Kim Yan

Kim Yan

Auto-generated profile, based on publicly available information

Kim Yan

CUHK, T Stone Robotics Institute and the Department of Mechanical and Automation Engineering, Hong Kong, Hong Kong

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 July 2021 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
WZWenhui Zeng
Wenhui Zeng
JYJunyan Yan
Junyan Yan
KYKim Yan
Kim Yan
XHXu Huang
Xu Huang
XWXuefeng Wang
Xuefeng Wang
SCShing Shin Cheng
Shing Shin Cheng
A neurosurgical robot with 3-dimensional (3D) distal manipulation can increase instrument workspace for reaching peripheral regions of intracranial lesions to achieve complete lesion removal and minimal brain manipulation in a keyhole procedure. In this work, we designed a Nitinol-based symmetrically notched continuum robot based on the neurosurgical clinical constraints. A mechanics model is developed for the robot using a second order differential equation that exploits the shearing force formulation based upon the Euler $-$ Bernoulli moment-curvature equation. It affords non-constant curvature analysis, and integrates the piecewise linear material model with three stages that closely approximates the nonlinear superelastic property of Nitinol. A solution was introduced to this complex mechanics model based on the fourth order Runge-Kutta method with variable transformation, and an iterative approach. Comparison with the experimental data using our proposed model shows its high modeling accuracy in terms of the bending angle and tip position for a single symmetric notch bending as well as 2D bending motion of the robot. The significantly improved accuracy over previous models justifies the added complexity of our modeling approach and could better guide the determination of the notch parameters during robot design.

11 March 2022 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
JYJunyan Yan
Junyan Yan
JCJibiao Chen
Jibiao Chen
JCJunfan Chen
Junfan Chen
WYWanquan Yan
Wanquan Yan
QDQingpeng Ding
Qingpeng Ding
SCShing Shin Cheng
Shing Shin Cheng
Objective: This paper aims to investigate a new continuum robot design and its motion implementation methods appropriate for a minimally invasive intracerebral hemorrhage (ICH) evacuation. Methods: We propose a continuum robotic cannula, consisting of a precurved body and a 2-degree-of-freedom (DoF) flexible tip, monolithically fabricated. Kinematic model with cable elongation model, and a dedicated design optimization and motion planning algorithm were developed to enable the follow-the-leader (FTL) motion of the cannula. A task-dependent Jacobian-based closed loop control was also designed to track the cannula motion during the insertion and its independent tip motion. Results: Comprehensive experiments were conducted to verify the kinematic model and submillimeter motion coupling between the cannula precurved body and its flexible tip. The cannula was also capable of achieving FTL motion within around 2.5 mm shape deviation and control performance within submillimeter errors. It was finally demonstrated to be capable of the nonlinear insertion and tip manipulation in the brain phantom. Conclusion: The new cannula design, together with the proposed algorithms, provides the unique ability to access ICH in a nonlinear trajectory and dexterous tip motion. Significance: These motion capabilities of the robot in such a slender form factor will lead to more complete ICH evacuation and reduced trauma to the healthy brain tissues.

27 July 2022 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
QDQingpeng Ding
Qingpeng Ding
JCJianghua Chen
Jianghua Chen
WYWanquan Yan
Wanquan Yan
KYKim Yan
Kim Yan
AKAndre Kyme
Andre Kyme
SCShing Shin Cheng
Shing Shin Cheng
Shape memory alloy (SMA) has been adopted in medical robotics due to its high power density, compactness, and medical imager compatibility. However, its use in clinical applications remains limited due to its low actuation bandwidth and the lack of proper system integration approaches, leading to poor control accuracy and repeatability. In this article, we report the design, modeling, and characterization of a high-performance SMA actuator for real-time medical robotics application. It uses nichrome wire for fast heating and forced air convection for active cooling to improve the actuation bandwidth, with the SMA spring predisplacements tunable with a simple mechanism. All structures are packaged in a compact module to facilitate practical integration in a robotic system, and enable consistent performance and convenient use. We have also developed an intuitive constitutive model and heat transfer model of the actuator to facilitate selection of its critical parameters, such as SMA predisplacement, heating current, and air pressure, based on the performance requirements. During characterization, the actuator achieved a stroke of 147.2$\mathrm{^{\circ }}$, stall torque of 172.5 Nmm and actuation bandwidth of 0.43 Hz at $\pm$5$\mathrm{^{\circ }}$ rotation amplitude. It also demonstrated high control accuracy (error $< $1$\mathrm{^{\circ }}$) and high repeatability (standard deviation $< $0.16$\mathrm{^{\circ }}$) under closed-loop control. Torque–speed relationship was experimentally determined to show its performance under external loading. Finally, the actuator was used to build a steerable endoscope manipulator as a demonstration for real-time application in surgical robotics.

23 May 2023 in Medical Image Analysis
Verified
Journal Article
Closed access
WYWanquan Yan
Wanquan Yan
QDQingpeng Ding
Qingpeng Ding
JCJianghua Chen
Jianghua Chen
KYKim Yan
Kim Yan
Raymond TangRaymond Tang
Raymond Tang
SCShing Shin Cheng
Shing Shin Cheng

17 January 2020 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
SSShicong Shao
Shicong Shao
BSBotian Sun
Botian Sun
QDQingpeng Ding
Qingpeng Ding
WYWanquan Yan
Wanquan Yan
WZWenjia Zheng
Wenjia Zheng
SCShing Shin Cheng
Shing Shin Cheng
The paper presents a compact shape memory alloy (SMA)-actuated magnetic resonance imaging (MR)-conditional neurosurgical robotic system. It consists of a 2-degree of freedom (DoF) cable-driven steerable end effector, an antagonistic SMA springs-based actuation module, and a quick-connect module, packaged into a single integrated device measuring 305 mm length $\times 76$ mm diameter. The system is also highly adaptable, such that it could operate a cable-driven end effector up to a maximum of 4-DoFs and its length can be easily modified due to the acrylic plate-based modular construction. In addition to the kinematics of the robotic end effector and the SMA constitutive model, we also present the antagonistic SMA springs model under the known tension and cable displacement from the robotic end effector. We performed extensive characterization experiments to obtain SMA model parameters and integrated a feedforward component in our controller to achieve improved tracking of a sinusoidal reference up to 80° bending angle amplitude and 100s period. Lastly, proof-of-concept robot demonstrations were performed in a gel phantom and in the MRI that confirmed the robot motion capability in the brain and MRI compatibility of the robot.

1 February 2022 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
JCJianghua Chen
Jianghua Chen
QDQingpeng Ding
Qingpeng Ding
WYWanquan Yan
Wanquan Yan
KYKim Yan
Kim Yan
JCJibiao Chen
Jibiao Chen
SCShing Shin Cheng
Shing Shin Cheng
Transoral robotic surgery (TORS) in upper aerodigestive tract remains challenging due to the rigidity and insufficient workspace of existing instruments, and inappropriate balance between compliance and stiffness in flexible instruments. In this letter, a flexible surgical robotic instrument, featuring a shape memory alloy (SMA)-based continuously variable length bending joint (CVLBJ), was developed for TORS. The integration of the CVLBJ allows bending length adjustment, leading to enhanced distal workspace compared to traditional fixed length flexible instruments. The instrument also exhibits variable stiffness capability via the length variation of the CVLBJ and the SMA temperature variation. The quasi-static, kinematics, and stiffness model were developed to evaluate quantitatively the instrument workspace and stiffness range. The instrument was experimentally characterized and shown to provide a range of bending configurations suitable for the easily accessible oropharynx and the less accessible larynx, and stiffness range between 0.21 N/m and 1.83 N/m that is sufficiently large for tissue manipulation tasks. The instrument was also demonstrated to be capable of accurate motion tracking, given significant payload and 3D trajectory references. The proposed CVLBJ-integrated flexible instrument offers the variable length and variable stiffness properties missing in existing instruments that could potentially improve the clinical outcomes of TORS.