Maria Helena Rossy Borges

Maria Helena Rossy Borges

Auto-generated profile, based on publicly available information

Maria Helena Rossy Borges

Universidade Estadual de Campinas, Brazil

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2020 in Brazilian Journal of Oral Sciences
Verified
Journal Article
Open access
PDF file
MBMaria Helena Rossy Borges
Maria Helena Rossy Borges
CDCarmen Gilda Tavares Dias
Carmen Gilda Tavares Dias
CACristiane de Melo Alencar
Cristiane de Melo Alencar
CSCecy Martins SILVA
Cecy Martins SILVA
RERenata Antunes Esteves
Renata Antunes Esteves
Aim: The purpose of this study was to compare the microhardness, diametral tensile strength, compressive strength and the rheological properties of self-adhesive versus conventional resin cements. Methods: Specimens of a conventional (RelyX ARC) and 3 self-adhesive (RelyX U200, Maxcem Elite, Bifix SE) types of resin cements were prepared. The Knoop test was used to assess the microhardness, using a Microhardness Tester FM 700. For the diametral tensile strength test, a tensile strength was applied at a speed of 0.6 mm/minute. A universal testing machine was used for the analysis of compressive strength and a thermo-controlled oscillating rheometer was used for the Rheology test. One-way ANOVA and Tukey’s test (α=0.05) were used for data analysis. Results: According to microhardness analysis, all the cements were statistically similar (p>0.05), except for Maxcem that presented lower hardness compared with the other cements in relation to the top surface (p0.05), presented higher value when compared to the Maxcem and Bifix cements (p<0.05). The compressive strength of RelyX ARC and Maxcem Elite cements was statistically higher than RelyX U200 and Bifix cements (p<0.05). Regarding the rheology test, Maxcem Elite and RelyX ARC cements showed a high modulus of elasticity. Conclusions: The self-adhesive cements presented poorer mechanical properties than conventional resin cement. Chemical structure and types of monomers employed interfere directly in the mechanical properties of resin cements.

1 January 2025 in Brazilian Oral Research
Verified
Journal Article
Open access
PDF file
MBMaria Helena Rossy Borges
Maria Helena Rossy Borges
LMLuís Fernando Bandeira Miranda
Luís Fernando Bandeira Miranda
SMSamuel Santana Malheiros
Samuel Santana Malheiros
ASAyrton Geroncio Silva
Ayrton Geroncio Silva
JNJoão Vicente Calazans Neto
João Vicente Calazans Neto
BNBruna Egumi Nagay
Bruna Egumi Nagay
This in vitro study evaluated the effects of citric acid (CA) on surface properties, biofilm removal, and electrochemical performance of Co-Cr alloys compared to common denture cleansers. Co-Cr discs were divided into five groups based on the decontamination solution: NaCl 0.9% (control), Corega Tabs®, Periogard®, and 10% CA. The surface was characterized at baseline in terms of morphology, topography, and chemical and phase composition. Surface properties, including microhardness, wettability, and roughness, were assessed before and after exposure to each solution. Microbial viability, metabolic activity, and morphology of the polymicrobial biofilm were assessed after treatment to evaluate the efficacy of the decontamination solutions. Electrochemical and morphological evaluations were performed to assess the impact of each solution on the alloy’s corrosion process. No significant changes in microhardness were observed (p > 0.05). Decontamination solutions significantly increased surface hydrophilicity (p < 0.05) and roughness, though Ra values remained below the threshold for bacterial colonization. All denture cleansers significantly reduced biofilm viability compared to NaCl (p < 0.05), with no viable colonies post-treatment. The CA group showed a significant reduction in bacterial metabolic activity compared to NaCl and Periogard® (p < 0.05), indicating superior biofilm disruption. Electrochemical tests demonstrated that CA maintained a stable Cr-oxide passive layer, evidenced by nobler OCP values and lower icorr and corrosion rates compared to Periogard® (p < 0.05). SEM images revealed pitting corrosion in all groups, except CA. These findings suggest that CA is a promising and safer alternative for denture care, offering effective antimicrobial action while preserving the electrochemical integrity of Co-Cr alloys.

24 October 2025 in Brazilian Journal of Oral Sciences
Verified
Journal Article
Open access
PDF file
JNJoão Vicente Calazans Neto
João Vicente Calazans Neto
CCCícero Andrade Sigilião Celles
Cícero Andrade Sigilião Celles
MBMaria Helena Rossy Borges
Maria Helena Rossy Borges
SMSamuel Santana Malheiros
Samuel Santana Malheiros
GBGuilherme Almeida Borges
Guilherme Almeida Borges
BNBruna Egumi Nagay
Bruna Egumi Nagay
Aim: The choice between retention systems in implant-supported prostheses impacts marginal bone loss (MBL), a key factor for implant longevity. Due to variability in the findings of systematic reviews, this overview aims to assess the methodological quality and synthesize available evidence from systematic reviews on the effects of cement- versus screw-retained implant-supported prostheses on MBL. Methods: Six databases were searched for systematic reviews comparing MBL in screw- versus cementretained implant-supported prostheses. The methodological quality was assessed using AMSTAR 2, and the MBL effects were classified as favoring cemented, no difference, or favoring screwed systems based on the conclusions of the reviews. Additionally, quantitative data on MBL at different intervals—up to 1, 3, 4, and more than 4 years—were extracted from primary articles and visually plotted for interpretation. Results: The search identified 8 systematic reviews, mainly classified as critically low quality, which found no significant difference in MBL between retention systems. Evaluating the quantitative data, both systems exhibited minor variations over time, with cemented implant-supported prostheses showing slightly less bone loss at the five-year follow-up. Beyond 4 years, both systems demonstrated similar MBL ranges. Conclusion: Both screw-retained and cement-retained implant-supported prostheses appear to be reliable options, with no significant difference in MBL observed in most systematic reviews, especially over longer follow-up periods. However, due to the low quality of existing systematic reviews, conclusions should be approached with caution, underscoring the need for betterdesigned studies to reach a clearer clinical consensus.

18 December 2025 in ACS Omega
Verified
Journal Article
Open access
SCStéfany Barbosa Alves da Cruz
Stéfany Barbosa Alves da Cruz
RCRaphael Cavalcante Costa
Raphael Cavalcante Costa
FFFrancieli da Silva Flores
Francieli da Silva Flores
MBMaria Helena R. Borges
Maria Helena R. Borges
DMDoris Hissako Matsushita
Doris Hissako Matsushita
LFLeonardo Faverani
Leonardo Faverani
Diabetes mellitus is a globally prevalent metabolic disorder that impairs wound healing and bone regeneration, compromising outcomes in implant therapies that rely on osseointegration. Advances in precision medicine and bioengineering have driven the development of functionalized implant surfaces to overcome these limitations. Among them, bioactive glass (BG) coatings have emerged as promising candidates to enhance biological responses. Building upon this rationale, we unveiled the osteoinductive potential of a BG-based coating synthesized via plasma electrolytic oxidation (PEO) and its effects on peri-implant bone regeneration in a diabetic rat model. Titanium implants were treated with PEO using a formulation mimicking BG composition (∼45.0 Si, 24.5 Ca, 24.5 Na, 6.0 P; m/v %), and the resulting coating was characterized. Implants with a sandblasted and acid-etched (SLA) surface served as the control. In vivo evaluation was conducted in Wistar rats with streptozotocin-induced diabetes mellitus, followed by tibial implant placement. At 14 and 28 days postimplantation, samples were harvested for histological, immunohistochemical, micro-CT, and histomorphometric analyses. Physicochemical characterization confirmed the synthesis of the PEO-BG coating, which exhibited enhanced surface roughness and wettability compared to SLA controls. A significantly greater area of newly formed bone, increased bone–implant contact, and favorable bone turnover were noted in the PEO-BG group. The expression profiles of BMP-2, RANKL, OPG, and OCN indicated modulation of osteogenic and inflammatory pathways consistent with accelerated bone repair. These findings demonstrate that PEO-BG coating confers robust osteoinductive potential, enhancing peri-implant bone regeneration under compromised diabetic conditions, and highlight its potential for translational application in high-risk populations.

1 January 2024 in Brazilian Dental Journal
Verified
Journal Article
Open access
PDF file
VAVictoria L Abdo
Victoria L Abdo
CDCaroline Dini
Caroline Dini
MBMaria Helena R Borges
Maria Helena R Borges
DDDanilo V A P Domingues
Danilo V A P Domingues
KSKamily A C C Sanchez
Kamily A C C Sanchez
JSJoao Gabriel Silva Souza
Joao Gabriel Silva Souza
Nonsurgical therapies have been recommended and employed as a less invasive and cost-effective modality in managing periodontitis. In this context, different therapeutic protocols have been tested in the last decades. Therefore, mapping the scientific trends and patterns provides critical insights into the state of research in the field, which has not been explored for overall nonsurgical periodontitis treatment studies. Articles from 2001 to 2020 were retrieved from the Web of Science database using appropriate terms and keywords. Article selection and data extraction were performed by calibrated examiners. All articles focusing on nonsurgical periodontitis treatment were included. Descriptive, bivariate, and multivariate logistic regression analyses were conducted. 1,519 articles were included. Randomized clinical trials (RCTs) were the most used design (44.1%), and professional biofilm control was the topic most studied (35.6%). Europe published the most significant number of articles (41.1%). The USA was the country that collaborated more with other countries. Asia (p<0.001), South America (p=0.004), and Oceania/Africa (p=0.016) showed a lower chance to have international collaboration. Studies from North America were more likely to be RCTs than studies from Europe (p=0.050); studies focusing on professional biofilm control (p<0.001) and other topics (p<0.001) were less likely to be evaluated by RCTs. The nonsurgical periodontitis treatment field mainly conducted RCTs, and the topic most explored by all studies was professional biofilm control. International collaboration and conduct of RCTs in this field occurred mainly among high-income countries. Decentralizing scientific resources, making integrative connections globally, and evaluating new topics may improve evidence-based periodontology.