Praveen Kumar Yadav Kundala

Praveen Kumar Yadav Kundala

Auto-generated profile, based on publicly available information

Praveen Kumar Yadav Kundala

Lendi Institute of Engineering and Technology

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2023 in International Journal of Electrical and Computer Engineering (IJECE)
Verified
Journal Article
Open access
PDF file
PKPraveen Kumar Yadav Kundala
Praveen Kumar Yadav Kundala
MMMrutyunjaya Mangaraj
Mrutyunjaya Mangaraj
Suresh Kumar SudabattulaSuresh Kumar Sudabattula
Suresh Kumar Sudabattula
In this research paper, an inductively coupled distributed static compensator (IC-DSTATCOM) for three phase three wire (3P3W) electric power distribution system (EPDS) is proposed. The contraction of power quality (PQ) was marked as a perilous droop mode bump into direct coupled distributed static compensator (DC-DSTATCOM). To regain the PQ, inductive coupling transformer is assisted in conjunction with DC-DSTATCOM. The system equivalent circuit of IC-DSTATCOM is accomplished by take into account of impedance of both transformer and DC-DSTATCOM to reveal the filtering technique. The filtering icos∅ mechanism is performed by following the generalized mathematical approach using MATLAB/Simulink. A case education is reviewed in detail to illustrate the performance of both DC-DSTATCOM and IC-DSTATCOM. The IC-DSTATCOM is amplified healthier as compared to other in terms of harmonics shortening, good power factor, load balancing, and potential regulation. To examine the effectiveness, simulation outputs of the IC-DSTATCOM with different PQ parameter indices are presented by following the benchmark measure of IEEE-2030-7-2017 and IEC-61000-1 system code.

1 December 2025 in International Journal of Advances in Applied Sciences
Verified
Journal Article
Open access
PDF file
VMVasupalli Manoj
Vasupalli Manoj
MSMalleti Sreedhar
Malleti Sreedhar
RSRebba Sasidhar
Rebba Sasidhar
PKPraveen Kumar Yadav Kundala
Praveen Kumar Yadav Kundala
DMDasyam Chandra Mouli
Dasyam Chandra Mouli
Ramana PillaRamana Pilla
Ramana Pilla
Electric bicycles (e-bikes) have rapidly emerged as a sustainable alternative to conventional modes of transportation. This study reviews the evolution, technological advancements, and environmental benefits of e-bikes through comparative data analysis, survey results, and case studies. The findings demonstrate that the developments in lithium-ion batteries, lightweight materials, and smart motor systems have significantly improved e-bike performance, efficiency, and affordability. From an environmental perspective, e-bikes can cut greenhouse gas emissions by more than 90% compared to cars, while simultaneously improving urban air quality and reducing overall pollution levels. Survey responses indicate that e-bike users often substitute short car trips, promoting sustainable commuting behaviors and supporting public health. Despite these benefits, challenges persist regarding insufficient infrastructure, inconsistent policy support, and limited battery recycling programs. In summary, e-bikes constitute a transformative element in sustainable urban mobility and climate change mitigation. Beyond policy reforms, future work should prioritize renewable-powered charging systems and circular battery utilization models to ensure e-bikes contribute to a more resilient and environmentally friendly transportation ecosystem.

25 July 2023 in International Journal of Applied Power Engineering (IJAPE)
Verified
Journal Article
Open access
PDF file
JSJogeswara Sabat
Jogeswara Sabat
MMMrutyunjaya Mangaraj
Mrutyunjaya Mangaraj
ABAjit Kumar Barisal
Ajit Kumar Barisal
PKPraveen Kumar Yadav Kundala
Praveen Kumar Yadav Kundala
RTRohan Vijay Thakur
Rohan Vijay Thakur
This article presents the dual operation of distributed energy resources (DER) integrated impedance source inverter (DI-ZSI). The distribution grid, DER and variable nonlinear load are operating on two modes. In mode-1, power generated by the DER is zero or less then the load requirement and the inverter act as a voltage source inverter (VSI) for shunt compensation only. But, in mode-2, power generated by the DER greater than the load requirement and operates as a DI-ZSI based distributed static compensator (DSTATCOM). In this scenario, it not only acts as a shunt compensator but also inject active power to the distribution grid. An accurately tuned proportional integral with adaptive least mean square (ALMS) controller is used to generate the switching signals of inverter switches. The DI-ZSI performs stable operation in the distribution grid over a variable non-linear loading. A field programmable gate array (FPGA) SPARTAN-6 controller is used to develop the proposed system. Experimental results from DI-ZSI and VSI under variable loading highlighted the superiority of the DI-ZSI as per guidelines imposed by IEEE-2030-7-2017.

6 September 2026 in Results in Engineering
Verified
Journal Article
Open access
MMMrutyunjaya Mangaraj
Mrutyunjaya Mangaraj
PKPraveen Kumar Yadav Kundala
Praveen Kumar Yadav Kundala
SSSuresh Kumar Sudabattula
Suresh Kumar Sudabattula
KSK. Subbaramaiah
K. Subbaramaiah

1 January 2026 in International Transactions on Electrical Energy Systems
Verified
Journal Article
Open access
PDF file
NKN. V. A. Ravi Kumar
N. V. A. Ravi Kumar
DMDasyam Chandra Mouli
Dasyam Chandra Mouli
MSMalleti Sreedhar
Malleti Sreedhar
PKPraveen Kumar Yadav Kundala
Praveen Kumar Yadav Kundala
VMVasupalli Manoj
Vasupalli Manoj
TKTheophilus A. T. Kambo
Theophilus A. T. Kambo
This study presents a safety‐aware conditional reinforcement learning (RL)–based supervisory proportional–integral (PI) gain scheduling scheme for robust load frequency control (LFC) of a three‐area interconnected power system. Different from most RL‐based LFC schemes that either replace the existing controllers or provide direct control action to actuators, the proposed scheme keeps the conventional PI controller as the only actuator‐driving unit and utilizes RL as a steady‐state supervisory gain tuner. A detailed nonlinear three‐area LFC model, which includes a full tie‐line coupling scheme, is considered. Multistep load disturbances are applied to one control area, and robustness is examined against simultaneous ±30% uncertainty in inertia, damping, governor, and turbine parameters. The proposed supervisory RL policy is implemented using an actor–critic RL algorithm, and the policy is activated only when both area control error (ACE) and its derivative are below a certain prespecified threshold. All gain changes are bounded and low‐pass filtered to ensure the nonintrusive nature of the controller. Simulation results, including single‐run and Monte Carlo analysis, demonstrate that the proposed controller retains the transient response and control effort characteristics of the particle swarm optimization (PSO)–tuned PI baseline while achieving an improved steady‐state frequency distribution with a lower spread under uncertainty. It is demonstrated that RL can provide useful benefits in LFC when it is used as a conditional steady‐state supervisory tool instead of a direct transient controller.

1 September 2026 in Engineering Research Express
Verified
Journal Article
Closed access
PDF file
MMMrutyunjaya Mangaraj
Mrutyunjaya Mangaraj
PKPraveen Kumar Yadav Kundala
Praveen Kumar Yadav Kundala
VMVenkateswaran Madhu
Venkateswaran Madhu
It is necessary to design, new varieties of voltage source inverter (VSI) structure to ensure the better power quality and maintain equilibrium between electrical distribution system (EDS) and consumer with economic pricing. As a main part of operation, deep belief learning network (DBLN) algorithm is implemented for switching ON/OFF the VSI. In order to build a high-accuracy evaluation model, a VSI based distribution static compensator (DSTATCOM) is considered as the reference model. Afterwards, the inductor & capacitor are successfully identified by mathematical analysis &incorporated in the EDS. Based on the input supply current harmonics reduction, power factor (PF) improvement in the input, potential regulation & constant DC potential capacitor of both structures, the evaluation outcomes are obtained. For a healthy three-phase three-wire (3P3W) EDS, these above essential performance indicators of the DSTATCOM are analyzed as per IEEE-519-2017 and EN-50160 standard. The overall EDS with DSTATCOM are designed using MATLAB/ Simulink. Simulation as well as experimental results using d-SPACE-1104 validated the effectiveness, accuracy, superiority & feasibility of the projected topology for the EDS.