Kevin Eatwell

Kevin Eatwell

Auto-generated profile, based on publicly available information

Kevin Eatwell

Royal (Dick) School of Veterinary Studies and Roslin Institute The University of Edinburgh Roslin UK

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 February 2013 in Journal of Small Animal Practice
Verified
Journal Article
Closed access
PDF file
KEK. Eatwell
K. Eatwell
EME. Mancinelli
E. Mancinelli
JHJ. Hedley
J. Hedley
EKEmma Keeble
Emma Keeble
MKM. Kovalik
M. Kovalik
DYD. A. Yool
D. A. Yool

15 March 2008 in Veterinary Record
Verified
Journal Article
Closed access
PDF file
KEK. Eatwell
K. Eatwell
The plasma concentration of 25‐hydroxycholecalciferol was measured in 13 adult Hermann's tortoises ( Testudo hermanni ), seven adult spur‐thighed tortoises ( Testudo graeca ) and two adult marginated tortoises ( Testudo marginata ) during 2004. They were healthy, of both sexes, and kept in captivity under natural unfiltered sunlight in southern England with no dietary sources of cholecalciferol. Blood samples were taken in March, June and August, and the concentration of 25‐hydroxycholecalciferol did not vary significantly with the seasons. However, the concentrations in the female tortoises were always significantly lower than in the males.


1 June 2020 in Veterinary Record
Verified
Journal Article
Open access
PDF file
MLMartyn Lewis
Martyn Lewis
JBJonathan Bouvard
Jonathan Bouvard
KEKevin Eatwell
Kevin Eatwell
GCGeoff Culshaw
Geoff Culshaw
Introduction Corn snakes are a very common pet reptile species, yet there is an absence of evidence-based literature standardising collection of ECG or detailing ECG deflection morphology in the normal animal. The authors describe a well-tolerated, reproducible technique and detail the cardiac cycle in terms of lead 2 equivalent waveforms and intervals. Animals 29 adult corn snakes. Materials and methods This prospective study evaluated, under species-appropriate, standardised conditions, a technique for producing standard six-lead ECG tracings. Lead 2 equivalent cardiac cycles were described in detail and statistically analysed for sex, weight, length, heart rate and mean electrical axis. Results High-quality tracings demonstrated common ECG characteristics for this species, including no Q, S or SV waves, prolonged PR and RT intervals, rhythmic oscillation of the baseline, short TP segments, and a right displaced mean electrical axis. An influence of sex, weight or length on heart rate and mean electrical axis was not identified. Conclusions To the authors’ knowledge, this is the first study to describe a standardised technique for recording ECG in significant numbers of normal corn snakes. Ranges have been provided that may be of diagnostic value or form the basis for future development of reference intervals for this species.

26 July 2023 in Veterinary Radiology & Ultrasound
Verified
Journal Article
Open access
CCChavdar Chernev
Chavdar Chernev
TPTessa Procter
Tessa Procter
IIIngrid Isaac
Ingrid Isaac
BKBronwyn Koterwas
Bronwyn Koterwas
KEKevin Eatwell
Kevin Eatwell
TSTobias Schwarz
Tobias Schwarz
Computed tomography is commonly utilized for investigation of rabbits, and more recently, for evaluating abdominal pathology. The spleen, however, is an often-overlooked organ, with limited information published. The aims of this retrospective, observational, study were to document the visibility, size, and shape of the normal rabbit spleen and potential correlations with signalment. Institutional imaging archives were reviewed for diagnostic-image-quality abdominal CT studies of rabbits. . In 115 cases, the inclusion criteria were met. Pre- and postcontrast CT studies were evaluated by two reviewers for visibility of the spleen. For precontrast CT images, the interrater agreement for identification of the spleen was fair. For postcontrast CT images, interrater agreement was moderate . There were significantly more spleens clearly identified on postcontrast studies compared with precontrast CT . Splenic location, volume, shape, X-ray attenuation, and length were measured, and the splenic-volume-to-body-weight ratio was calculated. The mean splenic volume was 1 mL (range 0.2-3.9 mL), mean length 40 mm (range 20-61 mm), mean attenuation (precontrast CT 80 HU and postcontrast CT 320 HU), and mean splenic volume/body weight ratio was 0.5 mL/kg (range 0.17-1.2 mL/kg). There was a significant relationship between splenic volume and body weight , which was weakly positively correlated . There was no correlation between splenic volume, age, and sex. The most commonly identified splenic shapes were "banana", "tongue", and "elephant trunk". The rabbit spleen can be identified on CT images, but more reliably on postcontrast CT images, which underlines the usefulness of contrast-enhanced CT in this species.