1 March 2009 in Journal of Glaucoma
To investigate the relationship between bleb morphology, recorded using the Indiana Bleb Appearance Grading Scale (IBAGS), and intraocular pressure (IOP) after phacotrabeculectomy. Two years postphacotrabeculectomy, a single observer compared bleb morphology to the IBAGS standard photographs in 76 eyes of 76 patients. In addition, the presence or absence of microcysts was recorded. IOP was also measured. On multivariate analysis increasing bleb height was associated with a low IOP (P=0.017). An increase in IBAGS height score by 1 U resulted in a reduction in IOP of 2.16 mm Hg (95% confidence interval=0.40-3.92 mm Hg). In this study, there was no association between vascularity, bleb extent or microcysts, and IOP. There were no cases of bleb leak in this series. Two years postphacotrabeculectomy increased bleb height, as measured by the IBAGS, was associated with a decrease in IOP, with a 1 point increase in IBAGS height score resulting in a decrease of 2.16 mm Hg. We found no association between bleb extent, vascularity, or the presence or absence of conjunctival microcysts. As there were no cases of bleb leak in this study this characteristic could not be evaluated.
1 February 1995 in Ophthalmology
1 April 2010 in Journal of Glaucoma
Late onset trabeculectomy bleb leaks often require surgical repair to avoid hypotony and/or infection. Repair using local conjunctiva is typically performed. However, in cases in which local conjunctiva is limited and/or has failed, buccal mucous membrane can be used as a conjunctival substitute. Four cases of buccal mucous membrane repair for leaking trabeculectomy blebs are reported. Surgical technique is described. In each case of bleb leak, multiple nonincisional techniques failed to control the leak. In 3 of 4 cases, earlier reconstruction attempts with conjunctival advancement and/or free flaps failed. Each was ultimately repaired with buccal membrane autograft. One case required additional minimally invasive procedures to control postoperative leaking. One case required a second adjacent buccal graft for leaking residual conjunctival bleb. Each graft was functioning well at most recent follow-up ranging from 1 to 17 months. Buccal membrane is an abundant and effective conjunctival substitute for the repair of recalcitrant leaking trabeculectomy blebs. It may be useful in cases in which earlier conjunctival-based repairs have failed.
1 January 2015 in Journal of Glaucoma
To determine the pressure required to prime an Ahmed Glaucoma Valve (AGV) and determine whether the valve can be damaged by "over-priming pressure." Three AGVs, a syringe pump, and a manometer were used to assess priming pressure. Balanced salt solution was pumped through the AGV tube at increasing pressures until a jet of fluid was seen to eject from the AGV, as per manufacturer instructions. This was repeated 3 times for 3 different virgin AGVs giving the "priming pressure." A second experiment used the same experimental set up to determine the "over-priming pressure" on 3 other AGVs. Fluid was pumped through the AGV at increasing pressures until evidence of damage was seen. The valve function was assessed before and after the "over-priming" stress test. Valve function was determined by the closing pressure, which is the pressure at which the valve closes and fluid was no longer seen passing through the valve. The priming pressure in the 3 AGVs was 2844, 3154, and 3051 mm Hg (mean, 3017±158 mm Hg). The maximum pressure generated using the syringe pump was 10,860, 10,343, and 10,860 mm Hg (mean, 10,688±299 mm Hg). No damage was observed in the valve mechanism. AGV closing pressure before the "over-priming" stress test was 8, 6, and 13 mm Hg and after the stress test was 6, 7, and 13 mm Hg. This study demonstrates that the priming pressure is consistent at around 3000 mm Hg. In addition, over-priming is not likely to damage or disturb the closing pressure.
1 December 2021 in Canadian Journal of Ophthalmology
1 December 2011 in Canadian Journal of Ophthalmology