19 May 2025 in Biomaterials
1 January 2022 in SSRN Electronic Journal
Fungal infections are a rapidly increasing public health problem due to their high morbidity and mortality rates, especially in populations with compromised immune systems. Rapid and accurate diagnosis of these diseases is, therefore, necessary to improve the prognosis of afflicted patients. Unfortunately, current clinical chemistry practice relies on lengthy culturing methods that are insufficient to meet the fast turnaround requirements. Here we present a cost-effective and robust nucleic acid sensor that can identify the presence of histoplasmosis causing fungal genes, in whole blood or Bronchoalveolar lavage (BAL) samples, far earlier than current methods. Our novel assay involves the hybridization of target gene sequences with immobilized nucleic acid probes, allowing direct, label-free detection of Hcp100, CBP1, and M antigen genes through electrochemical analysis. The resultant current is attributed to the presence of fungal targets in the sample solution. The assay provides ultra-sensitive detection of DNA molecules with a limit of detection (LOD) values down to 100 aM, sufficient to meet the clinical diagnostic need. In addition, the turnaround time for the sample to result is less than 90 minutes compared to the current clinical procedure’s turnaround time of 3-4 weeks.
1 January 2022 in SSRN Electronic Journal
Rapid and accurate diagnosis of fungal diseases is an urgent medical need. The public health impact of fungal infections is on the increase due to high morbidity and mortality, especially in immune-compromised patients. Unfortunately, current medical diagnostics outside of lengthy culturing methods are insufficient to meet clinical requirements. The overall goal of this study is to develop a cost-effective and robust nucleic acid sensor that can rapidly and accurately identify the presence of Histoplasma-specific fungal genes to yield an early and definitive diagnosis of histoplasmosis. Our assay involves the hybridization of target gene sequences with immobilized nucleic acid probes, allowing direct, label-free detection of target organisms using an electrochemical output signal. The resultant current is attributed to the presence of fungal target genes in the sample solution, specifically Hcp100 , CBP1 , or M antigen. The assay provides ultra-sensitive detection of DNA molecules with a limit of detection (LOD) values down to 100 attomolar (aM), sufficient to meet the clinical diagnostic need. In addition, the turnaround time for the sample to result is relatively fast (≤90 mins). We have successfully developed this electrochemical assay capable of rapid, highly specific, and sensitive detection of Histoplasma specific genes in whole blood and Bronchoalveolar lavage (BAL) samples.
29 July 2026 in SSRN Electronic Journal
Wastewater-based epidemiology (WBE) is an emerging tool for monitoring community-level opioid consumption, but widespread implementation remains limited by the need for ultra-trace detection in complex wastewater matrices. Many existing methods capable of parts-per-trillion (ppt) quantitation rely on high-end mass spectrometry platforms that are costly and technically demanding. Consequently, there remains a critical need for sensitive and scalable workflows that can be implemented using widely available LC-MS/MS instrumentation. Here, we present a highly sensitive and accessible HPLC-MS/MS method for opioid analysis using a SCIEX Triple Quad 3500, a mid-range triple quadrupole instrument. The method targets opioids and opioid metabolites relevant to WBE: morphine, morphine-3-glucuronide (M3G), morphine-6-glucuronide (M6G), norfentanyl, noroxycodone, methadone, and 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP). A key methodological innovation of this workflow is the integration of aqueous reconstitution with large-volume injection following SPE enrichment, enabling ppt-level quantitation on a mid-range triple quadrupole platform. Reconstitution in 100% water improved chromatographic peak shape and signal intensity for polar glucuronide metabolites while allowing a 10-fold increase in injection volume without compromising chromatographic performance. Scheduled multiple reaction monitoring (MRM) further enhanced selectivity and sensitivity for structurally similar analytes, such as M3G and M6G. The method was validated using wastewater samples from the Greater Albany, NY region, demonstrating robust performance in complex matrices. The results establish a scalable framework for ppt-level opioid surveillance using widely accessible LC-MS/MS instrumentation. Importantly, the method enables ppt-level quantitation of opioid glucuronides on a mid-range triple quadrupole platform without requiring high-resolution or premium-tier instrumentation, improving the accessibility of wastewater-based epidemiology workflows.