Photoacoustic (PA) imaging is a functional and molecular imaging technique capable of high sensitivity and spatiotemporal resolution at depth. Widespread use of PA imaging, however, is limited by currently available contrast agents, which either lack PA-signal-generation ability for deep imaging or their absorbance spectra overlap with hemoglobin, reducing sensitivity. Here we report on a PA contrast agent based on targeted liposomes loaded with J-aggregated indocyanine green (ICG) dye (i.e., PAtrace) that we synthesized, bioconjugated, and characterized to addresses these limitations. We then validated PAtrace in phantom, in vitro, and in vivo PA imaging environments for both spectral unmixing accuracy and targeting efficacy in a folate receptor alpha-positive ovarian cancer model. These study results show that PAtrace concurrently provides significantly improved contrast-agent quantification/sensitivity and SO2 estimation accuracy compared to monomeric ICG. PAtrace’s performance attributes and composition of FDA-approved components make it a promising agent for future clinical molecular PA imaging.
10 September 2018 in IEEE Transactions on Medical Imaging
As photoacoustic (PA) imaging makes its way into the clinic, accuracy of PA-based metrics becomes increasingly important. To address this need, a method combining finite-element-based local fluence correction (LFC) with signal-to-noise-ratio (SNR) regularization was developed and validated to accurately estimate oxygen saturation (SO2) in tissue. With data from a Vevo LAZR system, performance of our LFC approach was assessed in ex vivo blood targets (37.6% – 99.6% SO2) and in vivo rat arteries. Estimation error of absolute SO2 and change in SO2 reduced from 10.1% and 6.4%, respectively, without LFC to 2.8% and 2.0%, respectively, with LFC, while accuracy of the LFC method was correlated with the number of wavelengths acquired. This work demonstrates the need for SNR-regularized LFC to accurately quantify SO2 with PA imaging.
A variety of hematological diseases manifest in the bone marrow (BM), broadly characterized as BM failure (BMF). BMF can be caused by acute lymphoblastic leukemia (ALL), which results in an expansion of hypoxic regions in the BM. Because of this hypoxic presentation, there is potential for improved characterization of BMF through in vivo assessment of oxygenation in the BM cavity. Photoacoustic (PA) imaging can provide local assessment of intravascular oxygen saturation (SO2), which has been shown to correlate with pimonidazole-assessed hypoxia. This study introduces an optimized PA imaging technique to assess SO2 within the femoral BM cavity through disease progression in a murine model of ALL. Results show a statistically significant difference with temporal changes in SO2 (from baseline) between control and diseased cohorts, demonstrating the potential of PA imaging for noninvasive, label-free monitoring of BMF diseases.
Liposomal carriers, used for site-specific drug delivery, are being investigated for diagnostic approaches by replacing the therapeutic with an imaging contrast agent, exploring potential for selective treatment planning. There remains a critical need to improve in vivo assessment of biodistribution, stability, and clearance kinetics of liposomal carriers. This pilot study presents a multimodal approach in which liposome-encapsulated J-aggregated indocyanine green (ICG) dye (Lipo-JICG) is imaged with high spatial resolution using both in vivo photoacoustic (PA) imaging, to assess the absorbance characteristics of JICG and monomeric ICG, and ex vivo cryofluorescence tomography (CFT), to measure ICG fluorescence. An in vitro assay comparing the relationship between absorbance and fluorescence of Lipo-JICG and ICG demonstrated that the absorbance peak shifted from 780 to 895 nm as the Lipo-JICG:ICG ratio increased; meanwhile, the fluorescence decreased drastically as the Lipo-JICG:ICG ratio increased, demonstrating that J-aggregation quenches fluorescence. Twelve mice were then PA imaged pre-injection, then up to 6 days after Lipo-JICG injection. Unmixed Lipo-JICG signal peaked at 30 min post-injection in both liver and spleen; unmixed ICG signal peaked post-injection, decreasing over time in both organs and increasing at 6 days in the spleen. With CFT, ICG fluorescence followed a similar trend, with a maximum at 30 min in liver and at 6 days in spleen, implying that Lipo-JICG continued to break down and excrete through the hepatic system over 6 days post-injection. Future studies will continue to develop this methodology to assess biodistribution, stability, and clearance of liposomal carriers in tumor-bearing murine models.