate of endoleaks was lower when the Excluder stent was utilised as compared to the other two stents (Excluder 6.7% vs. Zenith 12.5% vs. Endurant 35.3%) even considering the limited follow-up of the Zenith group to two years as compared to five years for both ENGAGE and GREAT. All-cause mortality was similar in all three groups across the period examined while aorta-related mortality was uncommon. Reintervention rate was 15% at two years following the utilisation of the Zenith aortic graft while the rate of intervention at five years was broadly similar between ENGAGE and GREAT. The newer generation, lower profile aortic endografts appear to have provided a safe and successful tool in the management of AAA in female patients, despite more complex aortic anatomy with shorter infrarenal neck length and larger aortic neck angulation.