Corrosion and scaling is a major problem in water distribution systems, thus evaluation of water corrosivity properties is a routine test in water networks. To evaluate water stability in the Bandar Abbas water distribution system, the network was divided into 15 clusters and 45 samples were taken. Langelier, Ryznar, Puckorius, Larson–Skold (LS) and Aggressive indices were determined and compared to the marble test. The mean parameters included were pH (7.8 ± 0.1), electrical conductivity (1,083.9 ± 108.7 μS/cm), total dissolved solids (595.7 ± 54.7 mg/L), Cl (203.5 ± 18.7 mg/L), SO4 (174.7 ± 16.0 mg/L), alkalinity (134.5 ± 9.7 mg/L), total hardness (156.5 ± 9.3 mg/L), HCO3 (137.4 ± 13.0 mg/L) and calcium hardness (71.8 ± 4.3 mg/L). According to the Ryznar, Puckorius and Aggressive Indices, all samples were stable; based on the Langelier Index, 73% of samples were slightly corrosive and the rest were scale forming; according to the LS index, all samples were corrosive. Marble test results showed tested water of all 15 clusters tended to scale formation. Water in Bandar Abbas is slightly scale forming. The most appropriate indices for the network conditions are the Aggressive, Puckorius and Ryznar indices that were consistent with the marble test.
1 August 2013 in American Journal of Applied Sciences
In this Research, oyster shell supported zero valent iron nanoparticles were prepared and applied for the removal of natural organic matters (NOMs) from aqueous solutions under different experimental conditions. The nanoadsorbents prepared by wet impregnation method, then characterized using Scanning Electron Microscopy, Energy Dispersive Spectroscopy, X-Ray Fluorescence and BET analysis. Adsorption test was done in a batch reactor and the effects of different parameters such as initial adsorbate concentration, adsorbent dose, adsorption kinetic, pH, and temperature on removal of NOMs (humic acid as the indicator) were studied. Results showed that particle size of nanoadsorbent was in the range of 60-83 nm, and surface area and micropore volume as 16.85 m2/g and 0.021 m3/g, respectively; the main elements of adsorbent were Ca, O, Fe and Na and lime, as high as about 94.25% was the main structural component of the total weight. Produced nanoadsorbent was not soluble in water. It was also shown that by increasing the nanoadsorbent dose from 0.5 to 5 g/100 ml, the removal of humic acid increased from 62.3% to 97.4%. An inverse relationship was found between initial concentration and adsorption capacity, so that a decreasing rate of 33% for humic acid removal was observed by increasing pH from 5 to 10. Temperature increase from 25°C to 40°C, resulted in an increase in humic acid removal from 76.8% to 91.4% and its adsorption on the adsorbent could be better described by Freundlich isotherm (n = 0.016, Kf = 0.013 and R2 = 0.74). The most fitted adsorption kinetic model was pseudo-second order model. The chemical structure of nanoadsorbent was proper and free from harmful substances. Despite the relative good condition of the effective surface, due to the large size of the shell, the overall micropore volume was low. Hence the qualitative characteristics the adsorbent caused the absorption capacity of humic acid to be low (0.96 mg/g).
1 February 2016 in Desalination and Water Treatment